Laserfiche WebLink
DISTANCE SHALL BE EXHAUST FAN <br /> EQUAL TO CURB SECURE FAN TO CURB <br /> OUTS/DE DIMENSION WITH GALVANIZED <br /> PROVIDE TRANSITION SHEET METAL SCREWS <br /> FROM DUCT TO FAN FACTORY ROOF CURB WITH <br /> CURB FULL PERIMETER NEOPRENE CINCH BAND RIGID DUCTWORK <br /> PAD BETWEEN CURB AND UNIT. RECTANGULAR OR <br /> PRO VIDE OPEN OR CLOSED ROUND OPPOSED <br /> RESTRAINED SPRING <br /> V/BRA TION /SOLA TORS WHEN BLADE DAMPER <br /> 30' INDICA TED ON DRA WINGS. INSULA TED <br /> } SHEET <br /> 2X4 WOOD NA/LER CONTRACTOR SHALL VERIFY INSULA TED K METAL <br /> ROOF MEU,5R Al — ROOF PITCH AND PROVIDE FLEX/BLE <br /> A SL OPED ROOF CURB /F DUCT PLENUM <br /> ,�^� ©2017 STARBUCKS COFFEE COMPANY <br /> } REQUIRED <br /> ROOF NSb A T1CANT <br /> METAL DECK � METAL <br /> MOTORIZED BACKDRAFT STUD <br /> ,GOOFJOIST- � � � ��� DAMPER FRAMING STARBUCKS COFFEE <br /> FLEXIBLE CONNECTION ROUND TO <br /> OVAL TRANS/T/ON FLEX/BLE CAS/NG COMPANY <br /> ANGLE FRAME AND WIRE (50'-0- FLEX/BLE 2401 UTAH AVENUE SOUTH <br /> MAX/MUM DUCTWORK SEATTLE,WASHINGTON 98134 <br /> LINEAR (206)318-1575 <br /> GYP. BD. CE/L/NG DIFFUSER WITH <br /> CONCEALED LOCK/NG RACK & THESE DRAWINGS AND SPECIFICATIONS ARE <br /> FASTENER PINCH OPERA TOR CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> ROOF EXHAUST FAN DETAIL PROPERTY OF STARBUCKS CORPORATION, <br /> 7CEILING DIFFUSER WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> THIS WORK. THEY SHALL NOT BE <br /> NOT TO SCALE REPRODUCED (IN WHOLE OR IN PART), SHARED <br /> WITH THIRD PARTIES OR USED IN ANY MANNER <br /> LINEAR DIFFUSER DETAIL SOCKET WRENCH ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> 4 PROJECT WITHOUT THE PRIOR WRITTEN <br /> ROOF TOP UN/T. REFER TO CONSENT OF STARBUCKS CORPORATION. <br /> SCHEDULES AND NOT TO SCALE REMOTE VOLUME THESE DRAWINGS AND SPECIFICATIONS ARE <br /> SPEC/F/CA TIONS FOR SIZES INTENDED TO EXPRESS DESIGN INTENT FORA <br /> AND ADDITIONAL DAMPER CONTROLLER PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> REQUIREMENTS SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> NOT REFLECT ACTUAL SITE CONDITIONS. <br /> NOT TO SCALE NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> NOR LIABILITY TO THE OTHER(EXCEPT STATED <br /> ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> FULLY EXECUTED BY BOTH PARTIES. <br /> FACTORY ROOF CURB W/TH <br /> FULL PER/METER INSULA TED <br /> ARCHITECT OF RECORD <br /> NEOPRENE PAD BETWEEN FLEX/BLE <br /> RECTANGULAR OR me architecture <br /> IN, CURB AND UNIT PROVIDE ROUND TO DUCT ROUND OPPOSED CD <br /> g L <br /> OPEN OR CL OSED TO 0 VAL R/G/D DUCTWORKa' <br /> RESTRAINED SPR/NG TRANS/TION BLADE DAMPER U w <br /> V/BRA TION /SOLA TORS _ <br /> U U <br /> WHEN /ND/CA TED ON Cz <br /> DRA WINGS FLEX/BLE Cn <br /> " = DUCTWORK <br /> GAS PIP/NG (IF APPLICABLE). 111 Pacifica,Suite 280, Irvine,CA 92618 <br /> GYP. BD. CAS/NG — <br /> P: 949.553.1117 F:949.474.7056 <br /> PROVIDE GAS COCK, UN/ON, CINCH BAND CLAMP <br /> AND DIRT LEG. PRO VIDE WALL <br /> ENGINEER STAMP <br /> THROUGH THE BASE o l;E S S i <br /> PENETRA TION WHEN SPECIFIED P R ROY S CNq� <br /> C <br /> tl;l <br /> FLEX/BLE CAS/NG �4z- �o�y titi F <br /> A A INSULA TED <br /> INSULA , 00 SHEET (50—D MAX/MUM) <br /> — C� r Z <br /> w No. M33299 m <br /> ME ROOFTOP UN/T <br /> ���� META L �� LOCK/NG RACK & <br /> L/NEAR PLENUM / V / / I PINCH OPERA TOR <br /> ROOF JOIE CONDENSATE DRAIN PIPE � / / / I � I <br /> SIZE SHALL BE NO LESS DIFFUSER WITH I / I ® T FCHgN SCP <br /> ROOF MEhlf&,�?ANE THAN DRAIN CONNECTION CONCEALED METAL �� I 1 j j fo I MOUNT/NG9TF pF cA F09L <br /> I ; \ j <br /> FLEX/BLE CONNECT/ON �` ON UN/T. REFER TO FASTENER STUD o BRACKET <br /> PLUMBING PLANS FOR FRAM/NG p ���L�— -� i' Date. 03/24/2020 <br /> RETURN A/R DUCT ROUT/NG, SIZE, AND <br /> SUPPL Y A/R DUCT DISCHARGE LOCA TION OF <br /> S• CONDENSA TE L/NEAR SLOT <br /> ND <br /> DIFFUSER WITH <br /> 1. PROVIDE THROUGH CURB ELECTRICAL CONNECTIONS. NO ROOF PLENUM BOX <br /> PENETRA TIONS OF ELECTRICAL CONDUITS WILL BE ACCEPTABLE. LINEAR DIFFUSER DETAIL <br /> 2. DUCT SMOKE DETECTOR SHALL BE MOUNTED AND INSTALLED <br /> PER LOCAL CODES. 5 <br /> NOT TO SCALE SOCKET WRENCH <br /> TYPICAL ROOF T UNIT DETAIL MAX. OF 12" TO 270-275—ML 270-275—PH <br /> 8 BRANCH CONNECT/ON EXTENDED OPTIONAL EXTENDED w O <br /> NOT TO SCALE UNLESS NOTED OTHERWISE CONTROL SHAFT CONTROL SHAFT J N <br /> FOR ADJUS TMEN T <br /> "ICE TONG" STYLE WITH PH/LL/PS > (y) <br /> GALVANIZED SHEET DIFFUSER SCREWDR/VER Q Q Q <br /> METAL DUCT (C V <br /> USE <br /> RIGID GAL VAN/ZEDW w - z <br /> 90 DEGREE ELBOW O <br /> REMOTE Q U ❑ U <br /> WOOD NA/LER ROOFTOP NIT I VOLUME A Z _ Q <br /> 00 o U 2 <br /> LL I— Q <br /> A TTA CH TO CURB.• UNIT BASE RAIL INOT TO SCALE U — U V <br /> (4) #10 1/2" TEK SCREWS OR LIFTING LUG wwr , <br /> VOLUME DAMPER LOCA TED METAL STRAP CLAMP 3 U --3 O O <br /> 6" WIDE 16 GAUGE GAL V. A TTA CH TO UNI T- /N ACCESS/BLE L OCA TION. (TYPICAL) 2 PLACES <br /> Q <br /> PLATE, BENT TO SHAPE (4) X10 1/2 TEK SCREWS PROVIDE ACCESS DOOR OR FIBERGLASS 00 U) <br /> CABLE OPERATOR /F NOT INSULA TION PER INSULA TED FLEX/BLE DUCT <br /> FA CTOR Y CURB.- 14" MIN. HEIGHT, 3/4" MAX/MUM A CCESSIBLE. SPEC/F/CA TIONS ( e <br /> 16 GAUGE, SQUARE WITHIN 1 8 ON 3 CANT STRIP (MIN. 2, MAX. 5, NO MORE <br /> / OPPOSED BLADE THAN ONE 90 BEND) SEISMIC BRACING AND SIZING STORE #: 5470 <br /> DIAGONAL MEASUREMENT, WITH A ROOF MEMBRANE DAMPER AT PROJECT#: 03030-052 <br /> MINIMUM OF 8" ABOVE TOP OF ROOF ROOF INSULA R ON DIFFUSER BRACE SIZING BRACING SP ACING CASEWORK CONCEPT: CORE <br /> 1 1/2" RIGID INSULA TION METAL DECKING TRANS/T/ON FFITTINGINSULATE DIFFUSER ISSUE DATE: CHECKSET 2-10-20 <br /> WELD ROOF CURB TO SUPPORT FRAME ROODla'-57 <br /> _'-5 PE ND BACK AND SEAL W/TH AS REQUIRED BRACE SIZE MAXIMUM PIPE SIZE MAXIMUM MAXIMUM PROGRAM MANAGER: M. DBREBIKA <br /> VAPOR BARRIER TAPE LENGTH HANGER SPACING BRACE SPACING* STORE DESIGNER: M. DBREBIKA <br /> STRUCTURAL SUPPORT AND FRAME SUPPL Y AIR DIFFUSER (SEE NOTE B) <br /> AS REQUIRED FOR FULL PER/METER I LE E D(D AP: N/A <br /> OF FACTORY CURB, WELD TO STRUCTURE I 2" x 2" x 3/16" ANGLE 6'-0" UP TO 1 1/2" 7'-0" NOT REQUIRED CHECKED BY: A. FELDMAN <br /> MCG PROJECT#: 18531 <br /> SEISMIC REQUIREMENT NOTES-. 2 1/8" x 2 1/8" x 3/16" ANGLE 8'-0" 2" 10'-0" NOT REQUIRED MCG PROJ. MANAGER: C. LEE <br /> A. A/R TERMINALS WE/GH/NG LESS THAN 20 POUNDS SHALL BE POS/Tl VEL Y A TTA CHED TO THE MCG P ROJ. SPECIALIST: SPARK <br /> MA/N RUNNER. 3" x 3" x 3/16" ANGLE 10'-0" 2 1/2" TO 3" 10'-0" 7'-0" <br /> B. A/R TERM/MALS WE/GH/NG BETWEEN 20 POUNDS AND 56 POUNDS SHALL HA VE TWO 12 Revision Schedule <br /> GAUGE HANGER WIRES CONNECTED FROM THE TERM/NAL TO THE STRUCTURE ABOVE AND 3 1/2" x 3 1/2" x 1/4" ANGLE 11'-6" 4" AND UP 10'-0" 10'-0" <br /> SHALL SE POS/T/VEL Y A TTA CHED TO THE MAIN RUNNER. THE HANGER WIRES MA Y BE SLA CK. Rev Date By Description <br /> AWES: <br /> 1. USE A MINIMUM OF (1) PLA TE PER SIDE OF UNI T. C. A/R TERMINALS WE/GH/NG MORE THAN 56 POUNDS SHALL HA VE INDEPENDENT SUPPORT FROM 4" x 4" x 1/4" ANGLE 13'—0" NOTES.• <br /> 2. PLA TE MUST BE PAINTED INHERE I T CONTACTS RAIL. THE STRUCTURE ABOVE. A. DUCTS WH/CH ARE LARGER THAN 6 SQUARE FEET /N <br /> J. USE (8) SCREWS TO SECURE PLA TE, NO SMALLER THAN #IOx 1/2' ' D. HANGER WIRES SHALL MEET THE SAME INSTALLATION REQUIREMENTS AS VERT/CAL SUSPENS/ONCROSS SECT/ON AREA SHALL BE BRACED LA TERALL Y <br /> 3 DIAM. PIPE 13'-0" TO 7'0" ON CENTERS WITH 2" x 2" x 3/16" ANGLE. <br /> 4. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF, AND COMPLIANCE WITH WIRES. 18'—0" *B. BRACING CAN BE OMITTED ON ALL PIPING SUSPENDED <br /> ALL LOCAL CODES. BY INDIVIDUAL HANGERS 12" OR LESS /N LENGTH FROM <br /> 5. CUT AND PATCH EXISTING ROOFING AS REQUIRED FOR NEW CURB INSTALLATION. THE TOP OF PIPE TO THE BOTTOM OF THE SUPPORT SHEET TITLE: <br /> 6. CURB SHALL BE SHIMMED LEVEL. PROVIDE TAPERED ROOF CURB IF REQUIRED. FOR THE HANGER. HVAC DETAILS <br /> 9 <br /> SEISMIC ROOF CURB DETAIL 6 TYPICAL DIFFUSER CONNECTION SEISMIC <br /> SEISMIC BRACE SCHEDULE <br /> 3Schnackel <br /> SCALE:AS SHOWN <br /> ===== <br /> NOT TO SCALE NOT TO SCALE NOT TO SCALE <br /> == engineers® SHEET NUMBER: <br /> NewYork a Omaha a La Angeles a Seattle®Honolulu <br /> 800-5810%3 w*wjdwmckeLwm <br /> F80 South Lake Avenue, Suite 640 Pasadena, CA 91101 M-5001 <br /> SE JOBO:181163 <br />