My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
1810
>
1600 - Food Program
>
PR0547120
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2021 4:35:14 PM
Creation date
10/1/2021 1:39:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547120
PE
1624
FACILITY_ID
FA0026728
FACILITY_NAME
STARBUCKS COFFEE #5470
STREET_NUMBER
1810
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
1810 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br /> A. FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE <br /> NOT NECESSARILY SHOWN. <br /> B. PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO �► <br /> START OF WORK TO REVEAL FULL SCOPE OF WORK. <br /> C. ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO <br /> CUSTOMERS. <br /> D. REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS <br /> UNLESS OTHERWISE NOTED. ©2017 STARBUCKS COFFEE COMPANY <br /> E. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL STARBUCKS COFFEE <br /> PLUMBING EQUIPMENT. COMPANY <br /> F. DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. 2401 UTAH AVENUE SOUTH <br /> SEATTLE,WASHINGTON 98134 <br /> G. REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. (206)318-1575 <br /> THESE DRAWINGS AND SPECIFICATIONS ARE <br /> H. COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. PROPERTY OF STARBUCKS CORPORATION, <br /> REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> REQUIREMENTS. THIS WORK. THEY SHALL NOT BE <br /> REPRODUCED(IN WHOLE OR IN PART), SHARED <br /> WITH THIRD PARTIES OR USED IN ANY MANNER <br /> I. CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER BEFORE THE TIME THAT ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> THE FILTER SYSTEM IS TO BE STARTED UP. PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. <br /> THESE DRAWINGS AND SPECIFICATIONS ARE <br /> J. VERIFY PROPER WATER SYSTEM WITH WATER TEST RESULTS. INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> K. ALL PLUMBING CLEANOUT CANNOT BE COVERED. PLUMBING CLEANOUT MUST SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> NOT REFLECT ACTUAL SITE CONDITIONS. <br /> _______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ _____________________________ _______________________________________L. HAVE EASY ACCESSIBILITY. <br /> NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> NOR LIABILITY TO THE OTHER EXCEPT STATED <br /> L. PROVIDE ACCESS PANELS FOR ELECTRICAL, PLUMBING AND HVAC AS SPECIFIED ABOVE)UNTIL A WRITTEN AGREEMENT IS <br /> BY CODE OR AS DICTATED BY THE LANDLORD. FULLY EXECUTED BY BOTH PARTIES. <br /> ARCHITECT OF RECORD <br /> mcg architecture <br /> KEYED NOTES: <br /> 12 4" VTR - - <br /> C z <br /> Lz <br /> C2� <br /> L <br /> C <br /> 1 <br /> THIS SPACE IS RESERVED FOR ELECTRICAL EQUIPMENT. NO PIPING SHALL PASS <br /> __ BELOW, ABOVE, OR AROUND ELECTRICAL EQUIPMENT. PROVIDE CODE REQUIRED <br /> _______________ ______________ MINIMUM CLEARANCE ABOVE ELECTRICAL EQUIPMENT ACCESS SPACE. 111 Pacifica,Suite 280,Irvine,CA 92618 <br /> I » 11 2 2"IIVASTE DOWN, 1 1/2" VENT UP. P 949 5531117 F 949 474 7056 <br /> I�3 3 <br /> #� ENGINEER STA <br /> @18029 ------------------------------------------------------------------ <br /> 1 ®, o 2" INDIRECT DRAIN FROM FRONT PORTION OF SINK TO FLOOR SINK. MP ROFESS,o <br /> vi rn CO �. I � I � <br /> 3 Q Hq <br /> N N N / " �p y EtOY SCy C <br /> 1 2 INDIRECT DRAIN FROM BACK PORTION OF SINK TO FLOOR SINK. <br /> Ij-�- t� � 10594 4 1 <br /> T T 2 1 94 NF - <br /> 1' INDIRECT INSULATED DRAIN FROM ICE BIN TO FLOOR SINK " rn <br /> Z <br /> T I <br /> 1 105 <br /> I 3, <br /> O No 3 <br /> 1 „ <br /> 1/2" <br /> 3, <br /> _ <br /> 6 <br /> 3/4" INDIRECT DRAIN FROM ESPRESSO MACHINE TO FLOOR SINK <br /> 13 Fc G <br /> CO' D D o - -- 7 1 INDIRECT DRAIN FROM UTENSIL RINSE SINK TO FLOOR SINK. 9TF <br /> OF CAL\ <br /> F <br /> ���RTU-1 I � 1 1/4 � �13 �1�2„ � � 1 1/2 �4 13 �1/2„ 14 � � " <br /> rn 5-TON - O � U ������� 1 INDIRECT DRAIN FROM IN-COUNTER RINSER TO FLOOR SINK. <br /> N I O <br /> ,3 I I <br /> RTU-2 I RTU-3 r \ Date. 03/24/2020 <br /> » <br /> o I 6-TON I 2 I 6 F 0 L L -TON I `� � _ _________ ____ g 1" INDIRECT DRAIN FROM DRIP TRAY TO FLOOR SINK. <br /> O <br /> I I I - 0 1p co <br /> 1 INDIRECT DRAIN FROM ICE MACHINE TO FLOOR SINK. <br /> I------------------------------------------------------- 187430 I ( I I ( I - -- - CONNECT TO EXISTING SANITARY SEWER LINE OF EQUAL OR GREATER SIZE. <br /> =/ I / ( \ I I / ( I O VERIFY IN FIELD FOR EXACT LOCATION, SIZE, AND INVERT. <br /> cV ___________________________________________________________________________________________________________________________________________________ <br /> o ; <br /> ,. L_ � 12 UP TO 4 VENT THROUGH ROOF. INSTALL VENT THROUGH ROOF A <br /> rn o = `� 2 MINIMUM DISTANCE OF 10'-0" FROM ALL FRESH AIR INLETS AND <br /> co Ln \ <br /> Ln cc w '� ,f 3„ , : _________ ________� BUILDING OPENINGS. <br /> O <br /> r, � , ., 3 W <br /> N <br /> - ROUTE THE CONDENSATE PIPING ON THE ROOF FROM THE ROOFTOP UNIT TO <br /> .. ... ___.. .. 13 In <br /> - THE RESTROOM LAVATORY TAILPIECE. THE CONDENSATE SHALL BE CONNECTED w <br /> » '� TO THE ROOFTOP UNIT IN ACCORDANCE WITH THE MANUFACTURER'S <br /> RECOMMENDATIONS. VERIFY CONDENSATE REMOVAL REQUIREMENTS WITH LOCAL Q <br /> � N JURISDICTION PRIOR TO INSTALLATION. IF CONFLICTS OCCUR, NOTIFY THE � � V <br /> co o ARCHITECT/ENGINEER IMMEDIATELY. W U <br /> rn L.L <br /> ; <br /> C14 <br /> I <br /> 3 4 - -°- - 14 FURNISH AND INSTALL 3 DIAMETER PVC COMBUSTION AIR AND EXHAUST FROM — O <br /> - 0 00 � <br /> � THE WATER HEATER TO THE EXTERIOR. FURNISH AND INSTALL CONCENTRIC VENT Z — Q � <br /> _ rn <br /> N - ` - KIT. THE INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S <br /> o U U <br /> RECOMMENDATIONS AND ALL APPLICABLE LOCAL AND STATE CODES COORDINATE <br /> --------------------------------------------- 19742 ,6 1:9742 6 - - W W <br /> 0 <br /> II - <br /> 1 - THE MAXIMUM ALLOWABLE EXHAUST AND VENT LENGTHS WITH THE MANUFACTURERS � <br /> -- _ REQUIREMENTS. INSTALL CONCENTRIC VENT THROUGH ROOF A MINIMUM DISTANCE <br /> O <br /> r <br /> 19277 8 Q 00 <br /> O <br /> -__ OF 15'-O" FROM ALL FRESH AIR INLETS AND BUILDING OPENINGS <br /> - - STORE #: 5470 <br /> / - PROJECT# 03030-052 <br /> 19277 8 '1 1 2" <br /> ...::::: .:::: <br /> 0 <br /> U <br /> � CASEWORK CONCEPT: CORE <br /> ____��� _____��� ____uuuu ___nano ____ohms ____nnun ____nnuu - 0-20 <br /> _ -- --- -- ISSUE DATE• HE K ET 2 1 <br /> -..... <br /> . RM. DBREBIKA <br /> PROGRAM MANAGE <br /> `; BREBIKA <br /> _ ..o,,,.. , IGNER. <br /> STORE DES M D <br /> MCG PROJECT#: <br /> ._ _____ .�� - � � - MCG PROJ. MANAGER: C. LEE <br /> -- -_ -- ------- MCG PROJ. SPECIALIST: SPARK <br /> Revision Schedule <br /> Rev Date By Description <br /> SHEET TITLE: <br /> PLUMBING WASTE VENT PLAN PLUMBING WASTE AND <br /> U G S & <br /> 1 Scale: 1/411= 1 1-011 N VENT PLAN <br /> LEGEND SCALE:AS SHOWN <br /> == SChnackel <br /> EXIST/NGe <br /> � m <br /> NEW WORK NewYork m Omaha m las Aeles m Seattle Honol�duu® SHEET NUMBER: <br /> ng <br /> ® NEW TO EX/S T/NG CONNEC T/ON X581-0963 wwwschnadae�.Qom <br /> 80 South Lake Avenue, Suite 640 Pasadena, CA 91101 P-1 102 <br /> SE JOEW: 181103 <br />
The URL can be used to link to this page
Your browser does not support the video tag.