Laserfiche WebLink
NOTE: SYMBOL LEGEND <br /> DETECTOR LOOPS ARE REQUIRED AT <br /> THE ORDER CONFIRMATION UNIT AND <br /> AT EACH OF THE DRIVE-THROUGH WINDOWS <br /> DETAIL DESCRIPTION <br /> TOGGLE SWITCH - SINGLE POLE HUBBELL #1221-1 w <br /> D PUSHBUTTON SWITCH Q <br /> DATA CABLE <br /> (TYPICAL TO (2) ORDER STATIONS) 1 g POWER SOUND STUB UP (b SINGLE RECEPTACLE HUBBELL #5361-1 <br /> ABOVE CEILING � <br /> 1" CONDUITS UNDERGROUND TO (TYP. OF 3) Q #5362-1 <br /> DUPLEX RECEPTACLE HUBBELL <br /> ORDER CONFIRMATION UNIT (O.C.U.) 208V RECEPTACLE HUBBELL 208V, 10 - #5352-1 zo <br /> (6 TOTAL) N 208V, 30 - #8420 N <br /> 0 " TELEPHONE OUTLET WITH BUSHED HOLE COVERPLATE <br /> ° u 18 A.F.F. o o • <br /> 0 <br /> xxx B1, [ B-15 O JUNCTION OR GANG BOX m <br /> B- g B1 (TIE) 0 Q CABLE TELEVISION OUTLET o <br /> o Y <br /> B-30B-39 O7 BUZZER / BELL w <br /> - L) /Plo <br /> �k+g F.F. B-41 A_W3 ir-6 B-43 B-40,42 B-17 REQUIRED J-BOX & RECEPTACLE FOR REAR DOOR ALARM <br /> B-36 B-44,46,48 B-32 FOR CABLE TV & PLASMA MONITOR T❑ TRANSFORMER <br /> NOTE: NO ELECTRICAL CONDUITS B-45,47 CENTER ON WALL @ 84" A.F.F. (VERIFY) <br /> TO BE PLACED WITHIN HOOD AREA. <br /> 13 PANEL "D" 0 <br /> _ _ ___ 7-71 ABBREVIATIONS } <br /> tAK uuuR "A" "B" T " ® m <br /> ELEC. PANELS +84 z <br /> O ALARM A.F.F. A-3 CONDUIT RUN WITH ARROW DENOTING HOMERUN. 3: a <br /> 23 BB=g 1 SUBSCRIPT INDICATES PANEL AND CIRCUIT NO. Q <br /> B_4 0° J-BOX/RECEPT. TO BRING DOWN GROUND CONDUCTOR REQUIRED IN ALL CONDUITS o <br /> POWER TO DECOR LAPTOP HIGH TABLE BUT NOT INDICATED oz <br /> 22 BB=2 COORDINATE LOCATION/REQUIREMENTS 16 OO A-W1 N WITH THE DECOR SUPPLIER GFCI GROUND FAULT CIRCUIT INTERRUPTING <br /> REFER TO SHEET E-4 W.P. WEATHERPROOF <br /> W P e❑ � I 12 FOR P.O.S. SYSTEMS <br /> +48" 3 ® ELECTRICAL INFORMATION O A.F.F. ABOVE FINISHED FLOOR. o <br /> +72" A.F.F. B-14 I.G. ISOLATED GROUND <br /> B-56.5813 <br /> = B-34 00 <br /> 0 <br /> F-1 F-1 \ � B-33 00� <br /> 17 B-31 <br /> o KEYED NOTES - PLAN : <br /> z <br /> +60" A.F.F. B-60,62 1. FRYER HOOD: PRE-WIRED (WITH RECEPTACLES BY HOOD MANUFACTURER. <br /> ELECTRICAL CONTRACTOR TO MAKE CONNECTION AT JUNCTION BOX AT THE TOP OF w O <br /> Ln <br /> THE HOOD. <br /> B-64,66,68 u rn <br /> NOTE: BROILER HOOD: PRE-WIRED (WITH DUPLEX RECEPTACLES) BY HOOD MANUFACTURER. > � Ln <br /> 1 Ln <br /> TRANSFORMER PAD TO BE LOCATED O 20 21 WP ELECTRICAL CONTRACTOR TO MAKE CONNECTION AT JUNCTION BOX AT THE TOP OF Lf L <br /> AS CLOSE AS POSSIBLE TO BUILDING W.P. UP TO C.U. O GFCI THE HOOD. ELECTRICAL CONTRACTOR TO PROVIDE RECEPTACLE AND COVER PLATE cn � � ro <br /> ON ROOF B_29 FOR THE OVEN AND BROILER BASED ON EQUIPMENT SELECTED. O Q � <br /> 2. ELECTRICAL CONTRACTOR TO RUN CONDUITS AND WIRE THROUGH THE EQUIPMENT z <br /> 09 B-17 +18 CHASE AND CONNECT TO CIRCUITS PROVIDED IN THE JUNCTION BOX BY EQUIPMENT ool � � O OI <br /> MANUFACTURER. <br /> WP/GFCI +18" A.F.F. NOTE: 3. VERIFY POWER REQUIREMENTS FOR SELECTED WATER HEATER. � ¢ W <br /> FUTURE SOLAR EQUIPMENT B-19 REFER TO OFFICE ELEVATIONS, <br /> 4. REAR DOOR ALARM: "MONITOR 4000" BY SECURITY PRODUCTS, INC. OR APPROVED � <br /> SHEET E-4, FOR LOCATIONS AND z O <br /> AREA. (CONDUITS TO RISE (TIE) CIRCUITING OF PHONE JACKS EQUAL. MOUNT SIMPLEX RECEPTACLE FOR POWER SUPPLY 6" ABOVE CEILING. ¢ < � Ld <br /> TO ROOF FROM HERE). AND RECEPTACLES IN OFFICE. 5. PERMANENTLY CONNECTED KITCHEN EQUIPMENT NOT SUPPLIED WITH ON/OFF UNIT W � Z <br /> B-28 4°° 24 SWITCH (WHICH IS PART OF THE APPLIANCE) TO SERVE AS A DISCONNECTING MEANS. Q Ld O <br /> 42" A.F.F. UNIT SHALL BE SUPPLIED WITH A DISCONNECT AS PER N.E.C., FURNISHED BY THE _ Lo > = <br /> ELECTRICAL CONTRACTOR. N J a- <br /> 42" A.F.F. 6. G.C. TO VERIFY ELECTRICAL REQUIREMENTS FOR FIRE SUPPRESSION SYSTEM AND <br /> AUTO-SELENOID GAS SHUT-OFF VALVE. <br /> L)7 <br /> 19 8 W.P. 7. RUN 2" CONDUIT TO MANAGERS OFFICE FOR CABLE TV. <br /> GFCI 8. HEAT TAPE IS PROVIDED BY THE WALK-IN BOX MANUFACTURER AND INSTALLED BY <br /> vo B-8 THE ELECTRICAL CONTRACTOR. CONTRACTOR SHALL COORDINATE INSTALLATION AND <br /> SUPPLY 120V CIRCUIT AND RECEPTACLE AS DIRECTED BY BOX MANUFACTURER. <br /> B-1372"LF. ^� O 9. DIGITAL MENU BOARDS (VERIFY 3 OR 4 BOARD INSTALLATION): PROVIDE (1) DUPLEX <br /> RECEPTACLE FOR 120V CIRCUIT AND (1) P-RING FOR DATA CABLE AT EACH MENU <br /> BOARD SCREEN. REFER TO DETAIL, SHEET E-4. 6, <br /> 10. STAINLESS STEEL SERVICE CHASE TO CEILING FURNISHED BY THE EQUIPMENT <br /> ELECTRICAL CONTRACTOR EC - GENERAL NOTES: MANUFACTURER. <br /> ( ) 11. CONTRACTOR SHALL OBTAIN WIRING DIAGRAM FROM THE WALK-IN BOXCA Q ro <br /> A. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES AND STANDARDS. MANUFACTURER AND INSTALL AS DIRECTED. U"' <br /> B. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN/NOTED POWER PLAN 12. CONTRACTOR SHALL COORDINATED EQUIPMENT INSTALLATION WITH THE EQUIPMENT QJ �Lo <br /> MANUFACTURER'S INSTALLATION PERSONNEL. �••� ti <br /> OTHERWISE. U <br /> SCALE: I/4" = I -O 13. PRE-WIRED BRANCH CIRCUITS DISCONNECTED FOR SHIPMENT TO BE RE-CONNECTED � �, <br /> C. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEMS AS SHOWN/NOTED ON THE BY GC PER MANUFACTURER'S INSTALLATION SPECIFICATIONS. Q • 'U o c) <br /> DRAWINGS AND PER OTHER APPLICABLE DRAWINGS/INSTRUCTIONS. REFERENCE MECHANICAL DRAWINGS. 14. ELECTRICAL CONTRACTOR TO PROVIDE CORD AND PLUG AND WIRE TO BROILER BASED D <br /> D. WIRE SIZE SHALL BE #12 (MINIMUM) UNLESS OTHERWISE NOTED. WIRE SIZES SMALLER THAN #6 AWG SHALL BE THHN/THWN. #6 AWG WIRE AND ON EQUIPMENT SELECTED. C•) X <br /> LARGER SHALL BE THW, UNLESS NOTED OTHERWISE. 15. CONTRACTOR SHALL COORDINATE CONDUIT RUN BETWEEN FREEZER/COOLER O o <br /> E. WIRE (CONDUCTOR) COLORS SHALL BE AS PER APPLICABLE CODES. EVAPORATORS AND ROOF-TOP REFRIGERATION UNIT WITH THE MANUFACTURER'S <br /> F. ALL CONDUCTORS SHALL BE COPPER. FURNISHED WIRING HARNESS. r4 C/11 c:, <br /> 16. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES INSIDE WALL ® 48" A.F.F. Lu oD <br /> G. ALL CONDUCTORS SHALL BE RUN IN CONDUIT, EXCEPT LOW VOLTAGE CONTROL AND COMMUNICATIONS CABLES. WITH STUB-UPS TO CEILING FOR AMEREX PULL STATION AS REQUIRED BY EQUIPMENT U <br /> Lo <br /> H. ALL MATERIALS SHALL BE UL APPROVED. SUPPLIER. ti <br /> I. ALL BRANCH CIRCUITS, EXCEPT INTERIOR LIGHTING, EXTERIOR BUILDING SIGNS, PARAPET LIGHTING AND SOFFIT LIGHTING TO HAVE A GREEN 17. SMOKE DETECTOR ALARM PANEL: REFER TO SHEET M-1 FOR LOCATION OF A/C <br /> UNITS SMOKE DETECTORS. z o <br /> EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER NEC 250-122. _j co <br /> 18. (3) 1"0 CONDUIT TO BASE OF DRIVE-THROUGH ORDER STATION FOR DRIVE-THROUGH p� <br /> J. PVC (SCHEDULE 40) PERMITTED BELOW SLAB AND BELOW GRADE ONLY. COMMUNICATIONS SYSTEM, SOUND, DATA AND POWER. U-i <br /> K. IT IS INTENDED THAT AN EQUIPMENT GROUND CONDUCTOR (GREEN) SHALL BE RUN IN POWER CIRCUIT CONDUITS WHETHER OR NOT THE 19. 6" BELOW CEILING FOR CONDENSATE DRAIN LINE TAPE HEATER. z Lu <br /> CONDUIT IS PVC. 20. TO MASTER RELAY PANEL. REFER TO SHEET E-5 0 <br /> L. ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRING. 21. MANUAL ON-OFF CONTROL PANEL. REFER TO SHEET E-5 0 <br /> M. NEW TYPEWRITTEN PANEL DIRECTORY SHALL BE FURNISHED AFTER JOB IS COMPLETED REFLECTING ALL AS BUILT CONDITIONS. 22. MASTER CONTACTOR PANEL. REFER TO SHEET E-5 AND NOTE #23, BELOW. <br /> 23. SWITCH GEAR OPTION #1: <br /> N. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. RECESS ELECTRICAL CONTACTOR PANEL & PANELS 'A', 'B', & 'M' IN FURRED OUT <br /> O. ALL DATA EQUIPMENT TO BE FED BY A DEDICATED CIRCUIT WHICH CONSISTS OF A POWER CIRCUIT THAT FEEDS THIS TYPE OF EQUIPMENT ONLY WALL ADJACENT TO EXTERIOR FRAMING. G.C. TO VERIFY PANEL SIZES PRIOR TO <br /> WITH A SEPARATE GREEN GROUNDING CONDUCTOR CARRIED ALL THE WAY BACK TO THE PANEL TO BE CONNECTED TO THE GROUNDING FURR-OUT TO INSURE ADEQUATE SPACE. <br /> SYSTEM. SWITCH GEAR OPTION #2: <br /> P. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. HILL PHOENIX INTEGRATED WALL UNIT INCLUDES PANELS 'A', '13% 'M' AND MASTER <br /> CONTACTOR PANEL IN ONE CABINET. UNIT TO BE SURFACE MOUNTED ON 4" HIGH <br /> Q. EC SHALL VERIFY INTERIOR DECOR THEME TO BE USED AND COORDINATE WITH SAID THEME. CONCRETE CURB. REFERENCE SHEET E-3 AND E-5 FOR ADDITIONAL INFORMATION. <br /> R. EC SHALL INSTALL AND CONNECT WIRING TO ALL SIGNS. 24. PROVIDE VISUAL STROBE ALARM MOUNTED AT 80" A.F.F. TIE TO H.V.A.C. SMOKE <br /> S. EC TO COORDINATED ROUGHING-IN TO ALL EQUIPMENT WITH EQUIPMENT SUPPLIER PRIOR TO INSTALLING CONDUITS. 20A N.FALARM SYSTEM. ���1EER * bf <br /> . <br /> T. ALL CONDUIT RUNS TO KITCHEN EQUIPMENT SHALL BE RUN ABOVE CEILING. DISCONNECT x 0 a' o <br /> w y» o <br /> U. MAINTAIN 12" CLEARANCE BETWEEN P.O.S. COMMUNICATION CONDUITS AND LIGHTING FIXTURES AS WELL AS POWER CONDUITS.. o x� e� o ? <br /> V. CUTTING AND NOTCHING OF 2x4 BEARING WALL FRAMING NOT TO EXCEED 7/8". BORING HOLES IN 2x4 BEARING WALL FRAMING NOT TO EXCEED 2UD oLA <br /> W. ALL 120V, 20A OUTLETS IN THE FOOD PREP AND "WET"AREAS SHALL BE GROUND FAULT INTERRUPT TYPE. O EF-1 -2 �� o z <br /> WP/GFCI © © p °' <br /> WP WP <br /> ELECTRICAL CONTRACTOR (EC) - H.V.A.C.: N <br /> A. THE EC SHALL FURNISH AND INSTALL PITCH PANS FOR POWER AND CONTROL WIRING AND TO MAINTAIN 12" MINIMUM CLEARANCE FROM BACK A-M1416 A-M1315 0 <br /> PANEL OF AIR CONDITIONING UNITS. . . 11 <br /> B. EC SHALL INSTALL ALL LOW-VOLTAGE CONTROL WIRING FOR ALL AIR CONDITIONING UNITS AND FANS. COORDINATE AIR CONDITIONING AND o RTU-2 A-M1,3,5 KEYED NOTE - ROOF. <br /> ELECTRICAL PLANS. OO <br /> C. EC SHALL FURNISH AND INSTALL DISCONNECTS FOR AIR CONDITIONING UNITS. ® 11 TU-3 WP o- 10 9 R "{' WP O1 OPTIONAL WEATHERPROOF OUTLET 30" A.F.R. FOR <br /> D. EC SHALL USE A MINIMUM OF 4'-6" SEALTITE FLEXIBLE CONDUIT WHEN WIRING KITCHEN HOOD EXHAUST FANS ON ROOF SO THAT FANS MY BE 10 9 10 9 TV VIDEO CAMERA. RUN CONDUIT TO BLDG. INT., <br /> REMOVED FROM CURBS AND PLACED ON ROOF FOR CLEANING EXHAUST DUCTWORK. A-M8.10.12 WP VERIFY SIZE AND LOCATION WITH OWNER. w <br /> E. IF REQUIRED BY LOCAL CODE, EC SHALL PROVIDE COMPONENTS -AUDIBLE AND VISUAL ANNUNCIATORS AND SINGLE-GANG RECEPTACLES TEST WP W.P. o-° 7 RTU-1 11 Q Z <br /> STATIONS WITH GREEN AND RED LIGHT INDICATORS. EACH KITCHEN UNIT WILL BE EQUIPPED AND THE FIRE AND MECHANICAL INSPECTORS WILL B-61.63 WP 3 A-M2.4.6 2 REMOTE FREEZER COMPRESSOR CONDENSING UNIT. CHASE - Q <br /> DETERMINE SUITABLE LOCATION FOR TEST STATIONS. ANNUNCIATORS AND TEST STATION WILL BE LOOPED IN THE CIRCUITRY OF THE SMOKE Of,, F10 9 A-M7.9.11 3 REMOTE COOLER COMPRESSOR CONDENSING UNIT. ELECTRICAL u <br /> DETECTION DEVICES. WIRING WILL BE SUPPLIED AND COMPLETED BY THE EC. WP 2RTU-4 4 TO FREEZER EVAPORATOR. ENGINEERING <br /> B-55.57.59 11 N <br /> ELECTRICAL CONTRACTOR (EC) - KITCHEN EQUIPMENT: 30A N.F. 5 TO COOLER EVAPORATOR. o Q <br /> A. EC TO PROVIDE AND INSTALL RECEPTACLES, CAPS AND CORDS AS REQUIRED. CAPS AND CORDS ARE TO BE INSTALLED ACCORDING TO THE ® DISC. B-19 (TIE) 6 STUB-UP CONDUIT ADJ. TO ROOF CURB AND PROVIDE ��F ESS/0/1/, o V) <br /> MANUFACTURER'S INSTRUCTIONS. SEAL TIGHT CONNECTION TO DISCONNECT WITH Q 9 N <br /> B. EC TO CONNECT ELECTRICAL SERVICE DIRECTLY TO EQUIPMENT ACCORDING TO THE MANUFACTURERS'S INSTRUCTIONS. O SUFFICIENT SLACK TO ALLOW REMOVAL OF FAN FOR ��� \� V . <br /> W <br /> C. EC TO RECONNECT ELECTRICAL CIRCUITS ON PRE-WIRED EQUIPMENT DISASSEMBLED FOR SHIPMENT. ��EF-3 SERVICING. <br /> D. WHERE EQUIPMENT IS NOT PRE-WIRED, EC TO CONNECT THE ELECTRICAL SERVICE AND PROVIDE INTER-WIRING AS REQUIRED. <br /> 7 FOR CONTINUATION, SEE LIGHTING PLAN, SHEET E-1. � p Um� <br /> E. WHERE RECEPTACLES ARE PROVIDED WITH THE EQUIPMENT, EC TO PROVIDE AND INSTALL ELECTRICAL SERVICE DOWN FROM ABOVE THROUGH 8 DOWN TO ICE MACHINE. w -9532 " �� U, Z <br /> THE SERVICE CHASE PROVIDE WITH THE EQUIPMENT. 1 1. ^ o <br /> F. KITCHEN EQUIPMENT SUPPLIER DRAWINGS INCLUDE ONLY THOSE RECEPTACLES REQUIRED FOR SPECIFIC KITCHEN EQUIPMENT. REFER TO THE 9 SEE ELECTRICAL RISER SHEET E-3 FOR ELECTRICAL `\ s - � w ap o <br /> ARCHITECTS/ENGINEERS ELECTRICAL DRAWINGS FOR LOCATIONS OF UTILITY AND GENERAL PURPOSE RECEPTACLES. REQUIREMENTS TO MECHANICAL EQUIPMENT J� �FCTR��J' ��* Q L z <br /> G. EC TO VERIFY THE UTILITY REQUIREMENTS FOR ITEMS NOT PROVIDED BY THE KITCHEN EQUIPMENT SUPPLIER. 10 RUN CONTROL WIRES VIA MASTER RELAY CONTROL gTFOF CA��F�� � W Q Q <br /> H. ALL PORTIONS OF WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND NATIONAL CODES, ORDINANCES AND PANEL. SEE SHEET E-5. CO 0 <br /> STANDARDS. 4k , 0 i z <br /> I. NOTIFY THE KITCHEN EQUIPMENT SUPPLIER PROJECT MANAGER IMMEDIATELY OF COMPLIANCE WITH A LOCAL, STATE OR NATIONAL CODE IS IN E�E��ICAL ROOF POWER PLAN 11 120V/ 10 WATER PROOF, GFCI RECEPTACLE BY RENEWAL DATE 9-30-20 o A/ w p [� <br /> CONFLICT WITH THESE DRAWINGS. ELECTRICAL CONTRACTOR. 5710 GARFIELD AVE. SUITE C iii � L=L p 0 � <br /> Ld <br /> SC -O° SACRAMENTO, CA. 95841 p p p O <br /> (916) 344-4878 � o 0 N N 0_ <br /> ELECTRICAL CONTRACTOR (EC) - WALK-IN COOLER/FREEZER: JOB NUMBER: 2193562 <br /> A. EC TO PROVIDE AND INSTALL A HEATING ELEMENT ON THE COOLER AND FREEZER CONDENSATE DRAIN LINES. DRAWN BY: DMC/SDB <br /> B. EC TO CONNECT THE PRIMARY ELECTRICAL SERVICE TO THE CONDENSING UNITS AND INTER-WIRE TO THE EVAPORATOR COIL(S), CONTROLS, CHECKED BY: DMC E - 2 <br /> LIGHTING FIXTURES AND DOOR PERIMETER HEATERS. <br />