My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
2994
>
1600 - Food Program
>
PR0547204
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 12:14:02 PM
Creation date
10/7/2021 3:50:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547204
PE
1625
FACILITY_ID
FA0026788
FACILITY_NAME
BURGER KING #27834
STREET_NUMBER
2994
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
2994 W EIGHT MILE RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANEL SCHEDULES ELECTRICAL PANEL SCHEDULE LOAD CALCULATIONPOWER SOURCE MANUAL RESET RELAY <br /> PANEL: A VOLTAGE: 120/208 3 PHASE 4 WIRE BUS: 225 AMPERES (FED AT 200A) <br /> TYPE: TITLE 24 PANELBOARD FAULT CURRENT RATING: 17 K.A.I.C. MIN. MOUNT: FLUSH PANEL: D SERVICE: 120/208/24OV, 3P, 4W + GNDFEEDERS: SEE ONE LINE DIAGRAM PANEL A = 54.1 KVA MCP ELECTRIC GAS VALVE Q <br /> LOAD KVA C.B. No. S / N No. C.B. KVA LOAD FAULT CURRENT RATING: 14 K.A.I.C. MIN. BUS RATING: 150A M.L.O. MOUNTING: FURNISHED BY EQUIPMENT SUPPLIER PANLE B = 62. KVA <br /> SPACE FOR FUTURE CT'S AND PANEL D = 44.11 KVA <br /> METERING EQUIPMENT LOAD DESCRIPTION NOTE LOAD WIREB/P A B C CB/P WIRE LOAD NOTE LOAD DESCRIPTION TOTAL = 160.9 KVA MICROSWITCH <br /> LIGHTING LOADS LIGHTING LOADS VOLT-AMP VOLT-AMP <br /> LTS-AREA 0.3 20 1 L1 L2 20/1 0.2 LTS-DINING ROOM PHU/MICROWAVE 1920 12 20/2 1 2 20/2 12 1920 PHU/MICROWAVE 160.9 KVA 208V, 30, 4W = 446.9 AMPS JUNCTION BOXES o <br /> LTS-BUILDING EXTERIOR 1.6 L3 L4 0.5 LTS-DINING ROOM 1920 12 3 4 12 1920 PROVIDE 600A, 120/208V, 30, 4W SERVICE Ln <br /> LTS-BUILDING EXTERIOR 1.5 L5 L6 0.7 LTS-KITCHEN PHU MICROWAVE 1920 12 20 2 5 ^ 6 20 2 12 1920 PHU/MICROWAVE RESET POWER w <br /> / / / EXTERNAL WIRING � <br /> SPACE L7 L8 0.3 LTS-KITCHEN TOILETS SERVICE BUTTON INDICATOR <br /> 1920 12 7 ^ 8 12 1920 GND r - - - - - - - - - <br /> SPACE L9 L10 0.4 LTS-RESTROOM EF-2 m <br /> CONVEYOR TOASTER 1920 12 20/2 9 10 20/2 12 1920 EGG COOKER o <br /> DRIVE-THRU MENU SIGNS 0.7 L11 L12 0.1 LTS-SERVICE OFFICE RED I LOAD GND w <br /> CHANNEL LETTERS LOGO 1.2 L13 L14 SPARE 1920 12 11 ^ 12 12 1920 A B SCREV6 Y <br /> RED LED LIGHTS 0.2 L15 L16 VERTICAL TOASTER 2880 10 30/2 13 ^ 14 20/1 12 1920 SPARE (N UE RA ND <br /> CHANNEL LETTERS LOGO 1.2 L17 L18 2880 10 -c-l'-16 20/1 12 1920 SANDWICH STATION <br /> CHANNEL LETTERS LOGO 1.2 L19 L20 PFB SPACE HEATED SURFACES 240 12 20/1 17 ^ ^ 18 30/2 10 2880 VERTICAL TOASTER RELAY 4 N.O. CONTACT <br /> DIRECTIONAL SIGNS 0.7 L21 L22 SPACE 19 ^ ^ 20 2880 COIL <br /> SPACE PFB L23 L24 4- UTILITY 1920 12 20/1 21 ^ 22 20/1 12 1920 UTILITY 6 3 1 FIRE EXT. MICROSWITCH <br /> SPACE FOR FUTURE CTS SPACE 23 ^ 24 SPACE 9 COMMON CONTACTS <br /> MECHANICAL LOADS MECHANICAL LOADS 3 m <br /> 60 M1 M2 50 TOTAL CONNECTED LOAD: 40560 VA PHASE 'A': 15360 VA NOTES (TC) = WIRE THROUGH CONTACTOR. 2 N.C. CONTACT m w <br /> 4 120V 60 HZ z <br /> RTU-1 9.4 M3 M4 9.4 RTU-2 TOTAL CONNECTED AMPS: 112 AMP PHASE 'B': 16320 VA (HACR) = HACR TYPE BREAKER. < Q <br /> 3 M5 M6 3 (LO) = LOCKED BREAKER 7 1 LOAD o <br /> 50 M7 M8 7/13, <br /> PHASE 'C': 10800 VA (GFCI) = GROUND FAULT CIRCUIT INTERRUPTOR <br /> 1 10A MAX. RESISTIVE o <br /> RTU-3 9.4 M9 M109.4 RTU-4 (IG) = WIRE SEPARATE TO ISOLATED GROUND BUS. RESET RELAY 10A MAX. Z <br /> 3 M11 M12 NOTE: ALL RECEPTACLES TO PANEL 'D' TO BE GFCI. EXTERNAL CONTACT CLOSURE REQUIRED <br /> EF-1 #23A 0.7 20 M13 M14 20 0.7 EF-2 33A MANUAL RESET RELAY WIRING SCHEMATIC <br /> M15- M16 <br /> SPACE PFB 2 M17 M18 PFB 2 SPACE AMEREX AUTOMATICo <br /> M19 M20 FIRE CONTROL SYSTEM <br /> M21 M22 <br /> M23 M24 SCALE: NONE01 <br /> 0 <br /> SPACE FOR FUTURE CT'S <br /> o c� <br /> WATER SYSTEM LOADS WATER SYSTEM LOADS <br /> WATER HEATER 0.2 20/1 W1 W2 PFB SPACE SINGLE 3/4" CONDUIT cv <br /> WATER BOOSTER #10A 1.4 20/1 W3 W4 z <br /> SPACE PFB W5 W6 ,n <br /> KVA: Ak A AL N <br /> 10.8x 125% = 13.5 + 39.0 + 1.6 = 54.1 KVA > Ln <br /> CIRCUIT A-26 v Q Ln <br /> 57.7 KVA/208V, 30, 4W = 160.3 AMPS MODEMP�jw <br /> � I <br /> 3/4" E.C. 0 ro <br /> O Q Lo <br /> 12"X12"X4" RECESSED MT'D. w W U I <br /> 1 1 TEL. CAB. LOCATE AS :� - O <br /> PROVIDE LABELS PER CEC 110.16 PROVIDE WITH EQUIPMENT AND ISOLATED GROUND BUSES MGROPT. . OFF. DIRECTED BY B.K. FIELD CD Q � 0 <br /> 6 <br /> GAME SERV. 1=PH; 2=FAX O o REP. COORD. WITH TEL. z � 0 <br /> LINES CNTR. DRIVE COMPANY Q � w <br /> PANEL: B VOLTAGE: 120/208 3 PHASE 4 WIRE BUS: 225 AMPERES (FED AT 200A) (PLAYGRND) THRU FLOOR a LL1 <br /> N E- NO SCALE _ <br /> TYPE: TITLE 24 PANELBOARD FAULT CURRENT RATING: 17 K.A.I.C. MIN. MOUNT: FLUSH 0 LINE DIAGRAM PROVIDE DUPLEX OUTLET IZ <br /> LOAD KVA C.B. I No. S/ N No. C.B. KVA I LOAD ADJACENT TO TEL. CABINET <br /> SPACE FOR FUTURE CTS AND ONE-LINE NOTES: TELEPHONE NOTE: 2" E.C. RUN OUT AND <br /> METERING EQUIPMENT 1. FAULT RATING: MINIMUM 25 K.A.I.C. TERMINATE AS DIRECTED BY <br /> RECEPTACLE AND APPLIANCE LOADS RECEPTACLE AND APPLIANCE LOADS 2. LABELS: PROVIDE LABELS AS REQUIRED BY C.E.C. ART. PROVIDE NYLON PULLCORD TEL. CO. (VERIFY SIZE) <br /> SERVICE CENTER/D.T. RECEIPT. 0.6 20 1 1 2 20 1 0.7 REAR DR BUZZER 110. IN EACH CONDUIT. <br /> RECP-P.O.S. 1.3 3 4 0.7 DOOR ALARM 3. SOLAR READY: OLELEPHONE RISER DIAGRAM <br /> RECP-P.O.S. 1.3 5 6 0.2 RECP-TELEPHONE 3.A. THERE IS SUFFICIENT CAPACITY FOR A 120A/3P <br /> SMOKE DETECTORS ALARM PNL 0.4 7 8 0.7 RECP-DINING PHOTOVOLTAIC SYSTEM. scALE. NONE <br /> RELAY PANEL 0.7 9 10 0.4 RECP-KITCHEN 3.6. LOCATE SPACE FOR FUTURE IN-FEED CIRCUIT Q <br /> ro <br /> OCU CREDIT CARD SWIPE 0.7 11 12 1.2 RECP-OFFICE BREAKER FOR PHOTOVOLTAIC SYSTEM OPPOSITE ON v Lo <br /> RECP-CREW STORAGE 0.5 13 14 0.3 RECP-SAFE #70 M THE BUS FROM THE MAIN CIRCUIT BREAKER. <br /> D T SPEED SERV #90C CAM 0.5 15 16 1 1 1.2 RECP-OFFICE / 45 <br /> SERVICE COUNTER/CORR. 0.4 17 18 SPARE 600A 3P i. <br /> RECP-ROOF EXTERIOR 0.7 19 20 MAIN CB <br /> SPACE PFB 21 22 V X <br /> 23 24 0 o <br /> 25 26 NEMA 3R 4W <br /> 3� <br /> 208V, , , _ <br /> 27 28 0.4 COOL FRZR LTS DR HEATER 600A BUS 120/208V, �--I °� o <br /> DIGITAL MENU BOARD 94A 0.9 20 1 29 30 1.3 FRYER CONTROLS 31 C/1 �r- <br /> VITAMIX BLENDER 059C 1.9 31 32 1.0 RECH-IN FREEZER 40A ) 20OA/3P ) 200A/3P ) 150A/3P ) PFB 3P 'T <br /> Lo <br /> REFRIG. BEV STATION 12 0.4 33 34 1.2 MEAT FREEZER 25 / =�j ti w <br /> JUICER #20 1.2 35 36 0.4 BROILER <br /> SELF-SERV DRINK DI SP 10 0.6 37 38 0.4 PRODUCT HOLD FREEZER 32 G N PROVIDE PROVISIONS FOR <br /> o FUTURE SOLAR ENERGY �J <br /> DRIVE-THRU DRINK DISP 11 0.6 39 40 ��2 <br /> 3.3 PRODUCT HOLDING UNIT 31 z z w <br /> o Z CONNECTIONS) <br /> SHORTENING STOR. UNIT 31 B 0.5 41 42 m N o <br /> FRY HOLD STATION 30 2.4 30 1 43 44 30 o w m m o <br /> COFFEE TEA BREWER 17 3.6 7�'2 <br /> 45 46 9.6 BISCUIT OVEN #36 Nm __jw o <br /> 47 48 13Luz w o Of � z <br /> 49 50 SPACE FOR FUTURE CT'S w z o m oLij 0 <br /> 51 52 c' m � Z o CD <br /> REFRIGERATED LOADS 53 54 REFRIGERATED LOADS o w o N N J v <br /> w w <br /> 30 55 56 ��2 <br /> 2.8 SOFT SERVE MACHINE N 0 cn vi � z w <br /> WALK-IN FREEZER CONDENSOR 9.1 57 58 15 w 0 o J J <br /> 3 59 60 30 3.4 FROZEN COKE MACHINE ``' <br /> WALK-IN COOLER CONDENSOR 0.9 20 61 62 2 14 0- w o Q z o _ R <br /> 2 63 64 20 Lij <br /> SPACE PFB 65 66 4.3 ICE MACHINE a_ m m v o v o v �Qti w>. o °' � <br /> 67 68 3 cv ~ ~ F__ C5 r ) rn ; w= "t 0 ? 6 <br /> 0 0 0 0 -14 <br /> 69 70 PFB SPACE I <br /> 0 o N N w F ° <br /> 71 72 PFB SPACE C" o o 04 o t, <br /> N ¢ N ¢ NQ �O^ Lazo x <br /> KVA: P� y <br /> 62.7 KVA <br /> 62.7 KVA/208V, 30, 4W = 174.2 AMPS PNL A PNL B PNL D <br /> O <br /> PROVIDE LABELS PER CEC 110.16 PROVIDE WITH EQUIPMENT GROUND BUS <br /> w � <br /> c' Z <br /> CHASE - Q <br /> ELECTRICAL o (n <br /> ENGINEERING N Ld <br /> w Q cf) <br /> oQ�OF ESS/pN9l N W <br /> M L Q <br /> w cn <br /> w w <br /> E-953 Ld Z z <br /> Q <br /> 00 � <br /> J�9TFFC TR�rJ O���P ' o) <br /> OF CA��F o W v <br /> N - <br /> RENEWAL DATE 9-30-20 4 N O <br /> o <br /> 5710 GARFIELD AVE. SUITE C � LLi 0 o y W <br /> SACRAMENTO, CA. 95841 <br /> (916) 344-4878 � o 0 N W <br /> JOB NUMBER: 2193562 <br /> DRAWN BY: DMC/SDB E e <br /> CHECKED BY: DMC <br />
The URL can be used to link to this page
Your browser does not support the video tag.