My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
700
>
2800 - Aboveground Petroleum Storage Program
>
PR0527961
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2022 10:58:13 AM
Creation date
10/12/2021 10:50:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0527961
PE
2832
FACILITY_ID
FA0018952
FACILITY_NAME
AAFES WEST COAST DISTRIB CENTER
STREET_NUMBER
700
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95231-9735
APN
19802001
CURRENT_STATUS
01
SITE_LOCATION
700 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J D AR I N Environmental Health Department <br /> I Y AMENDED <br /> 10/19/2021 <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AAFES WEST COAST DISTRIB CENTER 700 E ROTH RD, LATHROP October 05, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 716 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> OBSERVATION: Testing of liquid level sensing devices is not discussed in the SPCC plan for all APSA regulated <br /> containers. <br /> REGULATION GUIDANCE: 112.8(c)(8)(v)You must regularly test liquid level sensing devices to ensure proper <br /> operation. <br /> CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br /> regularly tested to ensure proper operation. Immediately conduct all necessary testing of the 350-gallon diesel <br /> emergency generator and 500-gallon diesel fuel tank liquid level sensing devices to ensure proper operation, submit <br /> test results to the EHD. <br /> This is a repeat violation, Class II. <br /> 718 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br /> OBSERVATION: The facility failed to promptly correct visible discharges of from the 350-gallon diesel emergency <br /> generator. Leakage was observed on the floor of the emergency generator during the inspection. The emergency <br /> generator has a current log of when the emergency generator is inspected but the leakage was not addressed. <br /> In addition,the SPCC Plan does not discuss promptly correcting visual discharges. <br /> REGULATION GUIDANCE: 112.8(c)(10)Promptly correct visible discharges which result in a loss of oil from the <br /> container, including but not limited to seams, gaskets, piping, pumps, valves, rivets, and bolts.You must promptly <br /> remove any accumulations of oil in diked areas. <br /> CORRECTIVE ACTION: Ensure the SPCC Plan addresses promptly correcting visual discharges and immediately <br /> address the leakage at the emergency generator, and manage all wastes according to the California Code of <br /> Regulations Title 22 hazardous waste regulations, submit proof of correction to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0018952 PR0527961 SCO01 10/05/2021 <br /> EHD 28-01 Rev.9/16/2020 Page 8 of 10 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.