0 <br />J <br />w <br />z <br />Y <br />z <br />w <br />c� <br />g <br />z <br />O <br />0 <br />w <br />Q <br />m <br />z <br />O <br />z <br />w <br />0 <br />m <br />Y <br />z <br />9 <br />J <br />Q <br />w <br />O <br />1'-0" CHAMFER <br />(TYP.) O <br />OVERALL TANK SLAB VARIES WITH <br />NUMBER AND DIAMETER OF TANKS <br />2' <br />TYP. <br />SAWED CONTROL JOINTS <br />TYPICAL TANK SLAB REINFORCING <br />NOT TO SCALE <br />TURBINE AND ATG <br />SUMP (TYP.) <br />CONTROL JOINTS TO <br />BE "TOOLED" WITH <br />3/8" RADIUS <br />42" DIA. FILL & <br />VAPOR VAPOR <br />RECOVERY SUMP <br />WITH STAGE II & <br />VENT (TYP.) <br />NOTES: <br />OPENINGS IN SLAB TO HAVE 1-1/2" <br />CROWN <br />TANK PAD SHALL EXTEND A MINIMUM <br />2'-0" BEYOND OUTSIDE WALLS OF <br />TANKS, AND MUST COVER THE ENTIRE <br />FOOTPRINT OF THE TANKS. IN ORDER <br />TO PROVIDE FOR PROPER TANK HOLD <br />DOWN, AND TO PREVENT ACCIDENTAL <br />DRILLING INTO TANK. <br />CHAMFER SLAB CORNERS WHERE <br />MEETING ASPHALT PAVING ONLY. <br />SQUARE CORNERS WHERE MEETING <br />CONCRETE. <br />8" MIN. FIBER REINFORCED <br />CONCRETE SLAB. SEE <br />SPECIFICATIONS AT RIGHT. <br />CONCRETE SLAB DESIGN <br />4,000 P.S.I. @ 28 DAYS <br />CONCRETE SIDE AND EDGES OF ISLAND TO <br />ISLAND HAVE SMOOTH TOWELED FINISH. <br />DESIGN WITH TOP TO HAVE MEDIUM BROOM <br />4,000 P.S.I. FINISH <br />FORMLESS CONCRETE ISLAND PLAN VIEW <br />SCALE: 1"=l'—O" <br />1 " TOOLED RADIUS (TYP.) <br />OPENING FOR CAST IN UDC <br />CENTERED IN ISLAND <br />v d <br />• v <br />v d a <br />d d Q d. v <br />d' G. d 4 <br />d• d <br />J d <br />v <br />a <br />4 dQ d <br />5'-0" <br />FORMLESS CONCRETE ISLAND 5'-0' SECTION <br />SCALE: 1"=l'—O" <br />44 <br />1 " TOOLED RADII <br />MINIMUM HEIGHT NC <br />6" UNLESS APPROV <br />Concrete Slab Specifications <br />NOTE: <br />CALIFORNIA VARIANT: <br />CONCRETE SHALL BE NORMAL WEIGHT WITH A MIX OF 1 : 2 1/2 : 3 1/2, WITH A MAXIMUM 7 <br />1. <br />CONCRETE SLAB OVER TANKS WITH A MINIMUM 8" THICK FIBER REINFORCEMENT TO BE USED. REINFORCE CONCRETE SLAB AROUND <br />1 GALLONS OF WATER PER SACK. ADD 3.0 LB MARCO (STRUCTURAL) FIBER PER CU. YD. <br />�� <br />MANHOLES WITH (4) #4 REBAR, 60" IN LENGTH FOR THE LARGE MANHOLES AND 30" FOR SMALL MANHOLES PLACE REBAR 6" FROM <br />REINFORCING CONCRETE. <br />d . v <br />. d <br />SIDES OF BOX. SEE RECIPE BELOW. <br />d v d <br />2. <br />THICKEN CONCRETE SLAB AT DISPENSER SUMPS AND TANK FILL AND TURBINE SUMPS SUCH THAT THE BOTTOM OF CONCRETE IS BELOW <br />OIN <br />LENGTH FOR LARGE MANHOLES 30" FOR SMALL MANHOLES. PLACE <br />THE TOP OF THE TERMINATION OF THE SECONDARY CONTAINMENT OF THE SUMPS PER AB -2481 REQUIREMENTS. <br />REINFORCING STEEL FOR TANK SUMP CAGES SHALL BE #4 REBAR. <br />3. <br />CONCRETE DRIVE SLAB AT CANOPY FUELING AREA WITH A MINIMUM 6" THICK FIBER REINFORCED CONCRETE TO BE USED. SEE RECIPE <br />MAINTAIN CONCRETE IN A MOIST CONDITION FOR AT LEAST 7 DAYS AFTER PLACEMENT. <br />d <br />BELOW. <br />va 4 <br />4. <br />CONCRETE FORMLESS ISLAND WITH A 6" HEIGHT ABOVE FINISHED GRADE FIBER REINFORCED CONCRETE TO BE USED. <br />PLACE CONCRETE DIRECTLY FROM TRUCK INTO FORMS. DO NOT PUMP CONCRETE UNLESS SPECIAL <br />PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br />SEE RECIPE BELOW. <br />INSPECTION, IN ACCORDANCE WITH CHAPTER 3 OF THE IBC, IS PROVIDED. <br />6 <br />PROPER TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING <br />SUBMIT MIX DESIGNS, WITH STRENGTH AND SHRINKAGE TEST RESULTS, TO OWNER'S ENGINEER AT <br />CONCRETE MIX RECIPE. PREMIX UNIFORMLY THROUGHOUT CONCRETE. REINFORCEMENT BARS TO BE NO LESS THAN 2" <br />LEAST 7 DAYS BEFORE PLACING CONCRETE. <br />AND NO MORE THAN 4" FROM SURFACE. <br />CONSOLIDATE CONCRETE IN PLACE USING A MECHANICAL VIBRATOR. <br />UNLESS <br />OTHERWISE NOTED ON THESE DRAWINGS: <br />v d• <br />a. <br />CONCRETE - REGULAR WEIGHT HARD ROCK CONCRETE (150 LBS/CU FT) <br />BEFORE PLACING CONCRETE, SECURE REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND OTHER <br />BY THE LOCAL DISTRIBUTION TERMINAL MANAGER OR HIS AGENT. FINAL <br />CEMENT - TYPE I/II, SULFATE RESISTANT <br />INSERTS IN POSITION TO PREVENT MOVEMENT. <br />c. <br />c. <br />AGGREGATES - ASTM C33, (MAXIMUM SIZE 3/4 INCHES) <br />MATERIALS AND WORKMANSHIP SHALL CONFORM TO A.C.I. - 318 (SPECIFICATIONS OF THE DESIGN <br />d. <br />28 DAY CONCRETE STRENGTH (f'c): <br />AND PLACEMENT OF CONCRETE). <br />c d . <br />4,000 PSI - SLAB (DESIGN BASED ON 2,000 PSI NO SPECIAL INSPECTION REQUIRED) <br />MANHOLE CROWNS: <br />e. <br />SLUMP - 3"+ 1" - 4" MAXIMUM AT POINT OF PLACEMENT <br />ALL MANHOLE OPENINGS ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2" CROWN (1" RISE <br />f. <br />SHRINKAGE - 0.05% MAXIMUM <br />OVER 12" RUN) OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. THE OWNER'S <br />9. <br />ENTRAINED AIR RANGE - 2% TO 4% <br />ENGINEER, THE BP PROJECT MANAGER WILL BE REQUIRED TO SIGN OFF ON THIS ITEM ON THE <br />SIDE „A» <br />c <br />TANK INSTALLATION CHECKLIST. <br />Q L u <br />U)Z� W <br />m <br />PRODUCT IDENTIFICATION MARKINGS: <br />O z o <br />CONTRACTOR TO INSTALL PRODUCT IDENTIFICATION TAGS AT ALL MANHOLE OPENING PER SITE <br />Z z <br />z <br />0 z N <br />SPECIFIC DETAIL DRAWINGS. <br />FORMLESS CONCRETE ISLAND PLAN VIEW <br />SCALE: 1"=l'—O" <br />1 " TOOLED RADIUS (TYP.) <br />OPENING FOR CAST IN UDC <br />CENTERED IN ISLAND <br />v d <br />• v <br />v d a <br />d d Q d. v <br />d' G. d 4 <br />d• d <br />J d <br />v <br />a <br />4 dQ d <br />5'-0" <br />FORMLESS CONCRETE ISLAND 5'-0' SECTION <br />SCALE: 1"=l'—O" <br />44 <br />1 " TOOLED RADII <br />MINIMUM HEIGHT NC <br />6" UNLESS APPROV <br />NOTES: UST INSTALLATION <br />NOTE: <br />d <br />. <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br />Cl) <br />REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br />�� <br />CONCRETE. <br />vaSIDE »B» o <br />d . v <br />. d <br />OREINFORCING <br />d v d <br />•A <br />d d <br />v I+ v <br />OIN <br />LENGTH FOR LARGE MANHOLES 30" FOR SMALL MANHOLES. PLACE <br />d Q.:d <br />I <br />DEPENDENT UPON EXISTING SITE CONDITIONS. CONTRACTOR WILL <br />USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN <br />O)s" <br />d <br />REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF THIS DESIGN <br />va 4 <br />v' <br />OTANK <br />PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br />0 <br />COVER THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR <br />6 <br />PROPER TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING <br />INTO TANK. <br />Ld <br />CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE <br />OPENING FOR UDC <br />d. <br />:. <br />v d• <br />< <br />vII <br />OF SUMP � <br />BY THE LOCAL DISTRIBUTION TERMINAL MANAGER OR HIS AGENT. FINAL <br />FESS /0 <br />LOCATION SIGN—OFF SHALL BE DOCUMENTED. <br />Ci <br />� <br />* XP. 6-30-22 <br />d' <br />w <br />Id d <br />c d . <br />Lu <br />wco <br />�• <br />d-4-. <br />d d 4-,, <br />d Q'd <br />o <br />Z <br />w N <br />LD u) °2 o <br />d <br />SIDE „A» <br />c <br />Q L u <br />U)Z� W <br />m <br />I I w w <br />Lu <br />O z o <br />`-'zom <br />U U 0 <br />Z z <br />z <br />0 z N <br />mUJ <br />5'-0" <br />C7 0 0 <br />06 <br />FORMLESS CONCRETE ISLAND PLAN VIEW <br />SCALE: 1"=l'—O" <br />1 " TOOLED RADIUS (TYP.) <br />OPENING FOR CAST IN UDC <br />CENTERED IN ISLAND <br />v d <br />• v <br />v d a <br />d d Q d. v <br />d' G. d 4 <br />d• d <br />J d <br />v <br />a <br />4 dQ d <br />5'-0" <br />FORMLESS CONCRETE ISLAND 5'-0' SECTION <br />SCALE: 1"=l'—O" <br />44 <br />1 " TOOLED RADII <br />MINIMUM HEIGHT NC <br />6" UNLESS APPROV <br />ALL MANHOLE ACCESS COVERS — <br />TO BELOW GRADE SHALL BE <br />LIQUID TIGHT AND LOCKABLE <br />(TYP.) <br />A . PAVING —1-1/2 1 18" <br />THICKENED (TYP. ALL) (TYP.) <br />CONCRETE EDGE <br />=.. <br />_ . ' <br />a° a <br />-4A <br />° • :e <br />r Ae <br />. d <br />A SLAB SECTION AT TANKS <br />SCALE: 1/2" = 1'-0" <br />ELECTRICAL CONDUIT <br />POUR CONCRETE WITHIN THE <br />ELECTRICAL OFFSET OPENING <br />STEEL FRAME BETWEEN <br />DISPENSER SUMP, SEAL WHERE <br />CONCRETE OR CONDUIT MEET <br />STEEL. SEAL THE DOWNSIDE OF <br />THE SLOPE AND THE CONDUIT <br />AREA WITH "VULKEM 116" <br />SLOPE CONCRETE <br />UDC FRAME <br />TANK SLAB SHALL BE THICKENED <br />AT TANK SUMP EXTEND TO WHERE <br />TO MONITORING END AT THE SUMP <br />01 18 1-1/2" <br />(TYP.(TYP. ALL) <br />Ad A <br />• .. w D' <br />V d CY Ld <br />L 3" PEA -GRAVEL <br />MIN. TO PREVENT <br />LOAD TRANSFER <br />TO TANK TOP <br />O <br />® <br />NOTES: UST INSTALLATION <br />NOTE: <br />d <br />. <br />ALL MANHOLE ACCESS COVERS — <br />TO BELOW GRADE SHALL BE <br />LIQUID TIGHT AND LOCKABLE <br />(TYP.) <br />A . PAVING —1-1/2 1 18" <br />THICKENED (TYP. ALL) (TYP.) <br />CONCRETE EDGE <br />=.. <br />_ . ' <br />a° a <br />-4A <br />° • :e <br />r Ae <br />. d <br />A SLAB SECTION AT TANKS <br />SCALE: 1/2" = 1'-0" <br />ELECTRICAL CONDUIT <br />POUR CONCRETE WITHIN THE <br />ELECTRICAL OFFSET OPENING <br />STEEL FRAME BETWEEN <br />DISPENSER SUMP, SEAL WHERE <br />CONCRETE OR CONDUIT MEET <br />STEEL. SEAL THE DOWNSIDE OF <br />THE SLOPE AND THE CONDUIT <br />AREA WITH "VULKEM 116" <br />SLOPE CONCRETE <br />UDC FRAME <br />TANK SLAB SHALL BE THICKENED <br />AT TANK SUMP EXTEND TO WHERE <br />TO MONITORING END AT THE SUMP <br />01 18 1-1/2" <br />(TYP.(TYP. ALL) <br />Ad A <br />• .. w D' <br />V d CY Ld <br />L 3" PEA -GRAVEL <br />MIN. TO PREVENT <br />LOAD TRANSFER <br />TO TANK TOP <br />O <br />® <br />NOTES: UST INSTALLATION <br />NOTE: <br />O1 <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br />OFIBER <br />REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br />CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. <br />CONCRETE. <br />THE OWNER'S ENGINEER WILL BE REQUIRED TO SIGN OFF ON THIS <br />BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" <br />OREINFORCING <br />FROM SURFACE. <br />ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL <br />REINFORCE CONCRETE SLAB AROUND MANHOLES WITH (4) #4 REBAR 60" <br />OIN <br />LENGTH FOR LARGE MANHOLES 30" FOR SMALL MANHOLES. PLACE <br />PAID. CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE <br />REBAR 6" FROM SIDES OF BOX. <br />DEPENDENT UPON EXISTING SITE CONDITIONS. CONTRACTOR WILL <br />USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN <br />O)s" <br />& MAX OF 3/4" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. <br />REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF THIS DESIGN <br />ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S <br />FIELD REPRESENTATIVE. <br />OTANK <br />PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br />0 <br />COVER THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR <br />PROPER TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING <br />INTO TANK. <br />10 <br />CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE <br />OCUT <br />CORNERS WHERE MEETING CONCRETE. <br />SEE SITE SPECIFIC PLANS FOR ACTUAL TANK SIZES, PLACEMENT, AND <br />< <br />ORIENTATION. FINAL SITE SPECIFIC TANK LAYOUTS SHALL BE APPROVED <br />BY THE LOCAL DISTRIBUTION TERMINAL MANAGER OR HIS AGENT. FINAL <br />FESS /0 <br />LOCATION SIGN—OFF SHALL BE DOCUMENTED. <br />8" MIN. FIBER REINFORCED <br />CONCRETE SLAB. SEE <br />SPECIFICATIONS ABOVE. < <br />CONCRETE SLAB DESIGN <br />4,000 P.S.I. @ 28 DAYS <br />A.C. <br />PAVING <br />3" PEA -GRAVEL MIN. TO <br />PREVENT LOAD TRANSFER <br />TO TANK TOP 5O <br />#4 AROUND ALL <br />PENETRATIONS 3 4 <br />NOTE: <br />bp <br />NOTE: <br />ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2" <br />BP WEST COAST PRODUCTS, LLC <br />CONTRACTOR IS REQUIRED TO THICKEN CONCRETE SLAB AT TANK <br />FILL AND TURBINE <br />CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. <br />SUMPS SUCH THAT THE BOTTOM OF CONCRETE IS BELOW THE TOP OF THE TERMINATION <br />THE OWNER'S ENGINEER WILL BE REQUIRED TO SIGN OFF ON THIS <br />ITEM <br />OF THE SECONDARY CONTAINMENT OF THE SUMPS PER AB -2481 <br />REQUIREMENTS. NOTE <br />ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL <br />BE <br />THAT THE THICKNESS MAY VARY BETWEEN THE FILL AND TURBINE <br />SUMPS AND IS ALSO <br />PAID. CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE <br />SLAB <br />DEPENDENT UPON EXISTING SITE CONDITIONS. CONTRACTOR WILL <br />BE REQUIRED TO <br />AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT MET. <br />REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF THIS DESIGN <br />REQUIREMENT IS NOT <br />0 <br />MET AS DETERMINED BY THE GOVERNING JURISDICTION. <br />CAULK WITH "VULKEM 116" OR <br />OTHER SUITABLE HYDROCARBON <br />RESISTANT CAULK <br />DISPENSER <br />DISPENSER <br />BASE MOUNT <br />d <br />�.4 v <br />JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY —� <br />WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 v <br />PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" <br />OR EQUAL. 1/2" DEEP <br />d .. <br />a g <br />a <br />DISPENSER ISLAND <br />JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY <br />WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 <br />PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" <br />OR EQUAL. 1/2" DEEP <br />a <br />z d d <br />U) g <br />W W 4 <br />W <br />1/2" EXPANSION JOINT <br />1/4" RADIUS TOOL EDGE <br />INSTALL "SNAP CAP" OR <br />EQUAL, REMOVE AFTER <br />CONCRETE HAS CUREED AND <br />`No FILL JOINT WITH SEALANT <br />;q. <br />1/2" EXPANSION JOINT <br />MATERIAL SHALL COMPLY WITH <br />ASTM D1751. JOINT FILLER <br />4 CAST IN PLACE <br />a <br />d d <br />v <br />NEW FIBER REINFORCED—"' I ANEW FIBER REINFORCED <br />CONCRETE CONCRETE <br />1/2" EXPANSION JOINT PER SPECIFICATIONS PER SPECIFICATIONS <br />1/4" RADIUS TOOL EDGE <br />INSTALL "SNAP CAP" OR EXPANSION CONSTRUCTION JOINT AT NEW PAVEMENT (TYPICAL). <br />EQUAL, REMOVE AFTER NOT TO SCALE <br />CONCRETE HAS CUREED AND <br />FILL JOINT WITH SEALANT JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY 1/2" JOINT <br />° v d WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 <br />'.4 <br />1/2" EXPANSION JOINT PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" 1 /4" RADIUS TOOL EDGE <br />. .v MATERIAL SHALL COMPLY <br />WITH ASTM D1751. JOINT OR EQUAL. 1/2" NEW PAVEMENT EXISTING PAVEMENT DEEP <br />FILLER CAST IN PLACE INSTALL "SNAP CAP" OR <br />d <br />________ EQUAL, REMOVE AFTER <br />d CONCRETE HAS CUREED AND <br />N <br />v a .. d a. a <br />FILL JOINT WITH SEALANT <br />z <br />EXPANSION CONSTRUCTION JOINT AT DISPENSER ISLAND (TYPICAL). "MIN. FIBER w d v d 1/2" EXPANSION JOINT <br />REINFORCED CONCRETE L� a MATERIAL SHALL COMPLY WITH <br />NOT TO SCALE <br />FORMLESS CONCRETE USLAND 3'-0" SECTION <br />SCALE: 1"=l' -O" <br />DRIVE SLAB. SEE > w 4 4 ASTM D1751. JOINT FILLER <br />SPECIFICATIONS ABOVE. w v a CAST IN PLACE <br />d ' ° DRILL EXISTING CONCRETE <br />EXPANSION JOINT FOR DOWEL PLACEMENT <br />RADIUS TOOL EDGE 3/4" DIA. X 18" L. GREASED OR <br />COATED STEEL DOWEL @ 18" O.C. <br />-ALL "SNAP CAP" OR EQUAL, <br />OVE AFTER CONCRETE HAS <br />'EED AND FILL JOINT WITH <br />LANT <br />EXPANSION JOINT MATERIAL <br />ALL COMPLY WITH ASTM D1751. <br />JT FILLER CAST IN PLACE <br />6" MIN. FIBER REINFORCED <br />CONCRETE DRIVE SLAB. SEE <br />SPECIFICATIONS ABOVE. <br />NOT TO SCALE <br />JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY <br />WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 <br />PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" <br />OR EQUAL. 2" DEEP <br />CONTROL JOINT (SAWED) <br />NOT TO SCALE <br />W <br />I <br />I <br />SAWED JOINT 1/4" X 2" DEPTH <br />WITH FLARED EDGE EASER <br />ONOTE: INDICATES ITEMS FOUND ON <br />XX MATERIALS LIST SHEET M.5.3.01 & M.5.3.02 <br />CLIENT: <br />bp <br />ARCO <br />BP WEST COAST PRODUCTS, LLC <br />NO. <br />DATE <br />DESCRIPTION <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />10 <br />11 <br />0 <br />SEAL: <br />FESS /0 <br />NO. 36475 <br />* XP. 6-30-22 <br />C/o- <br />IVILO <br />- CAI -SFO <br />OF- <br />z <br />Lu <br />wco <br />co <br />Q mco <br />UQm <br />o <br />Z <br />w N <br />LD u) °2 o <br />mZ <br />COQ <br />Q <br />Q L u <br />U)Z� W <br />m <br />I I w w <br />Lu <br />O z o <br />`-'zom <br />U U 0 <br />Z z <br />z <br />0 z N <br />mUJ <br />wQ>_r <br />z Q <br />C7 0 0 <br />06 <br />z 't <br />UJ CC) w <br />Q <br />O O <br />z = <br />z 0- <br />z <br />g <br />DEVELOPMENT INFORMATION: <br />SITE ADDRESS: <br />ADDRESS <br />2510 S. STATE HWY 99 W. FRONTAGE ROAD <br />SAN JOAQUIN COUNTY, CA 95205 <br />DESIGNED BY: <br />CHECKED BY: <br />DRAWN BY: <br />ER <br />DATE: <br />PROJECT NO: <br />10/28/2019 <br />DRAWING TITLE: <br />TANK SLAB CONCRETE SPECIFICATIONS <br />AND IDENTIFICATION MARKING DETAILS <br />SHEET NO: <br />M,5,3,26 <br />