My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2022 10:43:11 AM
Creation date
11/10/2021 8:23:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />ESCALON MINI MART <br />1097 YOSEMITE AVE, ESCALON <br />December 21, 2021 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />208 <br />CCR 2716(a -e) Failure to comply with the designated operator inspection requirements. <br />OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br />reports. The incorrect and missing information included the following from the inspection reports: <br />- CERS ID <br />- Owner/operator printed name <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required <br />testing and maintenance for the UST system have been completed and shall check all required items on the report. <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br />all of the required information on the reports. <br />This is a repeat violation, Class II. <br />302 <br />CCR 2630(d), 2641(a) Leak detection equipment not installed/maintained/located to detect leaks at earliest <br />opportunity. <br />OBSERVATION: Per service technician, Mario Romero, the 91 sensor was raised approximately 1 inch off the <br />lowest point of the sump and not located to detect a leak at the earliest opportunity. <br />REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: Immediately relocate this sensor to the lowest point of the 91 sump. <br />This is a repeat violation, Class II. <br />306 <br />HSC 25291(e) Failure to remove, analyze, and properly dispose of water in secondary containment (pre -Jul 2003). <br />OBSERVATION: Liquid was observed in the 7/8 and 3/4 underground dispenser containment and 87 turbine sump. <br />REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br />must be removed and disposed of properly. <br />CORRECTIVE ACTION: Immediately remove this liquid, make a hazardous waste determination per Title 22 <br />hazardous waste regulations, and manage it accordingly. Ensure that all sumps and annular spaces are maintained <br />free of liquid. <br />This is a repeat violation, Class II. <br />FA0000279 PR0231497 SCO01 12/21/2021 <br />EHD 23-01 Rev. 12/06/2021 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.