P-2.0#KEYNOTESSCALE: 1/4" = 1'-0"1PLUMBING WASTE PIPING PLANNORTH SEE DRAWING P-1.2 FOR PLUMBING PIPE SIZING123456POINT OF CONNECTION TO EXISTING SANITARY SEWER PIPINGCONTRACTOR TO VERIFY EXACT SIZE, LOCATION AND SLOPEPOINT OF CONNECTION TO EXISTING GREASE WASTE PIPINGCONTRACTOR TO VERIFY EXACT SIZE, LOCATION AND SLOPEDASHED LINE INDICATES CONDENSATE DRAIN LINE FROM HVAC UNITSIZED AS INDICATED. PROVIDE CLEANOUTS, AS INDICATED - SEE DETAILSEE DRAWING P-1.1 FOR PIPE SIZING INFORMATIONSANITARY SEWER PIPING, SEE DRAWING P-1.1 FOR PIPE SIZING INFORMATIONSLOPE SANITARY SEWER PIPING ¼” PER FOOT IN DIRECTION INDICATEDREPAIR SLAB PER LANDLORD REQUIREMENTS - SEE DETAILGREASE WASTE PIPING, SEE DRAWING P-1.1 FOR PIPE SIZING INFORMATIONSLOPE SANITARY SEWER PIPING ¼” PER FOOT IN DIRECTION INDICATEDREPAIR SLAB PER LANDLORD REQUIREMENTS - SEE DETAILWATER PIPING - SEE DETAILPROVIDE 12" WATER LINE FOR TRAP PRIMERTYPICAL AT ALL FLOOR DRAINS AND FLOOR SINKSPLUMBING VENT THROUGH ROOF - SEE DETAILHATCHING INDICATES A REQUIRED INDIRECT WASTE CONNECTIONPROVIDED FLEXIBLE DRAIN PIPING FROM FIXTURE TO ADJACENT FLOOR SINKSEE DETAILTEMPERATURE AND PRESSURE RELIEF VALVE AND DRAIN LINEDRAIN TO BE A MINIMUM OF 2" ABOVE THE FLOOD RIM LEVEL OF MOP SINK OR TO THEEXTERIOR OF THE BUILDINGPOINT OF CONNECTION TO LANDLORD DOMESTIC WATER PIPINGSEE DRAWING P-2.0 FOR CONTINUATIONEXISTING WASTE AND VENT PIPING TO WATER CLOSET AND LAVATORY TO REMAINCONTRACTOR TO VERIFY EXISTING LOCATION, SLOPE, SIZE AND CONDITIONREPAIR, AS REQUIREDEXISTING WATER PIPING TO WATER CLOSET AND LAVATORY TO REMAINCONTRACTOR TO VERIFY EXISTING LOCATION,SIZE AND CONDITIONREPAIR, AS REQUIREDEXISTING TENANT WATER SHUT-OFF TO REMAINCONTRACTOR TO VERIFY LOCATIONPOINT OF CONNECTION TO EXISTING GAS LINESEE DRAWING P-1.1 FOR SIZE AND CONTINUATIONEXISTING SANITARY SEWER WASTE LINECONTRACTOR TO VERIFY EXISTING SLOPE, SIZE AND LOCATIONEXISTING GREASE WASTE LINE TO EXISTING 1,500 GALLON GREASE INTERCEPTORCONTRACTOR TO VERIFY EXISTING SLOPE, SIZE AND LOCATIONP-3.01178P-3.02&3P-3.049 SEE DRAWING P-1.1 FOR PLUMBING SCHEDULE AND SPECIFICATIONS#P-3.0810OFSHEETSTAF9/15/202020-162DRAWNAS SHOWNSCALEDATECHECKEDJOB NO.SHEETREVISIONSBYSLWPROJECT : <br />CLIENT : <br />LOCATION : <br />CRUMBL COOKIES <br />2624 W. KETTLEMAN LANE, #150 <br />LODI, CA 95242 <br />THEODORE J. BRANDVOLD, ARCHITECT <br />616 14th STREET, MODESTO, CA 95354 <br />PH (209) 571-8158 FAX (209) 571-8160 <br />JUST DOUGH IT RENEWAL DATEC-25449JATEO <br />DEONCE <br />SERLI <br />D <br />THEST <br />OFORNVTARCHITEC.BRANDLI ODACALIF6-30-21INTERIOR TENANT IMPROVEMENT <br />A.P.N.: 058-03-022SCALE: 1/4" = 1'-0"2PLUMBING WATER & GAS PIPING PLANNORTH1122574FDLAV-1PS1HS1CS1FS-1FS-1MS-1(E)WC-1(E)HS1GHWH(2)FDLAV-1PS1FCS1FFS-1FS-1MS-1F(E)WC-1(E)HS1(2)HS1AC-1AC-266688888899101112131112131414151516171617