E-1.0PART 1 - GENERAL1.1GENERAL NOTES1.SEE ARCHITECTURAL DRAWINGS FOR ALL APPLICABLE CODES2.ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING POWER AND PHONESERVICES AT SITE PRIOR TO BIDDING. SERVICES SHALL CONFORM TO UTILITY COMPANYREQUIREMENTS, ELECTRICAL CONTRACTOR SHALL ARRANGE FOR SERVICE INSTALLATION PER UTILITYCOMPANY REQUIREMENTS. ALL SERVICE INFORMATION AND LOCATIONS SHOWN ON THESE PLANS ARE ASSUMED, TO BE VERIFIED WITH THE RESPECTIVE UTILITY COMPANIES AND MODIFIED AS REQUIRED TO SUIT. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE UTILITIES COMPANIES IN A TIMELY FASHION TO OBTAIN AND COORDINATE THIS INFORMATION.3.ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, PERMITS, ETC. REQUIRED TOCARRY ON AND COMPLETE THE WORK.4.PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND PERFORMALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER EXECUTION AND COMPLETION OF ALL “ELECTRICAL WORK” WHETHER SPECIFICALLY MENTIONED OR NOT; ALL AS INDICATED, SPECIFIED HEREIN, AND/OR IMPLIED THEREBY TO CARRY OUT THE APPARENT INTENTTHEREOF.5.ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS’ LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BEAR THEIR LABEL WHEREVER STANDARDS HAVEBEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY.6.ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE ANDLOCATIONS OF EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE, CONTRACTOR SHALL MAKEUSE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES.7.CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.8.ALL LUMINARIES AND BALLASTS SHALL BE CERTIFIED BY THE MANUFACTURER TO THE CALIFORNIA ENERGY COMMISSION. ALL FLUORESCENT FIXTURES TO BE LAMPED WITH F032, T8, 4100K LAMPS OR APPROVED EQUAL, AND HAVE AN ENERGY SAVING “A” SOUND RATED ELECTRONIC BALLAST OR EQUAL,UNLESS OTHERWISE SHOWN. ALL H.I.D. LIGHT FIXTURES SHALL HAVE HIGH POWER FACTOR BALLASTS.9.FLASH AND COUNTERFLASH ALL ITEMS PASSING THROUGH THE ROOF. FLASHING SHALL BE COMPATIBLE WITH ROOFING SYSTEM.10.THE OWNER RESERVES THE RIGHT TO RELOCATE ALL LIGHTING, OUTLETS AND SWITCHES BEFORE THEY ARE ROUGHED IN AT NO EXTRA COST.11.RECEPTACLES IN RATED WALLS SHALL HAVE A MINIMUM OF 24” HORIZONTAL SEPARATION FROM THOSE IN ADJACENT ROOMS AT THE OTHER SIDE OF WALL.12.ALL GROUND WIRES SHALL BE INSULATED GROUNDS.13.THE ENTIRE LIGHTING INSTALLATION AND THE PRODUCTS USED SHALL BE IN COMPLIANCE WITH THE CALIFORNIA ENERGY EFFICIENCY STANDARDS.14.THE FOLLOWING SHALL BE PROVIDED PER PLANS AS A MINIMUM TO ENSURE COMPLIANCE:A.LIGHTING SHALL BE CONTROLLED BY SELF-CONTAINED LIGHTING CONTROL DEVICES WHICH ARE CERTIFIED TO THE ENERGY COMMISSION ACCORDING TO THE TITLE 24 EFFICIENCY REGULATIONS IN ACCORDANCE WITH SECTION 110.9.B.LIGHTING SHALL BE CONTROLLED BY A LIGHTING CONTROL SYSTEM OR ENERGY MANAGEMENTCONTROL SYSTEM IN ACCORDANCE WITH 110.9. AN INSTALLATION CERTIFICATE SHALL BE SUBMITTED IN ACCORDANCE WITH SECTION 130.4(B).C.ALL LIGHTING CONTROLS AND EQUIPMENTS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS IN 110.9 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS IN ACCORDANCE WITH SECTION 130.1.D.ALL LUMINARIES SHALL BE FUNCTIONALLY CONTROLLED WITH MANUALLY SWITCHED ON AND OFF LIGHTING CONTROLS IN ACCORDANCE WITH SECTION 130.1(A).E.THE GENERAL LIGHTING OF ANY ENCLOSED AREA 100 SQUARE FEET OR LARGER, WITH A CONNECTED LIGHTING LOAD THAT EXCEEDS 0.5 WATTS PER SQUARE FOOT SHALL MEETMULTI-LEVEL LIGHTING CONTROL REQUIREMENTS IN ACCORDANCE WITH SECTION 130.1 (B)F.ALL INSTALLED INDOOR LIGHTING SHALL BE EQUIPPED WITH CONTROLS THAT MEET THE APPLICABLE SHUTT-OFF CONTROL REQUIREMENTS IN SECTION 103.1(C)G.LIGHTING IN ALL DAY LIT ZONES SHALL BE CONTROLLED IN ACCORDANCE WITH THE REQUIREMENTS IN SECTION 130.1(D) AND DAYLIT ZONES ARE SHOWN ON THE PLANSH.BEFORE AN OCCUPANCY PERMIT IS GRANTED FOR A NEWLY CONSTRUCTED BUILDING OR AREA, OR A NEW LIGHTING SYSTEM SERVING A BUILDING, AREA OR SITE IS OPERATED FOR NORMAL USE, INDOOR LIGHTING CONTROLS SERVING THE BUILDING, AREA, OR SITE SHALL BECERTIFIED AS MEETING THE ACCEPTANCE REQUIREMENTS FOR CODE COMPLIANCE IN ACCORDANCE WITH SECTION 130.4(A), THE CONTROLS REQUIRED TO MEET THE ACCEPTANCEREQUIREMENTS INCLUDE AUTOMATIC DAYLIGHT CONTROLS, AUTOMATIC SHUT-OFF CONTROLS, AND DEMAND RESPONSIVE CONTROLS.15. THE FOLLOWING LIGHTING CONDITIONS NEED TO BE PROVIDED WITHIN THE FACILITY:A.DRY FOOD STORAGE AREA10 FOOT CANDLES AT 30" ABOVE FLOOR MINIMUM.B.SELF-SERVICE FOOD20 FOOT CANDLES MINIMUM.PRODUCE ORC.PREPACKAGED FOOD20 FOOT CANDLES MINIMUMD.INSIDE OF REACH-IN OR UNDER-COUNTER REFRIGERATION UNITS20 FOOT CANDLES MINIMUME.HAND WASHING, WARE WASHING, EQUIPMENT STORAGE, UTENSIL STORAGE AND RESTROOMS20 FOOT CANDLES AT 30" ABOVE THE FLOOR MINIMUM.F.FOOD EMPLOYEE WORK AREAS IN WHICH SAFETY IS A FACTOR (I.E.SLICING, CUTTING, GRINDING)50 FOOT CANDLES MINIMUM.16. ALL HEATING, AIR CONDITIONING AND REFRIGERATION EQUIPMENT SHALL HAVE A DISCONNECT WITHINSIGHT AND HAVE A SERVICE RECEPTACLE ON THE SAME LEVEL AND WITHIN 25 FEET OF THE UNIT.17. GFCI PROTECTION SHALL BE PROVIDED AT ALL KITCHEN AREA RECEPTACLES1.2 PENETRATIONSPENETRATIONS IN EXTERIOR WALLS SHALL BE SEALED AND RENDERED AS WATERTIGHT AS POSSIBLE1.3 WIRING METHODS1.ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS. CONDUITS SHALL BE RUN CONCEALED INWALLS AND CEILINGS.2.MINIMUM CONDUIT SIZE SHALL BE ½”. MINIMUM ACCEPTABLE CONDUITS AREA.GALVANIZED RIGID STEEL – FOR USE ON EXTERIOR WALL SURFACES AND ROOF. OBTAIN ARCHITECTS PERMISSION FOR SURFACE RUN.B.GALVANIZED STEEL EMT – FOR USE CONCEALED IN INDOOR SPACES.C.LIQUID TIGHT STEEL FLEX – FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. (NOT TO EXCEED 36”)D.FLEXIBLE STEEL CONDUIT – FOR INDOOR FINAL CONNECTIONS TO RECESSED LIGHT FIXTURES(NOT TO EXCEED 72”) AND HVAC EQUIPMENT.E.PVC CONDUIT APPROVED FOR USE UNDERGROUND ONLY.F.NO ALUMINUM CONDUITS, IMC CONDUITS OR ALUMINUM FITTINGS ARE APPROVED FOR USE ONTHIS PROJECT.G.ALL CONDUIT FITTINGS SHALL BE MALLEABLE IRON/STEEL.H.EMT COUPLINGAPPLETON TWC-CS SERIESEMT CONNECTORAPPLETON TW-CSI-SERIESFLEX CONDUIT CONNECTORT&B “TITE BITE”, INSULATED LIQUID TIGHT FLEX CONDUIT CONNECTORAPPLETON “STB” SERIES UP TO 2”, “ST” SERIES OVER 2”.J.RIGID STEEL CONDUIT CONNECTED TO BOXES AND CABINETS SHALL BE FITTED WITH TWO LOCKNUTS AND INSULATING BUSHING, OA “A” SERIES. PROVIDE GROUNDING BUSHING OZ “BL”SERIES WHERE LOCKNUTS AND BUSHING IS NOT USED. CONDUITS CONNECTED TO BOXES EXPOSED TO WEATHER/MOISTURE SHALL BE FITTED WITH WATERTIGHT SEALING HUBS OF STEEL OR MALLEABLE IRON WITH SEALING RING AND INSULATED THREAT, T & B 370 SERIES.K.NO MC OR AC CABLE TO BE USED ON THIS PROJECT.L.TYPE NM AND NMC CABLES SHALL NOT BE USED ON THIS PROJECT.PART 3 - EXECUTION3.1SUBMITTALS1.PROVIDE THE FOLLOWING SUBMITTALS FOR REVIEW AND APPROVAL.A.PANEL BOARDSB.LIGHT FIXTURESC.SERVICE SWITCHBOARD3.2WORKING CLEARANCES FOR PANELS & SWITCHBOARDSCOORDINATE WITH OTHER TRADES TO ENSURE CODE REQUIRED WORKING CLEARANCES,ACCESS, ETC. FOR PANELS AND SWITCHBOARDS PER C.E.C. 110.26 AND ARTICLE 408.3.3OPERATIONS AND MAINTENANCE MANUALS1.PROVIDE AS-BUILT DRAWINGS.2.PROVIDE THREE SETS OF OPERATION AND MAINTENANCE MANUALS FOR POWER, LIGHTING AND SIGNAL SYSTEMS.3.ASSEMBLE EACH OPERATIONS AND MAINTENANCE MANUALS SET IN STANDARD HARDBACK, 3-RING BINDERS. DO NOT EXCEED BINDER FILL OF 50 PERCENT: i.e., 1-INCH THICKNESS OF PAPER IN 2-INCH BINDER. USE TABULAR DIVIDERS TO ORGANIZE THE MATERIALS. MARK EACH DIVIDER ACCORDING TO(SUB) SECTION NUMBER AND NAME.3.4TESTING1.THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND IMPROPERGROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHERE SUCH TESTS INDICATE FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED, REPAIRED AND RETESTED AT THE CONTRACTOR’S EXPENSE. PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS.2.DEMONSTRATE TO THE OWNER AND THE ARCHITECT, THAT THE ENTIRE INSTALLATION IS COMPLETE, INPROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN PROPERLY AND FULLY EXECUTED.3.5CERTIFICATE OF COMPLETIONACCEPTANCE OF THE CONTRACT FOR THIS WORK INCLUDES THIS GUARANTEE: THE CONTRACTOR GUARANTEES THAT HE HAS PERFORMED THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. CONTRACTOR AGREES TO REPLACE OR REPAIR, AS NEW ANY DEFECTIVE WORK, MATERIALS, OR PART WHICH MAY APPEAR WITHIN ONE YEARS (1) OF FINAL ACCEPTANCE, IF, IN THE OPINION OF THE ARCHITECT OR THE OWNER, THE DEFECT IS DUE TO WORKMANSHIP OR MATERIAL.3.6WARRANTIES, GUARANTEES, CERTIFICATES, ETC.WARRANTIES, GUARANTEES, CERTIFICATES, ETC. THAT ARE FURNISHED AND AVAILABLE FOR EQUIPMENT AND MATERIALS FURNISHED AND INSTALLED UNDER THIS SECTION SHALL BE PROPERLY FILLED OUT AS OF DATE OF ACCEPTANCE OF THE WORK BY THE OWNER AND SHALL BE DELIVERED TO THE ARCHITECT.3.7ACCEPTANCE BY GOVERNING AUTHRITIESUPON THE COMPLETION OF THE ELECTRICAL WORK, AND AS CONDITION OF ITS ACCEPTANCE, THIS CONTRACTOR SHALL OBTAIN FINAL INSPECTIONS AND ACCEPTANCE FROM LOCAL BUILDING INSPECTION AGENCIES, UTILITY COMPANIES AND/OR OTHER GOVERNING AUTHORITIES. DELIVERED TOTHE OWNER AND THE ARCHITECT VERIFICATION OF SUCH ACCEPTANCE.PART 2 - PRODUCTS2.1 WIRING DEVICES1.UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS (BROWN,WHITE, BREY, BEIGE OR IVORY) AS SELECTED BY THE ARCHITECT:WIRING DEVICESLEVITION#HUBBELL#P & S #SINGLE POLE SWITCH1221122120AC1THREE WAY SWITCH1223122320AC3DUPLEX CONV. OUT. 15A526252625262DUPLEX GFI CONV. OUT.GF52622.2DEVICE PLATES1.ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED EQUAL UNLESS OTHERWISE NOTED.2.TELEPHONE (AND COMPUTER SIGNAL) PLATES SHALL BE PROVIDED BY OWNER’S VENDOR UNLESS OTHERWISE NOTED ON PLANS.3.DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE ½” RAISED STEEL PLATES. WEATHERPROOF COVERS TO BE SNAP TYPE COVERS.2.3SUPPORTS1.FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL ELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT.2.ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO METAL WITH MACHINESCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS AND MACHINE SCREWS OR BOLTS.2.4NAMEPLATES & IDENTIFICATIONINSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC. NAMEPLATES SHALLBE SECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPS ROUND HEAD CADMIUM PLATED SELF-TAPPINGSCREWS, BRASS BOLT.2.5GROUNDINGGROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND SPECIFICALLY INCLUDINGSWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC.2.6MAIN SERVICE SWITCHBOARD1.SERVICE SWITCHBOARD SHALL BE AS MANUFACTURED BY GENERAL ELECTRIC, SIEMENS, CUTLER HAMMER, SQUARE D OR APPROVED EQUAL, METAL ENCLOSED UNIT. ARRANGEMENT AND RATINGS OFEQUIPMENT ARE SHOWN ON DRAWINGS. UNIT SHALL MEET ALL UTILITY COMPANY REQUIREMENTS ANDBE APPROVED BY THE ASMAE PRIOR TO PROCUREMENT AND INSTALLATION.2.SWITCHBOARD SHALL BE ENCLOSED STRUCTURE OF CODE GAUGE STEEL PLATES WITH REMOVABLE FRONT. FULL FRONT ACCESS SHALL BE PROVIDED FOR CONNECTIONS AND OPERATIONS. FRONT SECTIONS SHALL BE ATTACHED WIT MACHINE SCREWS, EVENLY SPACED. HINGED DOOR SHALL HAVEVAULT TYPE HANDLES AND LOCKS. UNIT SHALL BE NEMA 3R FOR OUTDOORS INSTALLATION ANDNEMA 1 FOR INDOORS INSTALLATION.3.ALL BUSES SHALL BE COPPER, SIZED TO CONFORM TO UL TO LIMIT TEMPERATURE RISE. ALL BUS CONNECTIONS SHALL BE BOLTED. BUSES SHALL BE BRACED TO WITHSTAND, AS A MINIMUM, THE SHORT CIRCUIT CURRENT INDICATED ON DRAWINGS. BUSES SHALL BE SEQUENCE PHASED AND SHALLRUN FULL HEIGHT.4.PROVIDE “SPACES” INDICATED ON DRAWINGS WITH ALL NECESSARY MOUNTING HARDWARE PERMITTING EASY FUTURE INSTALLATION OF BREAKERS IN THE FIELD.5.PROVIDE INCOMING SERVICE TERMINALS METERING SECTION, CTS, ETC. IN ACCORDANCE WITH THE UTILITY COMPANY AND PLANS.6.PROVIDE A COPPER GROUND BUS.2.7PANEL BOARDUNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE, WITH THE NUMBER AND SIZE OF BREAKERS AS INDICATED ON THE PANEL SCHEDULE. SINGLE POLE, TWO POLE, AND THREE POLE BREAKERS SHALL BE BOLT-ON TYPE. MULTIPLE POLE BREAKERS SHALL HAVE COMMON INTERNAL TRIP CONNECTION. SINGLE POLE BREAKERS SHALL NOT BE TIED AT HANDLES TO FORM MULTIPLE POLE BREAKERS. THE PANEL DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKSSHALL BE KEYED ALIKE AND HAVE TYPEWRITTEN DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICED BY EACH BREAKER. PANELS SHALL HAVE COPPER BUSSING.2.8HVAC SYSTEMS1.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS OF ALL HVAC UNITS, DISCONNECTS AND DEVICES IN FIELD. COORDINATE ROOF PENETRATIONS AND STUB UPS FOR DISCONNECTS WITH ELECTRICAL CONNECTION POINTS ON THE UNITS TO KEEP FLEXIBLE CONDUIT LENGTH TO A MINIMUM (36” MAXIMUM). VERIFY AND CONFIRM WITH THE MECHANICAL CONTRACTOR THE ACTUAL MOUNTING LOCATION ON THE HVAC UNIT FOR THEDISCONNECT PRIOR TO ROUGH-IN. ENSURE CODE REQUIRED WORKING CLEARANCES IN FRONT OF THEDISCONNECTS.2.THE RATING OF THE DISCONNECT SHALL BE SUCH AS TO ENABLE THE LARGEST FUSE SIZE ON THE UNIT NAMEPLATE TO BE INSTALLED IN THE DISCONNECT. VERIFY WITH MECHANICAL CONTRACTOR THIS INFORMATION PRIOR TO BUYING AND INSTALLING THE DISCONNECT. PROVIDE FUSES OF THIS RATING.3.FURNISH AND INSTALL ALL LINE VOLTAGE CONDUITS AND LINE VOLTAGE WIRING (LOW VOLTAGE WIRING AND RELATED CONDUITS BY OTHERS) TO HVAC EQUIPMENT AND ASSOCIATED CONTROLS AND DEVICES AS SHOWN ON THE ELECTRICAL AND MECHANICAL PLANS, UNLESS OTHERWISE NOTED.4.RUN ALL CONDUITS FOR ROOFTOP EQUIPMENT TO CEILING BELOW. SURFACE CONDUIT RUNS ON THEROOF ARE NOT PERMITTED ON THIS PROJECT.5.DISCONNECTS SHALL NOT BE USED AS THROUGH RACEWAYS FOR WIRING NOT DIRECTLY SERVING THEDISCONNECTS. SERVICING OUTLETS SHALL NOT BE MOUNTED ON DISCONNECTS.LIGHTING SYMBOLSELECTRICAL SYMBOLS24 x 48 LIGHT FIXTURESWITCHING SYMBOLS120 VOLT DUPLEX WALL OUTLET+15" A.F.F. TO BOTTOM OF BOXCONDUIT CONCEALED IN WALL OR CEILINGCONDUIT CONCEALED IN FLOOR OR UNDERGROUNDFLEXIBLE CONDUIT FOR LIGHTING ABOVE CEILINGCONDUITMINIMUM SIZE = 12" CTICS = NO. OF #12 WIRESNO TICS = 2#12 UONCONDUITS:ELECTRICAL SPECIFICATIONSELECTRICAL SYMBOL LEGEND24 x 24 LIGHT FIXTURE24 x 24 LIGHT FIXTURERECESSED CAN LIGHT FIXTUREPENDANT LIGHT FIXTUREWALL SCONSE LIGHT FIXTUREEXITILLUMINATED EXIT SIGNCEILING FANSEE DRAWING E-1.1 FOR LIGHT SWITCHLEGEND AND SPECIFICATIONS120 VOLT DUPLEX CEILING OUTLET120 VOLT COUNTERTOP OUTLET+44" A.F.F. TO BOTTOM OF BOX120 VOLT FOURPLEX WALL OUTLET+15" A.F.F. TO BOTTOM OF BOX120 VOLT DUPLEX WALL OUTLETHALF-SWITCHED+15" A.F.F. TO BOTTOM OF BOX120 VOLT FOURPLEX WALL OUTLETHALF-SWITCHED+15" A.F.F. TO BOTTOM OF BOXJJUNCTION BOXFFUSED DISCONNECT SWITCHTTHERMOSTAT+ 48" A.F.F. TO TOP OF CONTROLSSDCEILING MOUNT SMOKE DETECTOROSCEILING MOUNTOCCUPANCY SENSORDSCEILING MOUNT DAYLIGHT SENSORMANUAL MOTORDISCONNECT SWITCHELECTRICAL SUB-PANELPANEL #LIGHTING CONTROL PANELLTGTIMECLOCKTCDUCT SMOKE DETECTORSDDATA WALL OUTLET+15" A.F.F. TO BOTTOM OF BOXTELEPHONE WALL OUTLET+15" A.F.F. TO BOTTOM OF BOXDATA / TELEPHONE WALL OUTLET+15" A.F.F. TO BOTTOM OF BOXTELETELEPHONE BACKBOARDDATADATA PATCH PANELSECURITYSECURITY SYSTEM PANELMUSICSOUND SYSTEM RECEIVERCEILING MOUNT SPEAKERSP120 VOLT WEATHERPROOF OUTLETPSROOF MOUNT PHOTOCELLCOMMUNICATIONS SYMBOLSOFSHEETSTAF9/15/202020-162DRAWNAS SHOWNSCALEDATECHECKEDJOB NO.SHEETREVISIONSBYSLWPROJECT :
<br />CLIENT :
<br />LOCATION :
<br />CRUMBL COOKIES
<br />2624 W. KETTLEMAN LANE, #150
<br />LODI, CA 95242
<br />THEODORE J. BRANDVOLD, ARCHITECT
<br />616 14th STREET, MODESTO, CA 95354
<br />PH (209) 571-8158 FAX (209) 571-8160
<br />JUST DOUGH IT RENEWAL DATEC-25449JATEO
<br />DEONCE
<br />SERLI
<br />D
<br />THEST
<br />OFORNVTARCHITEC.BRANDLI ODACALIF6-30-21INTERIOR TENANT IMPROVEMENT
<br />A.P.N.: 058-03-022
|