(e)PAN L LIGHTING CONTROLS FIXTURE SCHEDULE <br /> (e)40A LOAD TYPE JLAMPSI W LAMP DESCRIPTION MANUFACTURER'S NO. LOAD <br /> CENTER T REMAIN LINE VOLTAGE (HOT, SWITCH HOT, NEUTRAL, GROUND & 3#14 DIMMING) <br /> 4' SURFACE LED WRAP, LITHONIA <br /> PANEL "K" <br /> —D— 0-10V CONTROL CABLE (3#14) A LED 4800L, 0-10V DIMMING #STL4-48L—EZ1 —MVOLT-40K 45 <br /> - <br /> (E)STORAGE (E STAIRWELL �� �� �� �� �� �� <br /> 1_1 0-1 111 „ „ „ „ —N— CAT-5 CONTROL CABLE " <br /> US CEILING MOUNT OCCUPANCY SENSOR SIMILAR TO A WITH A=L <br /> l LED EMERGENCY BALLAST 45 <br /> PC PHOTOCELL W M B <br /> STORAGE <br /> p DIMMING SWITCHLITHONIA ARCHITECTS <br /> 107 COLD STOR GE dre 4 SURFACE LED WRAP, <br /> 108 DIMMING ROOM CONTROLLER B LED 4000L, 0-10V DIMMING #STL4-40L—EZ1 —MVOLT-40K 35 <br /> $dre US ® OUTLET RELAY 20A RATED <br /> g Al NOTES: SIMILAR TO "B" WITH — <br /> 5757 Pacific Avenue <br /> 1. FOR SUBMITTAL INCLUDE FACTORY CONTROL DRAWINGS. B1 LED EMERGENCY BALLAST 35 Suite 226 <br /> D Stockton, CA 95207 <br /> HALLWAY 2. CONDUCT A CONTROLS PRE—CONSTRUCTION MEETING WITH CONTROLS STARTUP <br /> 109 TEAM. PROVIDE AGENDA AND ATTENDEES AS A SUBMITTAL. INCLUDE DEVICE I.D. SURFACE DOWNLIGHT POLY JUNG <br /> somooF p 3 TAGS, PROGRAMMING, CABLE ROUTING, PROGRAM AND TIME SCHEDULES AND DATE C LED CARBONATE 7". #JSF-71N-10—LM-40K-90CR1 13 2000 L Street <br /> OF PROGRAMMING AND TESTING. Suite 125 <br /> 3. —120FRC Sacramento, CA 95811 <br /> 3 D1 AND OCOMMIISSIONI CNTRACTOR TO OMMISSIONING. OPERATIONAVE SYSTEM AL RSOWITHRT OOWNERRPRIOR TO 2'x4' <br /> 2'X4' 720OLM, FLAT PANEL LITHONIA <br /> O A O COMMISSIONING. D LED TROFFER, 0-10V DIMMING #EPANL-2X4-720OLM-80CRI— _ T 209.944.9110 <br /> 40K—FMIN 10—ZT—MVOLT F 209.944.5711 <br /> www.wmbarchitects.com <br /> SIMILAR TO "D" WITH — <br /> D1 LED EMERGENCY BALLAST <br /> $dre $dre <br /> NUMBERED NOTES THIS SHEET: COMBINATION EXIT SIGN/ LITHONIA HCS. <br /> ° Engineering�1 CONDUITS TO CONTAIN UNSWITCHED HOT LEG. SWITCHED HOT LEG, _ _ EGRESS LIGHT UNIT, 90 #LHQM LED R HO SD <br /> U D1 <br /> E 1� NEUTRAL, GROUND AND GRAY AND VIOLET 0-10V DIMMING CONTROL MIN BATTERY BACKUP 50 years <br /> D <br /> INTERCONNECT ALL LIGHTING CONTROL DEVICES (DIMMERS, WALL MOUNT EMERGENCY LITHONIA 2,512 Feather River Dr#F,Stockton,CA 95219 <br /> OCCUPANCY, PHOTOCELL AND LOCAL LIGHTING CONTROLLER) PER . 209-478-8270 I www.hcs-eng.com <br /> 1 A EGRESS LIGHT UNIT 90 //��ELM2L <br /> MANUFACTURER REQUIREMENTS. — — 1r — <br /> EXPANDED KIT HEN MIN BATTERY BACKUP ®Richard C.Smith,PE o richard@hcs-e Bhupendra Patel,PE bhupendraChcs-encs-eng.com <br /> 112 RECONNECT TO EXIST CIRCUIT 13ElizabethA Aguilar elizabeth@hcs-en <br /> SERVING/PREP ° g gcom <br /> ARE US 2 REMOTE EMERGENCY LITHONIA <br /> 10 6 ° _ _ EXTERIOR LIGHT POWERED AFF OELR DWHGXD WT _ PROJECT#2020.265 <br /> BY 9gP <br /> LO I° Gospel Center Rescue <br /> ° D D ELECTRICAL DEMOLITION: Mission Kitchen <br /> 1. REMOVE ALL EXISTING LIGHTING AND LIGHT SWITCHES IN AREA Remodel <br /> WITH NEW LIGHTING SHOWN. <br /> Al lO 445 S San Joaquin St. <br /> 1 Stockton, CA 95203 <br /> EL_ <br /> DIMMING ROOM <br /> CONTROLLER WITH <br /> CAT5 INPUTS FOR <br /> 1 SEE ARCH. DRAWINGS & SPECS LIGHT SWITCHES, <br /> ON "HANGER WIRE DETAIL" MOTION SENSORS, <br /> FASTEN #12 SUSPENSION WIRE FOR ANCHORAGE DETAIL. LINE VOLTAGE DAY LIGHT PHOTOCELL <br /> C AT 2 DIAGONAL CORNERS OF PROVIDE 2 TAUGHT WIRES AT INPUT <br /> EACH 4' LAY—IN FIXTURE & DIAGONAL CORNNERS FOR FIXTURES <br /> FOYER <br /> B B B COVERED ENTRY TO STRUCTURAL MEMBER THAT WEIGHS 56LBS OR LESS LIGHTING FLOOR PLAN <br /> 102 <br /> 101 PROVIDE 4 TAUGHT SUPPORT <br /> WIRES, ONE AT EACH CORNER 120V <br /> D INTEGRAL EARTHQUAKE FOR FIXTURES THAT WEIGH <br /> TO SECOND TO SECOND <br /> MORE THAN 56 LBS. <br /> e CLIP. BEND OUT AS � SWITCH SENSOR <br /> REQUIRED TO ENGAGE FASTEN FIXTURE TO MAIN <br /> MAIN "TEE" RUNNERS. RUNNER W/#8x1/2 SELF- <br /> 1/4" HOLE IN CLIP FOR <br /> SUSPENSION RUNNERS TAPPING TEK SCREWS, ONE I I <br /> E)OUTDOOR D 0 AT EACH CORNER I I 120V P RDECS <br /> COVERED PORCH CEILING TILE OUTLET <br /> 105 0 CONTROLLER <br /> (E)UTILITY CLOSET (E)TOILET T—BAR LAY—IN FLUORESCENT /� Exp.p. 6--30-30—E14303 <br /> ' I 21 <br /> 104 103 LIGHT FIXTURE LINE VOLTAGE < P� <br /> CONTROL & �/ �9TF EcrR <br /> 0-10V DIMMER OF CAO' <br /> CONTROL <br /> MOUNTING DETAIL: LAY-IN FIXTURE WALL MOUNT CEILING CEILING <br /> SCALE: N.T.S. SWITCH WITH OCCUPANCY PHOTOELECTRIC <br /> ON/OFF POWER SENSOR SENSOR <br /> AND RAISE <br /> LOWER CONTROL <br /> NORTH <br /> LIGHTING FLOOR PLAN PUBLISH HISTORY: <br /> SCALE: 1/4°=1'-0" No. DATE PURPOSE <br /> A2/16/21 PLAN CHECK <br /> 0-10V DIMMING <br /> LIGHT FIXTURES <br /> LIGHTING CONTROL DETAIL <br /> SCALE: N.T.S. <br /> WMB PROJECT: <br /> 20-042 <br /> E1 . 1 <br /> 9/16/2020 2:00:42 PM Copyright WMB,Inc. <br /> FILE: K:\2020\301-400\wmb gospel kitchen\E1 1.dwg Mar 05, 2021 — 2:12pm richard <br />