Laserfiche WebLink
Pep Boys #710 <br />from the date the exemption was granted. The tank system owner or operator shall submit <br />documentation of local agency approval to the applicable CUPA for review and possible <br />acceptance in lieu of the assessment specified in subsection (k) of this section. If there is no <br />CUPA, or the CUPA requests that the Department make a determination, the documentation <br />shall be submitted to the Department. Not applicable ---an exemption has not been granted by <br />the CUPA. <br />0)(1) (1) tank system must have secondary containment capable of containing 100 percent of <br />the contents of the tank and ancillary piping volume; and — this requirement is satisfied because <br />all tanks are double walled. See tank specifications in Appendix B. <br />(j)(2) if the tank system is exposed to precipitation, the secondary containment system must <br />have sufficient capacity, in addition to that required in subsection 6)(1) of this section, to <br />contain run-on and infiltration from a 25 -year, 24-hour rainfall event, The tanks are located in a <br />building and are not exposed to precipitation, run-on or infiltration. <br />(j)(3) tank system secondary containment shall be provided with a leak detection system that is <br />designed and operated so that it will detect either the failure of the primary and secondary <br />containment structure or any release of hazardous waste or accumulated liquid in the secondary <br />containment system within 24 hours, or at the earliest practicable time if the existing detection <br />technology or site conditions will not allow detection of a release within 24 hours. The tanks are <br />inspected by Pep Boys employees daily and an inspection log is kept. <br />(k) The tank system assessment shall include all of the following information: <br />(k)(1) tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity (in <br />gallons); See tank configurations, materials of construction and capacities in Table 1. <br />(k)(2) design standard(s), if available, according to which the tank and ancillary equipment were <br />or will be constructed and all of the following information. <br />(k)(2)(A) material of construction; All tanks are made of steel. See Table 1. <br />(k)(2)(B) material thickness and the method used to determine the thickness; thicknesses were <br />measured with an ultrasonic gauge, see Table 11 for measurements. <br />(k)(2)(C) description of tank system piping (material, diameter); this certification is for the tanks <br />only. <br />