My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15040
>
1600 - Food Program
>
PR0538877
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 11:21:27 AM
Creation date
1/7/2022 10:09:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0538877
PE
1623
FACILITY_ID
FA0022336
FACILITY_NAME
SMALLCAKES
STREET_NUMBER
15040
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611020
CURRENT_STATUS
01
SITE_LOCATION
15040 S HARLAN RD
P_LOCATION
03
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION <br /> 1 5/13/21 LFD- 1 ST REVIEW <br /> SMA CAK S BAK RY STOR 5/18/21 LBID- 1ST REVIEW <br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 <br /> WITHIN PARCEL=APN: 196- 11-020 <br /> z <br /> O ' <br /> A05/13/21 LFD- 1 ST REVIEW ria <br /> TENTATIVE IMPROVEMENTS 2019 CALIFORNIA EXISTING BUILDING o <br /> � <br /> PROPOSED TENANTS "SMALLCAKES" BAKERY STORCODEE, Q <br /> OF THIS EXISTING VACANT COMMERCIAL SPACE,WILL HAVE A CUSTOMER CHAPTER 1: SCOPE AND ADMINISTRATION z 1;P'kit �R <br /> SERVING COUNTER,A BAKERY STATION,AN ENCLOSED KITCHEN CLEANING DIVISION I-CALIFORNIA ADMINISTRATION <br /> AREA AND A UNISEX ALL-GENDER BATHROOM. THE PREVIOUS BUILT SPACE " <br /> HAS NO IMPROVEMENTS FROM THE PREVIOUS OCCUPANTS (APNA PUNJAB). EXISTING SCH 40 PVC 3X3X3 TEE 1.1.3.1 NON STATE-REGULATED BUILDINGS, STRUCTURES ANDArm <br /> SANITARY CONNECTION WITH APPLICATIONS. Q 4h W rn � K <br /> CLIENT WILL PROVIDE SAN EWJOAQUIN <br /> APPROVAL <br /> COUNTY ENVIRONMENTAL HEALTH 3"CAP AT END EXCEPT AS MODIFIED BY LOCAL ORDINANCE PURSUANT TO SECTION 1.1.8, r 1 W s <br /> EPARTMENT A PLAN REVIEW APPROVAL LETTER. '� <br /> 05/18/21 L> ID- 1ST COMMENT THE FOLLOWING STANDARDS IN THE CALIFORNIA CODE OF REGULATIONS, e i <br /> TITLE 24,PARTS 2,2.5, 3,4, 5, 6,9, 10 AND 11 SHALL APPLY TO ALL W ` * <br /> THIS SITE HAS A FRONTAGE ROAD(HARLAN RD)ON THE NORTH SIDE OF THE I ? �` <br /> PROPERTY. EXISTING 3" SCH OCCUPANCIES AND APPLICATIONS NOT REGULATED BY A STATE AGENCY. -- <br /> 40 PVC SANITARY EXISTING 3 SCH a 1 03� ' <br /> THE CITY OF LATHROP STORM ACCESS IS NORTH OF THE PROPERTY,WEST OF DRAIN PIPE 40 PVC SANITARY DIVISION II <br /> THE INTERSTATE 5 ON-RAMP. EXISTING SCH 40 PVC DRAIN PIPE <br /> CONNECTS TO 3X3X3 TEE SANITARY REMOVE PIECES OF OLD MOP SCOPE AND ADMINISTRATION <br /> CONNECTION EXISTING HAND b <br /> THE CITY OF LATHROP SEWER ACCESS ON HARLAN RD. EXISTING SANITARY WASH SINK FLOOR SINK&PREPARE AREA <br /> SERVICES (TYP) FOR PROPOSED MOP FLOOR SINK <br /> THE CAL WATER IS AT HARLAN RD. Q Q ; U <br /> SECTION 106-CONSTRUCTION DOCUMENTS •° o �3 <br /> 3 VENT TO ROOF ory <br /> FROM 3X3X3 TEE 106.1 GENERAL. ? a <br /> THE PG&E GAS UTILITY IS AT HARLAN RD. SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS, eG cn o, <br /> 13 <br /> SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, c q <br /> YOU MUST CALL CITY OF LATHROP,CAL WATER,AND PG&E FOR INVESTIGATION AND EVALUATION REPORTS,AND OTHER DATA SHALL BE <br /> PROPOSED TIE-INS/STUB-UPS TO THESE BUILT UTILITIES. SUBMITTED IN TWO OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. v J ' U ¢ w Con rn <br /> EXCEPTION: THE CODE OFFICIAL IS AUTHORIZED TO WAIVE THE W <br /> UTILITY NOTES: o <br /> SUBMISSION OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT <br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY REQUIRED TO BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL z "� <br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE IF IT IS FOUND THAT THE NATURE OF THE WORK APPLIED FOR IS SUCH �. <br /> AREA,EITHER IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT <br /> THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE THAT REVIEWING OF CONSTRUCTION DOCUMENTS IS NOT NECESSARY Z <br /> EXISTING TO OBTAIN COMPLIANCE WITH THIS CODE. a <br /> GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT <br /> LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS 3-COMPARTMENT SINK <br /> ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE.THE SURVEYOR HAS 106.2 CONSTRUCTION DOCUMENTS. - o <br /> NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE WITH SECTIONS U <br /> 106.2.1 THROUGH 106.2.5. o <br /> BUILDING CODE ANALYSIS: <br /> 05/18/21 LBID 106.2.1 CONSTRUCTION DOCUMENTS. <br /> CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON <br /> OCCUPANCY GROUP: GROUP B-1 (CBC 304.1) 2ND COMMENT N - <br /> TYPE OF CONSTRUCTION: SB EXISTING) Q SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO . <br /> FIRE SPRINKLERS: YES 05/18/21 LBID 3RD COMMEN v EXISTING PLUMBING PLAN BE SUBMITTED WHERE APPROVED BY THE CODE OFFICIAL. CONSTRUCTION b <br /> DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE <br /> STORIES: 1 SCALE: 3/4"= 1'-0" LOCATION NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW ^ °' N_ o <br /> BUILDING HEIGHT: 10'-0" � <br /> ALLOWABLE FLOOR AREA: 1,920ftz IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE <br /> AND RELEVANT LAWS,ORDINANCES,RULES AND REGULATIONS,AS O <br /> FLOOR AREA: 1,920ftz DETERMINED BY THE CODE OFFICIAL. THE WORK AREAS SHALL BE <br /> A05/18/21 LBID 4TH COMMENT SHOWN. <br /> OCCUPANCY LOAD PER(CBC 1004-TABLE 1004.5) PERSONS O <br /> 106.2.2 FIRE PROTECTION SYSTEM(S) SHOP DRAWINGS. v1 w M <br /> ACCESSORY STORAGE AREAS 1 SHOP DRAWINGS FOR THE FIRE PROTECTION SYSTEM(S) SHALL BE W O Q <br /> ASSEMBLY WITHOUT FIXED SEATS (STANDING SPACES) 42 SUBMITTED TO INDICATE CONFORMANCE WITH THIS CODE AND THE Q� <br /> BUSINESS AREAS 6 CONSTRUCTION DOCUMENTS AND SHALL BE APPROVED PRIOR TO THE Q O Q <br /> KITCHEN,COMMERCIAL 3 START OF SYSTEM INSTALLATION. SHOP DRAWINGS SHALL CONTAIN <br /> TOTAL OCCUPANCY LOAD 52 INFORMATION AS REQUIRED BY THE REFERENCED INSTALLATION <br /> STANDARDS IN CHAPTER 9 OF THE CALIFORNIA BUILDING CODE. Q V1 Q N <br /> 05/18/21 LBID 4TH COMMENT Qz <br /> 19 CALIFORNIA BUILDING CODE <br /> CHAPTER 10-MEANS OF EGRESS Q x U O <br /> SECTION 1004-OCCUPANT LOAD W <br /> 1004.1 DESIGN OCCUPANT LOAD. IN DETERMINING MEANS OF EGRESS O <br /> REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM MEANS OF EGRESS <br /> FACILITIES ARE PROVIDED SHALL BE DETERMINED IN ACCORDANCE WITH O Q� <br /> THIS SECTION AND TABLE 1004.5 <br /> (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT). <br /> Q O <br /> � Woo <br /> UNAUTHORIZED CHANGES&USES: <br /> The design firm preparing these plans will not be responsible for,or liable for, <br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in <br /> PERMIT NOTE: writing and must be approved by the preparer of these plans. <br /> The issuance of a permit or approval of plans or specifications shall not be deemed or CHECKED BY: J.AGUIRRE (E.O.R.) <br /> construed to be a permit for an approval of any violation of any of the provisions of the G.MENDOZA <br /> California state building codes or local ordinances. CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS <br /> Construction contractor agrees that in accordance with generally acepted construction G.MENDOZA <br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: PHANTOM DESIGNS <br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1/4"= F-0" <br /> DESIGN NOTE: including safety of all persons and property;that this requirement shall be made to apply <br /> Electronic versions of the line work on this plan may not be consistent with other continuously and not to be limited to normal working hours, and construction contractor DATE: 04/30/2021 <br /> dimensions,notes,details,or descriptions which control the intent design. electronic 41 0 21 41 further agrees to defend,imdemnify and hold design professional harmless from any <br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this <br /> improvements in the field. project, except liability arising from the sole negligence of the design professional. <br /> SCALE: 1/4"= 1'-0" X7 ,00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.