REVISIONS
<br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION
<br /> 115/13/21 LFD- 1 ST REVIEW
<br /> SMA CAK S BAK RY STOR 05/18/21 LBID- 1ST REVIEW
<br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 1F
<br /> WITHIN PARCEL=APN: 196- 11-020 54 ,
<br /> of
<br /> 59'-0"
<br /> A05/13/21 LFD- 1 ST REVIEW I f
<br /> TENTATIVE IMPROVEMENTS 2019 CALIFORNIA EXISTING BUILDING o
<br /> PROPOSED TENANTS "SMALLCAKES" BAKERY STORE, o CODE
<br /> OF THIS EXISTING VACANT COMMERCIAL SPACE WILL HAVE A CUSTOMER N Q `
<br /> ' � ° CHAPTER 1: SCOPE AND ADMINISTRATION z �'
<br /> SERVING COUNTER A BAKERY STATION'AN ENCLOSED KITCHEN CLEANINGI -
<br /> "' D DIVISION I-CALIFORNIA ADMINISTRATION
<br /> AREA AND A UNISEX ALL-GENDER BATHROOM. THE PREVIOUS BUILT SPACE
<br /> HAS NO IMPROVEMENTS FROM THE PREVIOUS OCCUPANTS (APNA PUNJAB). o w a d 1.1.3.1 NON STATE-REGULATED BUILDINGS, STRUCTURES AND
<br /> cn
<br /> CLIENT WILL PROVIDE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH Xx d 3 APPLICATIONS. 191m
<br /> \ W P'.' � , D EXCEPT AS MODIFIED BY LOCAL ORDINANCE PURSUANT TO SECTION 1.1.8 r 1 Y
<br /> EPARTMENT A PLAN REVIEW APPROVAL LETTER. �` H ` y
<br /> 05/18/21 LAID- 1ST COMMENT W U THE FOLLOWING STANDARDS IN THE CALIFORNIA CODE OF REGULATIONS, is
<br /> a TITLE 24,PARTS 2,2.5, 3,4, 5, 6,9, 10 AND 11 SHALL APPLY TO ALL
<br /> THIS SITE HAS A FRONTAGE ROAD(HARLAN RD)ON THE NORTH SIDE OF THE W p CN,
<br /> PROPERTY. Ga
<br /> U OCCUPANCIES AND APPLICATIONS NOT REGULATED BY A STATE AGENCY. *,
<br /> �
<br /> THE CITY OF LATHROP STORM ACCESS IS NORTH OF THE PROPERTY,WEST OF DIVISION II
<br /> THE INTERSTATE 5 ON-RAMP.
<br /> EXISTING D SCOPE AND ADMINISTRATION r
<br /> ELECT.PANEL
<br /> THE CITY OF LATHROP SEWER ACCESS ON HARLAN RD. g y
<br /> SECTION 106-CONSTRUCTION DOCUMENTS 0 o
<br /> THE CAL WATER IS AT HARLAN RD. q © p, ri. U
<br /> 106.1 GENERAL. 3 V
<br /> THE PG&E GAS UTILITY IS AT HARLAN RD. SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS,
<br /> SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS,
<br /> YOU MUST CALL CITY OF LATHROP,CAL WATER,AND PG&E FOR D p INVESTIGATION AND EVALUATION REPORTS,AND OTHER DATA SHALL BE t ^ i 0 p -x '-
<br /> PROPOSED TIE-INS/STUB-UPS TO THESE BUILT UTILITIES. ° SUBMITTED IN TWO OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. `'+ �" ¢ w �!' `�
<br /> EXCEPTION: THE CODE OFFICIAL IS AUTHORIZED TO WAIVE THE W
<br /> UTILITY NOTES:
<br /> SUBMISSION OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT
<br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY y� o REQUIRED TO BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL Z '�
<br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE W pIF ITIS FOUND THAT THE NATURE OF THE WORK APPLIED FOR IS SUCH
<br /> THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE EXISTING BUILDING Fq ° THAT REVIEWING OF CONSTRUCTION DOCUMENTS IS NOT NECESSARY Z
<br /> AREA,EITHER IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT PROPOSED BAKERY FLOOR CEILING HEIGHT= 10'-0" p TO OBTAIN COMPLIANCE WITH THIS CODE.
<br /> GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT °
<br /> LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS (1,823 sq.ft.)
<br /> ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE.THE SURVEYOR HAS 106.2 CONSTRUCTION DOCUMENTS. e a
<br /> NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. ` D CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE WITH SECTIONS Uh
<br /> y 106.2.1 THROUGH 106.2.5. o
<br /> BUILDING CODE ANALYSIS:
<br /> 05/18/21 LBID ° 106.2.1 CONSTRUCTION DOCUMENTS. 0
<br /> 1 (1535
<br /> CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON N
<br /> OCCUPANCY GROUP: GROUP B-1 (CBC 304.1) 2ND COMMENTT
<br /> SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO au .
<br /> TYPE OF CONSTRUCTION: SB EXISTING) Q 05/18/21 LBID 3RD COMMEN BE SUBMITTED WHERE APPROVED BY THE CODE OFFICIAL. CONSTRUCTION °' v
<br /> FIRE SPRINKLERS: YES
<br /> DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE e N
<br /> STORIES: 1 LOCATION NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW
<br /> BUILDING HEIGHT: 10'-0"
<br /> ALLOWABLE FLOOR AREA: 1,920ftz p IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE o.
<br /> AND RELEVANT LAWS,ORDINANCES,RULES AND REGULATIONS,AS
<br /> FLOOR AREA: 1,920ftz ° DETERMINED BY THE CODE OFFICIAL. THE WORK AREAS SHALL BE
<br /> A05/18/21 LBID 4TH COMMENT SHOWN.
<br /> OCCUPANCY LOAD PER(CBC 1004-TABLE 1004.5) PERSONS O
<br /> 106.2.2 FIRE PROTECTION SYSTEM(S) SHOP DRAWINGS.
<br /> ACCESSORY STORAGE AREAS 1 - SHOP DRAWINGS FOR THE FIRE PROTECTION SYSTEM(S) SHALL BE V1 O Q
<br /> ASSEMBLY WITHOUT FIXED SEATS (STANDING SPACES) 42 ADr=T BUILDING SPACE SUBMITTED TO INDICATE CONFORMANCE WITH THIS CODE AND THE
<br /> BUSINESS AREAS 6
<br /> CONSTRUCTION DOCUMENTS AND SHALL BE APPROVED PRIOR TO THE
<br /> KITCHEN,COMMERCIAL 3
<br /> TOTAL OCCUPANCY LOAD 3 START OF SYSTEM INSTALLATION. SHOP DRAWINGS SHALL CONTAIN
<br /> EXISTING SPRINKLER PLAN INFORMATION AS REQUIRED BY THE REFERENCED INSTALLATION Z N
<br /> STANDARDS IN CHAPTER 9 OF THE CALIFORNIA BUILDING CODE. V1
<br /> 05/18/21 LBID 4TH COMMENT LEGEND SCALE: 1/4"= l'-0" z O
<br /> 19 CALIFORNIA BUILDING CODE 1Q 05/13/21 LFD- 1ST REVIEW W
<br /> CHAPTER 10-MEANS OF EGRESS SPRINKLER HEAD 2018 INTERNATIONAL FIRE CODE
<br /> SPRINKLER LINE CHAPTER 9-FIRE PROTECTION AND LIFE SAFETY SYSTEMS
<br /> SECTION 1004-OCCUPANT LOAD W o
<br /> 1004.1 DESIGN OCCUPANT LOAD. IN DETERMINING MEANS OF EGRESS O
<br /> REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM MEANS OF EGRESS SECTION 903 -AUTOMATIC SPRINKLER SYSTEMS
<br /> FACILITIES ARE PROVIDED SHALL BE DETERMINED IN ACCORDANCE WITH 903.6-WHERE REQUIRED IN EXISTING BUILDINGS AND STRUCTURES
<br /> AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED IN EXISTING
<br /> THIS SECTION AND TABLE 1004.5
<br /> (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT). BUILDINGS AND STRUCTURES WHEN REQUIRED IN CHAPTER 11.
<br /> NOTES:
<br /> THIS EXISTING VACANT COMMERCIAL SPACE IS EQUIPPED WITH A FIRE
<br /> SUPPRESSION SYSTEM,THERE IS NO MODIFICATION TO THE TENANT
<br /> IMPROVEMENT THAT AFFECTS THE SPRINKLER COVERAGE.
<br /> TENANT/OCCUPANT/OWNER SHALL HAVE THE RESPONSIBILITY TO
<br /> ENSURE THAT THE EISTING FIRE SUPPRESSION SYSTEM IS TESTED AND
<br /> ACCEPTED BY THE (AHJ)FIRE DISTRICT. THE PROJECT INFORMATION h� Q
<br /> ON THE COVER SHEET STATES THAT THE STRUCTURE IS EXISTING
<br /> VACANT COMMERCIAL SPACE TO BECOME A PROPOSED BAKERY STORE
<br /> THAT HAS EXISTING SPRINKLER SYSTEM. Q r O Z
<br /> UNAUTHORIZED CHANGES&USES:
<br /> The design firm preparing these plans will not be responsible for,or liable for,
<br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in
<br /> PERMIT NOTE: writing and must be approved by the preparer of these plans.
<br /> The issuance of a permit or approval of plans or specifications shall not be deemed or CHECKED BY: J.AGUIRRE (E.O.R.)
<br /> construed to be a permit for an approval of any violation of any of the provisions of the G.MENDOZA
<br /> California state building codes or local ordinances. CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS
<br /> Construction contractor agrees that in accordance with generally acepted construction G.MENDOZA
<br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: PHANTOM DESIGNS
<br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1/4"= l'-0"
<br /> DESIGN NOTE: including safety of all persons and property;that this requirement shall be made to apply
<br /> Electronic versions of the line work on this plan may not be consistent with other continuously and not to be limited to normal working hours, and construction contractor DATE: 04/30/2021
<br /> dimensions,notes,details,or descriptions which control the intent design. electronic 41 0 21 41 further agrees to defend,imdemnify and hold design professional harmless from any
<br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this
<br /> improvements in the field. project, except liability arising from the sole negligence of the design professional.
<br /> SCALE: 1/4"= 1'-0" X8 , 0