REVISIONS
<br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION
<br /> 115/13/21 LFD- 1 ST REVIEW
<br /> SMA CAK S BAK RY STOR 05/18/21 LBID- 1ST REVIEW
<br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 1F
<br /> WITHIN PARCEL=APN: 196- 11-020 54 ,
<br /> of
<br /> 1 05/13/21 LFD- 1 ST REVIEW 59'-0" I W %.
<br /> TENTATIVE IMPROVEMENTS 2019 CALIFORNIA BUILDING CODE o
<br /> PROPOSED TENANTS "SMALLCAKES" BAKERY STORE, #17 BREAKER— 220v 220v CHAPTER 10 MEANS OF EGRESS
<br /> OF THIS EXISTING VACANT COMMERCIAL SPACE,WILL HAVE A CUSTOMER GFCI #14 BREAKER— — — — J 1013.5 INTERNALLY ILLUMINATED EXIT SIGNS. Q "OF-ER
<br /> EXISTING p Z
<br /> SERVING COUNTER,A BAKERY STATION,AN ENCLOSED KITCHEN CLEANING Z — — #14 BREAKER — — — — ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMINESCENCE
<br /> RESTROOM(52.5 ft) _ _ _ _ _ _ _#19_BREAKER_ _
<br /> EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924
<br /> AREA AND A UNISEX ALL-GENDER BATHROOM. THE PREVIOUS BUILT SPACE CEILING HEIGHT= 10'-0" � _#12 BREAKER— — J �
<br /> AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S -
<br /> HAS NO IMPROVEMENTS FROM THE PREVIOUS OCCUPANTS (APNA PUNJAB). ❑ PROPOSED KITCHEN F_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _#13 BREAKER — — — — — W
<br /> CEILING HEIGHT= 10'-0" #21BREAKERL INSTRUCTIONS AND CHAPTER 27.EXIT SIGNS SHALL BE ILLUMINATED AT pC } I
<br /> � - - - - - - - - - - - - - - - — `} to "4,
<br /> CLIENT WILL PROVIDE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH (77 ft) — — — — — — — — — — — — — #15 BREAKER -- -— — - - - - EXISTING OUTLET ALL TIMES. nr, ?
<br /> EPARTMENT A PLAN REVIEW APPROVAL LETTER. EXISTING �— — — — — — — — — — — — — — —#11 BREAKER— — ON CEILING(10'-0") 'b ej
<br /> 05/18/21 LAID- I ST COMMENT o
<br /> ELECT.PANEL CHAPTER 27 ELECTRICAL ,+
<br /> � � � W �
<br /> THIS SITE HAS A FRONTAGE ROAD(HARLAN RD)ON THE NORTH SIDE OF THE 3'-0"INTER (DOOR LOCKED) = OZ�v� 2701.1 SCOPE. vs
<br /> DOOR o IP4THE PROVISIONS OF THIS CHAPTER AND NFPA 70 SHALL GOVERN THE r
<br /> PROPERTY. OO W 4,0 #�
<br /> N DESIGN,CONSTRUCTION,ERECTION AND INSTALLATION OF THE a ++
<br /> THE CITY OF LATHROP STORM ACCESS IS NORTH OF THE PROPERTY,WEST OF \\\ I I N �I❑ ELECTRICAL COMPONENTS,APPLIANCES,EQUIPMENT AND SYSTEMS USED
<br /> THE INTERSTATE 5 ON-RAMP. \\ — — — — — — — — — — — — — J PROPOSED BAKERY FLOOR �i I IN BUILDINGS AND STRUCTURES COVERED BY THIS CODE. THE CALIFORNIA
<br /> — — — — — — — — — — — — — — — — CEILING HEIGHT= 10'-0" p D FIRE CODE,THE INTERNATIONAL PROPERTY MAINTENANCE CODE AND NFPA r
<br /> THE CITY OF LATHROP SEWER ACCESS ON HARLAN RD. (1,502 ft) d� 70 SHALL GOVERN THE USE AND MAINTENANCE OF ELECTRICAL J '
<br /> \ � w COMPONENTS,APPLIANCES,EQUIPMENT AND SYSTEMS. THE CALIFORNIA ?P ,- 0 0 �' ct
<br /> THE CAL WATER IS AT HARLAN RD. \\ pad H EXISTING OUTLET EXISTING BUILDING CODE AND NFPA 70 SHALL GOVERN THE ALTERATION, © 5 - 131
<br /> -� a; ON CEILING(10'-0") REPAIR RELOCATION REPLACEMENT AND ADDITION OF ELECTRICAL31-Off 1 Q c
<br /> THE PG&E GAS UTILITY IS AT HARLAN RD. INTERIOR DOOM � WPI 0 0
<br /> COMPONENTS,APPLIANCES,OR EQUIPMENT AND SYSTEMS. EMERGENCY •� a
<br /> WW x� _ POWER SYSTEMS AND STANDBY POWER SYSTEMS SHALL COMPLY WITH °' ` � `� `� F
<br /> SECTIONS 2702.1.1 THROUGH 2702.1.8. ~�
<br /> YOU MUST CALL CITY OF LATHROP,CAL WATER,AND PG&E FOR I o ❑ 'x ti
<br /> PROPOSED TIE-INS/STUB-UPS TO THESE BUILT UTILITIES. O I I I� �� ❑ N D _ �" ¢ w `" Cn
<br /> -� 2702.2.6 EXIT SIGNS r I 1
<br /> ❑ - /I \� a � � o EMERGENCY POWER SHALL BE PROVIDED FOR EXIT SIGNS AS REQUIRED IN F�"1 v
<br /> UTILITY NOTES. I INT IO OOR w I o y d = SECTION 1013.6.3. THE SYSTEM SHALL BE CAPABLE OF POWERING THE
<br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY - w �C d I / \ I a p - REQUIRED LOAD FOR A DURATION OF NOT LESS THAN 90 MINUTES. Z
<br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE
<br /> THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE Z ¢ W /// \\\ I I M D Z
<br /> AREA,EITHER IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT w Q
<br /> GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT W x Q I PROPOSED OFFICE D o NFPA 70
<br /> LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS A 3 W I CEILING HEIGHT= 10'-0"�
<br /> ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE.THE SURVEYOR HASW W 144 ftZ i
<br /> NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES.
<br /> ( ) ARTICLE 210-BRANCH CIRCUITS O a
<br /> 210.8(B)OTHER THAN DWELLING UNITS.
<br /> a EXISTING OUTLET a
<br /> BUILDING CODE ANALYSIS: ° ' ON CEILING(10'-0") ALL SINGLE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50
<br /> w D AMPERES OR LESS AND THREE-PHASE RECEPTACLES RATED 150 VOLTS TO v
<br /> A05/18/21 LBID GROUND OR LESS, 100 AMPERES OR LESS INSTALLED IN THE FOLLOWING CJ
<br /> OCCUPANCY GROUP: GROUP B-1 (CBC 304.1) 2ND COMMENT LOCATIONS SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER
<br /> TYPE OF CONSTRUCTION: SB EXISTING) 05/18/21 LBID 3RD COMME
<br /> PROTECTION FOR PERSONNEL. o,
<br /> FIRE SPRINKLERS: YES N e
<br /> o,
<br /> STORIES: 1 BATHROOM SINKS. n' Q
<br /> PROPOSED STORAGE ROOM EXISTING 4"x4"
<br /> BUILDING HEIGHT: 10'-0" WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8 M(6 FT)FROM THE TOP 3 _,
<br /> CEILING HEIGHT= 10'-0" STEEL POLE O
<br /> (100 ftZ) FROM FLOOR D INSIDE EDGE OF THE BOWL OF THE SINK
<br /> ALLOWABLE FLOOR AREA: 1,920ftZ °1 a•
<br /> FLOOR AREA: 1,920ftZ
<br /> PROPOSED HALLWAY THRU CEILING NOTE:
<br /> A05/18/21 LBID 4TH COMMENT 5ft WIDE D ALL ELECTRIC WIRES RE INSTALLED TYP. TO CITY OF LATHROP STANDARDS
<br /> O
<br /> OCCUPANCY LOAD PER(CBC 1004-TABLE 1004.5) PERSONS
<br /> ACCESSORY STORAGE AREAS 1
<br /> ASSEMBLY WITHOUT FIXED SEATS (STANDING SPACES) 42 T BUILDING SP w
<br /> BUSINESS AREAS 6
<br /> KITCHEN,COMMERCIAL 3 Q O
<br /> TOTAL OCCUPANCY LOAD 52 PROPOSED ELECTRICAL PLAN "C
<br /> 05/18/21 LBID 4TH COMMENT LEGEND SCALE: 1/4"= l'-0"
<br /> 19 CALIFORNIA BUILDING CODE w v
<br /> NEW DUPLEX AC OUTLET
<br /> CHAPTER 10-MEANS OF EGRESS 220v 120VCA
<br /> Z Q U O
<br /> SECTION 1004-OCCUPANT LOAD 0
<br /> NEW DUPLEX AC OUTLET 04 C)
<br /> 1004.1 DESIGN OCCUPANT LOAD. IN DETERMINING MEANS OF EGRESS 220V �I O
<br /> REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM MEANS OF EGRESS rC
<br /> FACILITIES ARE PROVIDED SHALL BE DETERMINED IN ACCORDANCE WITH — — — — — NEW WIRING O Q
<br /> THIS SECTION AND TABLE 1004.5
<br /> (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT). NOTE: ALL EXISTING ELECTRICAL GREYED
<br /> OUT TO DIFFERENTIATE FROM PROPOSED
<br /> ELECTRICAL. SEE SHEET E1.0 FOR EXISTING
<br /> ELECTRICAL PLAN
<br /> Q O
<br /> Q Aa pz �
<br /> � w
<br /> UNAUTHORIZED CHANGES&USES:
<br /> The design firm preparing these plans will not be responsible for,or liable for,
<br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in
<br /> PERMIT NOTE: writing and must be approved by the preparer of these plans.
<br /> The issuance of a permit or approval of plans or specifications shall not be deemed or CHECKED BY: J.AGUIRRE (E.O.R.)
<br /> construed to be a permit for an approval of any violation of any of the provisions of the G.MENDOZA
<br /> California state building codes or local ordinances. CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS
<br /> Construction contractor agrees that in accordance with generally acepted construction G.MENDOZA
<br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: PHANTOM DESIGNS
<br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1/4"= l'-0"
<br /> DESIGN NOTE: including safety of all persons and property;that this requirement shall be made to apply
<br /> Electronic versions of the line work on this plan may not be consistent with other continuously and not to be limited to normal working hours, and construction contractor DATE: 04/30/2021
<br /> dimensions,notes,details,or descriptions which control the intent design. electronic 41 0 21 41 further agrees to defend,imdemnify and hold design professional harmless from any
<br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this
<br /> improvements in the field. project, except liability arising from the sole negligence of the design professional.
<br /> SCALE: 1/4"= 1'-0" ELO