Laserfiche WebLink
REVISIONS <br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION <br /> SMA CAK S BAK RY STOR I I <br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 _ <br /> WITHIN PARCEL=APN: 196- 11-020 <br /> o <br /> O <br /> z <br /> W W <br /> a ' <br /> DocuSign Envelope of pe ID:7512A21C-24E6-4182-8A53-EF5E16599092 DocuSign Envelope ID:7512A21C-24E6-4182-8A53-EF5E16599092 <br /> Cit UNREASONABLE HARDSHIP REQUEST <br /> Leh ro; ` ; 16 <br /> p� OPTION A-EXISTING ACCESSIBLE ELEMENTS MEET FULL COMPLIANCE (zl r 2 <br /> Unreasonable Hardship Request (continued) _ -9003H <br /> Community Development Department 390 Towne Centre Drive-Lathrop, CA 95330 1. THIS BUILDING, 15040 HARLAN ROAD,LATHROP,CA IS AN EXISTING BUILDING. THIS EXISTING BUILDINGS <br /> Building Division Phone (209) 941-7270-Fax(209) 941-7268 Additional Information for Option B ENTRANCE IS A GLASS COMMERCIAL DOOR THAT IS 3' (36 INCHES)WIDE FROM FRAME TO FRAME. <br /> Describe how equivalent facilitation will be provided for features identified, in#8, above: (Continue on separate REQUIREMENT 1111-404.2.3 CLEAR WIDTH SAYS: DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32" <br /> www.ci.lathop.ca.us �, U ❑ <br /> sheet as needed) MINIMUM,THIS MEANS WE ARE WITHIN REQUIREMENTS BY 4 INCHES. ❑ ❑ ❑ <br /> _an .,. ❑ o � c <br /> UNREASONABLE HARDSHIP REQUEST NIA 2. THE REGISTER COUNTER WILL BE 34 INCHES HIGH MAX. THE REQUIREMENTS ARE:11B-308.3.2. OBSTRUCTED 815 <br /> =W a ? U <br /> HIGH REACH:WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT Gl c o baa _l �I <br /> AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34" MAX, " U W a <br /> Check the ONE option, from the following three options, that applies to this request: p Cr <br /> WHICH MEANS WE ARE WITHIN REQUIREMENTS. 5 <br /> A This project does not exceed the valuation threshold* per 2019 CBC§11B-202.4 Ex. #8; or r t'1 C 5 <br /> ® ) p j p ,� C J u ¢ w <br /> 3. THE ISLE-WAYS ARE FROM 41-011 (48 INCHES)TO 5'-0" (60 INCHES). THE REQUIREMENTS ARE: 1111-305.3 SIZE <br /> ❑ B) This project exceeds the valuation threshold* per 2019 CBC§11B-202.4 Ex. #8; or THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30" MIN.BY 48" MIN.,WHICH MEANS WE ARE WITHIN W <br /> REQUIREMENTS. <br /> ElC) This project contains elements for which documentation is provided showing that full compliance with For Option C Only � <br /> the applicable accessibility requirements is technically infeasible due to either Technical Infeasibility, per 4. THE WATER CLOSET OS SET 18 INCHES AWAY FROM THE LEFT-SIDE WALL,TO ITS CENTER-LINE,AND SET TO Z 'r <br /> On a separate page: THE REAR WALL. THE REQUIREMENTS ARE: LOCATION THE WATER CLOSET SHALL BE POSITIONED <br /> 2019 CBC §118-202.3 Ex.#2, or due to Legal Constraints. Q _ <br /> 1. Provide a description for each element that meets the 2019 Code definition of Technically Infeasible. WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTER-LINE OF THE WATER CLOSET SHALL Z <br /> Project Address 15040 S Harlan Road,Lathrop 95330 Plan Check Number BE 17"MIN.TO 18" MAX.,WHICH MEANS WE ARE WITHIN REQUIREMENTS. <br /> 2. Describe why full access compliance is technically infeasible for each element. <br /> 1. Describe the use of the subject facility: 5. THE TOILET MANEUVERING SPACE FOR WHEELCHAIR ACCESS IS 65 INCHES DEEP AND 78 INCHES WIDE FROM <br /> Cupcake bakery 3. If applicable, describe the legal constraint that would preclude complete access compliance. C) p <br /> FRONT OF THE WATER CLOSET. THE REQUIREMENTS ARE: 11B-604.8.1.1.2 MANEUVERING SPACE WITH U <br /> 2. Cost of construction proposed under this permit: (Excluding accessibility upgrades as $ 60 000.00 SIDE-OPENING DOOR IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A DOOR LOCATED IN THE SIDE o <br /> allowed by CBC 11B-202.4) ' WALL OR PARTITION,EITHER IN-SWINGING OR OUT-SWINGING,A MINIMUM 60" WIDE AND 6011DEEP <br /> 3. List the total valuation (cost) for each project along the same path of travel**over the last three years: (The MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET, WHICH MEANS WE ARE WITHIN <br /> summation of the costs below combined with the current proposed cost, item #2, above, may trigger option B Any request for an unreasonable hardship must address all of the above-listed criteria for the applicable option. REQUIREMENTS. o ; 0 <br /> requirements.) �y w °f ' <br /> �, <br /> Emphasis must be placed on the elements that provide the greatest improvements to disabled access. o <br /> 6. THE SINK IS POSITIONED FROM THE RIGHT WALL TO CENTER-LINE AT 18 INCHES. THE REQUIREMENT IS: <br /> Project Cost (W/o � q <br /> Permit Number: Project Description: access features) Disproportionate cost must be established to qualify for a hardship. 11B-606.6 ADJACENT SIDE WALL OR PARTITION LAVATORIES,WHEN LOCATED ADJACENT TO A SIDE WALL OR w n, a <br /> PARTITION, SHALL BE A MINIMUM OF 18" TO THE CENTERLINE OF THE FIXTURE,WHICH MEANS WE ARE <br /> $ 0.00 All details of any unreasonable hardship finding will be recorded and kept on file by the City and are subject to WITHIN REQUIREMENTS. <br /> $ ratification through an appeals process. O v <br /> $ 7. THE UNISEX ALL-GENDER RESTROOM SHALL HAVE A SIGN ON THE DOOR, TYPICAL SIZE AND COLOR FOR ADA <br /> * <br /> 4. Total cost of construction over the last three years plus proposed cost of this project: $ 0.00 Division of the State Architect COMPLIANCE FOR ALL PERSONS. O <br /> 5. 20% of total construction cost (0.20 X Line 4) $ ** Path of travel as defined in CBC Chapter 2 includes the toilet and bathing facilities,telephones, drinking fountains M <br /> THIS SHEET ALONG WITH THE UNREASONABLE HARDSHIP FORMS ATTACHED TO THE LEFT AND SHEET A8.0 ADA <br /> 6. Accessible Elements: Is element accessible? is element to be altered? Cost of alteration and signs serving the area of work <br /> COMPLIANCE PLAN, SHOULD BE ENOUGH INFORMATION THAT THIS PREVIOUSLY BUILT BUILDING SPACE IS ADAII <br /> Accessible Route Y N Y N $ THE FOLLOWING SIGNATURES ARE REQUIRED FOR ALL APPLICATIONS. COMPLIANT AND THERE SHOULD BE NO FURTHER MEANS FOR INVESTIGATING SUCH BEYOND LICENSED CITY pL <br /> Parking Y N YN $ INSPECTORS AND LICENSED CODE ENFORCERS. Q <br /> Signatures: I hereby acknowledge that the above is true to the best of my knowledge. As the owner of the property or <br /> Primary Entrance Y N Y N $ Q / Z <br /> tenant space, or an authorized agent representing the owner, by signing below I am acknowledging that I understand l2l Qr <br /> Restrooms (Mand F} Y N Y N $ C N <br /> Telephones Y N Y N $ that although the project is in compliance with the California Building Code requirements, the limited disabled access <br /> upgrades shown on this farm will not limit or absolve my liability under the Americans with Disability Act. <br /> Drinking Fountains Y N Y N $ O <br /> Signage Y N Y N $ 40.00 Designer: GABRIEL MENDOZA-PHANTOM DESIGNS Ga-hy�eL Me.L l a_ 03/06/2021 1 O <br /> Total of proposed improvements along the path of travel: (Attach detailed cost estimate) $ 40.00 Print �; Date <br /> 7. Total cost of making building alterations which would achieve full compliance $ Ambrose Brisco3/6/2021 P4 W O 0 <br /> 8. Specify existingnon-com plying accessibilityfeatures for which a hardship is requested: Property Owner: ru�rbst,A9A9 �26 W <br /> p y p Y g p q CBOF7 9A9664426... � O <br /> 9. Note:Foroption A: Describe how existing accessible elements meet full compliance on a separate sheet. Field Print Signature Date <br /> verification shall be required to confirm full compliance with no worked listed-zero cost for full compliance. O <br /> PLEASE INCORPORATE THIS COMPLETED AND <br /> See attached plan. <br /> SIGNED FORM INTO THE BODY OF THE PLANS. <br /> W � <br /> M <br /> z c <br /> W <br /> UNAUTHORIZED CHANGES& USES: <br /> The design firm preparing these plans will not be responsible for, or liable for, <br /> unauthorized changes to or uses of these plans.All changes to these plans MUST be in <br /> PERMIT NOTE: writing and must be approved by the preparer of these plans. <br /> The issuance of a permit or approval of plans or specifications shall not be deemed or CHECKED BY: J.AGUIRRE (E.O.R.) <br /> construed to be a permit for an approval of any violation of any of the provisions of the G.MENDOZA <br /> California state building codes or local ordinances. CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS <br /> J Construction contractor agrees that in accordance with generally acepted construction DRAWN BY: PHANTOM DESIGNS <br /> practices, construction contractor will be required to assume sole and complete <br /> Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: N.T.S. <br /> DESIGN NOTE: includingsafety of all persons and property;that this requirement shall be made to apply <br /> Electronic versions of the line work on this plan may not be consistent with other y p p p y' q pp y DATE: 04/30/2021 <br /> continuously and not to be limited to normal working hours, and construction contractor <br /> dimensions,notes,details, or descriptions which control the intent design. electronic further agrees to defend, imdemnify and hold design professional harmless from any <br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this <br /> improvements in the field. ro'ect, except liability arising from the sole negligence of the design professional. <br /> ADA260 <br />