REVISIONS
<br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION
<br /> 115/13/21 LFD- 1 ST REVIEW
<br /> SMA CAK S BAK RY STOR 05/18/21 LBID- 1ST REVIEW
<br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 1F
<br /> WITHIN PARCEL=APN: 196- 11-020 54 ,
<br /> of
<br /> 59'-0"
<br /> A05/13/21 LFD- 1 ST REVIEW T-0" 11'-0" 28'-0" 3'-7" 3'-7" 5'-0"7�t :1
<br /> TENTATIVE IMPROVEMENTS 2019 CALIFORNIA EXISTING BUILDING o 1
<br /> ° CODE ��
<br /> PROPOSED TENANTS "SMALLCAKES" BAKERY STORE, °
<br /> OF THIS EXISTING VACANT COMMERCIAL SPACE,WILL HAVE A CUSTOMER ffGFCHAPTER 1: SCOPE AND ADMINISTRATION Z
<br /> SERVING COUNTER,A BAKERY STATION,AN ENCLOSED KITCHEN CLEANING U D DIVISION I-CALIFORNIA ADMINISTRATION I '
<br /> AREA AND A UNISEX ALL-GENDER BATHROOM. THE PREVIOUS BUILT SPACE
<br /> HAS NO IMPROVEMENTS FROM THE PREVIOUS OCCUPANTS (APNA PUNJAB). ❑ �]
<br /> 1.1.3.1 NON STATE-REGULATED BUILDINGS, STRUCTURES AND
<br /> EXISTING EXISTING OUTLET APPLICATIONS. `
<br /> CLIENT WILL PROVIDE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH w
<br /> RESTROOM 52.5 ftz - ON CEILING 10'-0" D EXCEPT AS MODIFIED BY LOCAL ORDINANCE PURSUANT TO SECTION 1.1.8, r 1 Y
<br /> EPARTMENT A PLAN REVIEW APPROVAL LETTER. � ( ) ( )
<br /> 05/18/21 LAID- 1ST COMMENT CEILING HEIGHT= 10'-0" 1O THE FOLLOWING STANDARDS IN THE CALIFORNIA CODE OF REGULATIONS, i c
<br /> THIS SITE HAS A FRONTAGE ROAD(HARLAN RD)ON THE NORTH SIDE OF THE 3'-0"INTERIO `\ TITLE 24,PARTS 2,2.5, 3,4, 5, 6,9, 10 AND 11 SHALL APPLY TO ALL .
<br /> PROPERTY. L DOOR
<br /> OCCUPANCIES AND APPLICATIONS NOT REGULATED BY A STATE AGENCY. *
<br /> � �
<br /> THE CITY OF LATHROP STORM ACCESS IS NORTH OF THE PROPERTY,WEST OF DIVISION II
<br /> THE INTERSTATE 5 ON-RAMP. EXISTING TAN TILE
<br /> LEXISTING TO BE REMOVED ALONG ° D SCOPE AND ADMINISTRATION C.0#0 ELECT.PANEL V J a
<br /> THE CITY OF LATHROP SEWER ACCESS ON HARLAN RD. WITH VINYL LINOLIUM
<br /> THE CAL WATER IS AT HARLAN RD. (TYP) SECTION 106-CONSTRUCTION DOCUMENTS 0
<br /> EXISTING OUTLET a o
<br /> `O ON CEILING(10'-0") �'
<br /> °O PREVIOUS TENANT M 106.1 GENERAL. 1 � & V ? ,
<br /> THE PG&E GAS UTILITY IS AT HARLAN RD. REMOVED MOP SINK. SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS, � '- Cr
<br /> \\ DRAIN REMAINS SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS, z�
<br /> YOU MUST CALL CITY OF LATHROP,CAL WATER,AND PG&E FOR �` INVESTIGATION AND EVALUATION REPORTS,AND OTHER DATA SHALL BE t ^ i 0 p ,x H zi _V
<br /> PROPOSED TIE-INS/STUB-UPS TO THESE BUILT UTILITIES. O V SUBMITTED IN TWO OR MORE SETS WITH EACH APPLICATION FOR A PERMIT. `'+ P" ¢ w �!' Cn
<br /> A EXISTING GREY TILE EXISTING BUILDING �C d EXCEPTION: THE CODE OFFICIAL IS AUTHORIZED TO WAIVE THE W
<br /> UTILITY NOTES: H PROPOSED BAKERY FLOOR CEILING HEIGHT= 10'-0" y O 0
<br /> W TO BE COVERED OVER SUBMISSION OF CONSTRUCTION DOCUMENTS AND OTHER DATA NOT
<br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY C (TYP) (1,823 sq.ft.) o REQUIRED TO BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL Z
<br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE W IF IT IS FOUND THAT THE NATURE OF THE WORK APPLIED FOR IS SUCH
<br /> THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE ``' ° THAT REVIEWING OF CONSTRUCTION DOCUMENTS IS NOT NECESSARY Z
<br /> AREA,EITHER IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT W TO OBTAIN COMPLIANCE WITH THIS CODE.
<br /> GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT ,
<br /> LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS vel
<br /> ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE.THE SURVEYOR HAS 106.2 CONSTRUCTION DOCUMENTS. e o
<br /> NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. W 7 D CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE WITH SECTIONSh
<br /> EXISTING OUTLET 106.2.1 THROUGH 106.2.5. a
<br /> BUILDING CODE ANALYSIS: EXISTING 4"x4" STEEL POLE ON CEILING(10'-0") °
<br /> FROM FLOOR THRU CEILING M ° 106.2.1 CONSTRUCTION DOCUMENTS. 0
<br /> Q 05/18/21 LBID -1 C1
<br /> CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON N y
<br /> OCCUPANCY GROUP: GROUP B-1 (CBC 304.1) 2ND COMMENT
<br /> T SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO a au .
<br /> TYPE OF CONSTRUCTION: SB EXISTING) 0 05/18/21 LBID 3RD COMMEN T BE SUBMITTED WHERE APPROVED BY THE CODE OFFICIAL. CONSTRUCTION
<br /> FIRE SPRINKLERS: YES
<br /> STORIES: 1 - EXISTING GREY TILE DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE e N a
<br /> ° TO BE COVERED OVER "' LOCATION,NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW [
<br /> BUILDING HEIGHT: 10-0 -M
<br /> ALLOWABLE FLOOR AREA: 1,920ftz w (TYP) p IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE o.
<br /> ° AND RELEVANT LAWS,ORDINANCES,RULES AND REGULATIONS,AS
<br /> FLOOR AREA: 1,920ftz DETERMINED BY THE CODE OFFICIAL. THE WORK AREAS SHALL BE
<br /> A05/18/21 LBID 4TH COMMENT
<br /> N SHOWN.
<br /> OCCUPANCY LOAD PER(CBC 1004-TABLE 1004.5) PERSONS SECTION 109-INSPECTIONS v� T� ^ w M
<br /> ACCESSORY STORAGE AREAS 15O v� V1 /�/ O
<br /> BUSINESS AREAS 6 Q kn
<br /> ASSEMBLY WITHOUT FIXED SEATS (STANDING SPACES) 42 T BUILDING SP 109.3.6 FIRE AND SMOKE-RESISTANT PENETRATIONS. w � Q�
<br /> PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTANCE-RATED Q O Q
<br /> KITCHEN,COMMERCIAL 3 ASSEMBLIES, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL NOT
<br /> TOTAL OCCUPANCY LOAD 52 EXISING FLOOR PLAN "C
<br /> 1 05/13/21 LFD- 1 ST REVIEW V1 Q C N
<br /> 05/18/21 LBID 4TH COMMENT SCALE: 1/4"= F-0" NOTE:
<br /> 19 CALIFORNIA BUILDING CODE EXISTING VACANT BUILDING SPACE HAS EXISTING FIRE ALARM.
<br /> PROPOSED BAKERY STORE MUST GET NEW FIRE ALARM SERVICE. Q'
<br /> CHAPTER 10-MEANS OF EGRESS Q x U O
<br /> SECTION 1004-OCCUPANT LOAD W q
<br /> 1004.1 DESIGN OCCUPANT LOAD. IN DETERMINING MEANS OF EGRESS O
<br /> REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM MEANS OF EGRESS
<br /> FACILITIES ARE PROVIDED SHALL BE DETERMINED IN ACCORDANCE WITH Q Q�
<br /> THIS SECTION AND TABLE 1004.5
<br /> (MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT).
<br /> Q O
<br /> LEGEND
<br /> EXIT ILLUMINATED EXIT SIGN O '�
<br /> H O
<br /> SECURITY LIGHTS
<br /> FIRE ALARM
<br /> ❑ EXHAUST FAN W/LIGHT
<br /> UNAUTHORIZED CHANGES&USES:
<br /> The design firm preparing these plans will not be responsible for,or liable for,
<br /> DUPLEX AC OUTLET 120V unauthorized changes to or uses of these plans.All changes to these plans MUST be in
<br /> PERMIT NOTE: writing and must be approved by the preparer of these plans.
<br /> The issuance of a permit or approval of plans or specifications shall not be deemed or CHECKED BY: J.AGUIRRE (E.O.R.)
<br /> construed to be a permit for an approval of any violation of any of the provisions of the LIGHT SWITCH G.MENDOZA
<br /> California state building codes or local ordinances. CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS
<br /> Construction contractor agrees that in accordance with generally acepted construction G.MENDOZA
<br /> practices,construction contractor will be required to assume sole and complete GNS
<br /> DUPLEX AC OUTLET 120V P � lete DRAWN BY: PHANTOM DESI
<br /> q p
<br /> (ON CEILING) Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1/4"= F-0"
<br /> DESIGN NOTE: including safety of all persons and property;that this requirement shall be made to apply
<br /> Electronic versions of the line work on this plan may not be consistent with other continuously and not to be limited to normal working hours, and construction contractor DATE: 04/30/2021
<br /> dimensions,notes,details,or descriptions which control the intent design. electronic B SECURITY SENSOR 4' 0 2' 4' further agrees to defend,imdemnify and hold design professional harmless from any
<br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this
<br /> improvements in the field. project, except liability arising from the sole negligence of the design professional.
<br /> SCALE: 1/4"= 1'-0" x2 ,. O
<br />
|