Laserfiche WebLink
FIRE ALARM SYMBOL LEGEND (SOME MAY NOT BE USED) ELECTRICAL SYMBOL LEGEND (SOME MAY NOT BE USED) <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> FACP FIRE ALARM CONTROL PANEL Imo' FIRE ALARM BELL $ WALL MOUNTED SINGLE RECEPTACLE, NEMA 5-20R ® PANELBOARD, LIGHTING AND APPLIANCE <br /> EVAC FIRE ALARM VOICE EVACUATION PANEL OCI FIRE ALARM HORN, WALL MOUNTED WALL MOUNTED DUPLEX RECEPTACLE ® POWER DISTRIBUTION PANEL OR SWITCHBOARD <br /> FAA FIRE ALARM REMOTE ANNUNCIATOR 04 FIRE ALARM SPEAKER, WALL MOUNTED WALL MOUNTED DEDICATED DUPLEX RECEPTACLE g METER AND SOCKET <br /> NAC FIRE ALARM NOTIFICATION APPLIANCE POWER SUPPLY ® FIRE ALARM STROBE, WALL MOUNTED SWITCHED OR OR SPDUPLEX <br /> IT W RRECEPTACLE, ONE RECEPTACLE WALL MOUNTED JUNCTION/OUTLET BOX <br /> DFATC FIRE ALARM TERMINAL CABINET FIRE ALARM COMBINATION HORN WALL MOUNTED QUADRUPLEX RECEPTACLE FLUSH FLOOR MOUNTED JUNCTION/OUTLET BOX <br /> M1 AND STROBE, WALL MOUNTED <br /> TPR O FIRE ALARM TRANSPONDER FIRE ALARM COMBINATION SPEAKER WALL MOUNTED DEDICATED QUADRUPLEX RECEPTACLE CEILING MOUNTED JUNCTION/OUTLET BOX AND STROBE, WALL MOUNTED C <br /> CO 2020 STARBUCKS COFFEE COMPANY <br /> FT FIRE ALARM CODED TRANSMITTER OCIC FIRE ALARM HORN, CEILING MOUNTED =0 WALL MOUNTED QUADRUPLEX RECEPTACLE, SPLIT—WIRED ( JUNCTION BOX MOUNTED ABOVE CEILING O <br /> WALL MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION R <br /> DK FIRE ALARM DRILL KEY SWITCH 04C FIRE ALARM SPEAKER, CEILING MOUNTED AS NOTED MULTI—OUTLET ASSEMBLY S I ARBUCKS <br /> FIRE ALARM MANUAL PULLSTATION ®C FIRE ALARM STROBE, CEILING MOUNTED INDICATED MOUNTED <br /> TED01-HERWISEE RECEPTACLE, NEMA 14-50R UNLESS 1 CORD AND PLUG 2401 UTAH AVENUE SOUTH <br /> � FIRE ALARM COMBINATION HORN SEATTLE, WASHINGTON 98134 <br /> AUTOMATIC SMOKE DETECTOR, WALL MOUNTED IMNC AND STROBE, CEILING MOUNTED Q FLUSH FLOOR MOUNTED SINGLE RECEPTACLE, NEMA 5-20R MOTOR (206) 318-1575 <br /> � FIRE ALARM COMBINATION SPEAKER FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE <br /> AUTOMATIC SMOKE DETECTOR, CEILING MOUNTED IxI�C AND STROBE, CEILING MOUNTED ® XXAX SAFETY SWITCH, SIZE AS INDICATED ON PLAN THESE DRAWINGS AND THE PROJECT MANUAL <br /> ® FLUSH FLOOR MOUNTED DEDICATED DUPLEX RECEPTACLE ARE CONFIDENTIAL AND SHALL REMAIN THE AUTOMATIC SMOKE DETECTOR, DUCT MOUNTED, AND FIRE ALARM MINIATURE HORN FUSES <br /> D FIRE ALARM RELAY (INTEGRAL OR FIELD INSTALLED) � AND STROBE, WALL MOUNTED ® <br /> FIRE ALARM MINIATURE HORN SOLE PROPERTY OF STARBUCKS <br /> � <br /> RTS DUCT SMOKE DETECTOR REMOTE TEST SWITCH P>c AND STROBE, CEILING MOUNTED ® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE, SPLIT—WIRED XX COMBINATION CORPORATION,WHICH IS THE OWNER OF THE <br /> AUTOMATIC HEAT DETECTOR, WALL MOUNTED CZAM FIRE ALARM CONTROL ZONE ADDRESSABLE MODULE FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE FUSES <br /> DIISCONNECOTNSWITCH, SIZE OAS INTOR DICATED ON PLAN COPYRIGHT IN THIS WORK. THEY SHALL NOT BE <br /> O ® REPRODUCED(IN WHOLE OR IN PART), SHARED <br /> AUTOMATIC HEAT DETECTOR, CEILING MOUNTED MZAM FIRE ALARM MONITOR ZONE ADDRESSABLE MODULE ® MOD FLUSH FLOOR MOUNTED DEDICATED QUADRUPLEX RECEPTACLE SWITCH. SPST UNLESS INDICATED WITH MODIFIER. HORSEPOWER WITH THIRD PARTIES OR USED IN ANY MANNER <br /> RATED WHEN USED FOR MOTOR CONTROL OR DISCONNECTING ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> AUTOMATIC SMOKE DETECTOR BEAM FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE MEANS. PROJECT WITHOUT THE PRIOR WRITTEN <br /> _TBT TRANSMITTER, WALL MOUNTED IAM FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE ® SPLIT-WIRED <br /> SWITCH MODIFIERS. INCLUDING M INATT N THEREOF: CONSENT OF STARBUCKS CORPORATION. <br /> TBT AUTOM IIITESMOKED DETECTOR <br /> BEAM ZAM FIRE ALARM ZONE ADDRESSABLE MODULE ® FLUSH FLOOR MOUNTED SPECIAL RECEPTACLE, THESE DRAWINGS AND SPECIFICATIONS ARE <br /> NEMA CONFIGURATION AS NOTED 3: 3-WAY (SPDT). <br /> AUTOMATIC SMOKE DETECTOR ABOVE FLOOR SERVICE FITTING, HUBBELL #SC3098A OR 4: 4-WAY. INTENDED TO EXPRESS DESIGN INTENT FORA <br /> _TBR BEAM RECEIVER, WALL MOUNTED MM FIRE ALARM MONITOR MODULE ® EQUAL; NEMA CONFIGURATION AS NOTED D: DIMMER. PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> F: BOX COVER UNIT, BUSSMANN SSU SERIES. <br /> AUTOMATIC SMOKE DETECTOR, CM FIRE ALARM CONTROL MODULE CEILING MOUNTED SINGLE RECEPTACLE, NEMA 5-20R G: GLOW HANDLE (.HANDLE GLOWS WHEN SWITCH IS OFF). SUBJECT TO CHANGE AT ANYTIME)AND DO NOT <br /> TBR BEAM RECEIVER, CEILING MOUNTED ❑ MC/DC C=FLUSH CEILING, DC=DROPCORD H: HORIZONTALLY MOUNTED. REFLECT ACTUAL SITE CONDITIONS. NEITHER <br /> �C=FLUSH <br /> ILING MOUNTED DUPLEX RECEPT CLE K: KEY OPERATED. PARTY SHALL HAVE ANY OBLIGATION NOR <br /> AUTOMATIC SMOKE ALARM, WALL MOUNTED EOL END OF LINE RESISTORDC=DROPCORD M: MANUAL MOTOR CONTROLLER WITH OVERLOAD HEATER. <br /> �SA O ®C/DC CEILING, SB: SWITCH BANK (GANGED SWITCHES) LIABILITY TO THE OTHER(EXCEPT STATED <br /> CEILING MOUNTED DEDICATED DUPLEX RECEPTACLE OS1: OCCUPANCY SENSOR. <br /> TSA AUTOMATIC SMOKE ALARM, CEILING MOUNTED §_0F FIRE SPRINKLER FLOW SWITCH ®C/DC (C-FLUSH CEILING, DC=DROPCORD) OS2: DUAL-RELAY OCCUPANCY SENSOR. ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY <br /> FIRE SPRINKLER TAMPER SWITCH AND CORROSION CEILING MOUNTED DUPLEX RECEPTACLE, SPLIT-WIRED P: PILOT LIGHT (PILOT ON WHEN SWITCH IS ON). EXECUTED BY BOTH PARTIES. <br /> _DUV FLAME DETECTOR, ULTRAVIOLET TYPEF MONITORING SYSTEM SUPERVISORY CONNECTION ®C/DC C=FLUSH CEILING, DC=DROPCORD T: TIMER. <br /> LV: LOW VOLTAGE. STARBUCKS TEMPLATE VERSION: 12020-01-31.1 <br /> PIV FIRE SPRINKLER ELECTRONICALLY CEILING MOUNTED QUADRUPLEX RECEPTACLE OR: OVERRIDE. <br /> FLAME DETECTOR, INFRARED TYPE <br /> _0IR O SUPERVISED POST INDICATOR VALVE ®C/DC (C=FLUSH CEILING, DC=DROPCORD) OT: OVERRIDE WITH TIMER. <br /> (� CEILING MOUNTED DEDICATED QUADRUPLEX RECEPTACLE WP: WEATHERPROOF <br /> _0VR FLAME DETECTOR, VISIBLE RADIATION TYPE I FIRE ALARM MAGNETIC DOOR HOLDER ®C/DC (C=FLUSH CEILING, DC=DROPCORD) DTC: SPDT CENTER OFF MAINTAINED CONTACT. ARCHITECT OF RECORD <br /> CEILING MOUNTED QUADRUPLEX RECEPTACLE, SPLIT—WIRED LOWERCASE'LEECENTER OCFON�TROM LUMINAIRE WITH SAME LETTER. CD CO > <br /> HESS HOOD FIRE SUPPRESSION SYSTEM FIRE FIGHTER'S PHONE ®C/DC (C=FLUSH CEILING, DC=DROPCORD) � o z <br /> HOOD FIRE SUPPRESSION SYSTEM MANUAL PULLSTATION '�' FIRE ALARM KEY REPOSITORY KNOX BOX CEILING MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION S CEILING MOUNTED PHOTOSENSOR UZ C) <br /> mm ( ) ®C/DC AS NOTED (C=FLUSH CEILING, DC=DROPCORD) <br /> EX EXISTING FIRE ALARM SYSTEM COMPONENT ® FIRE ALARM RELAY �� BRANCH CIRCUITING, CONCEALED IN WALL OR CEILING CEILING MOUNTED MOTION SENSOR <br /> cn <br /> RR RELOCATED AND REUSED FIRE ALARM SYSTEM COMPONENT FIRE ALARM SYSTEM JUNCTION BOX BRANCH CIRCUITING, CONCEALED IN OR UNDER FLOOR OS CEILING MOUNTED OCCUPANCY SENSOR <br /> rE] FUSE DISCONNECT SWITCH HVAC UNIT MOTOR SHUTDOWN BRANCH CIRCUITING, EXPOSED SOS WALL MOUNTED OCCUPANCY SENSOR 4mcagPitecure <br /> 15635 Alton Parkway,Suite 100, Irvine,CA 92618 <br /> HOMERUN TO PANEL. THE NUMBER OF ARROWS INDICATES THE El AUTOMATIC TIMECLOCK P:949.553.1117 F:949.474.7056 <br /> NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE; <br /> SLASHES INDICATE NUMBER OF WIRES. GROUND WIRE IS PC PHOTOCELL ARCHITECT STAMP <br /> REQUIRED BUT NOT INDICATED. A 7 INDICATES ISOLATED R CK LIGHTING LIVE END FEED <br /> GROUND CONDUCTOR. XX® TRACK <br /> INDICATES CURRENT LIMITER RATING IF APPLICABLE v_ <br /> Q•Q�JG <br /> CONDUIT STUB XXX RPS �OWVOLGLIGHTIGWSUPPLY/TRANSFORMER; <br /> , WATTAGE RATING <br /> VERTICAL CONDUIT/CIRCUIT ALCR UL 924 AUTOMATIC LOAD CONTROL RELAY- <br /> D HUBBELL CONTROL SYSTEMS #ALCR1277 6� EQUAL ��G <br /> UL 1008 BRANCH CIRCUIT EMERGENCY LIGHTING <br /> NOTESE. <br /> GTD TRANSFER SWITCH; BODINE #GTD20A OR EQUALTELEPHONE SYSTEM SECURITY SYSTEM P DATA LINEN TE .■ BELL NOTES: EV BUZZERmmFLOOR MOUNTED TELEPHONE OUTLET; Q�0 <br /> P DENOTES NUMBER OF TELEPHONE PORTS <br /> CEILING MOUNTED TELEPHONE OUTLET; 11-19-21 <br /> q GENERAL CONTRACTOR SHALL CONTACT STARBUCKS GLOBAL NETWORK A STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY & OA DATA CABLING REFERENCED IN THIS SECTION IS SEPARATE FROM THE CHIME IC *P DENOTES NUMBER OF TELEPHONE PORTS <br /> O OPERATIONS CENTER (GNOC) PRIOR TO BEGINNING CONSTRUCTION TO ORDER O TELEPHONE AND T-1 CIRCUITS S SPEAKER, CEILING - WALL MOUNTED TELEPHONE OUTLET- <br /> OPERATIONS THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION O P DENOTES NUMBER OF TELEPHONE PORTS <br /> TELEPHONE LINES. OF SECURITY SYSTEM FOR TWO TIMES, ROUGH-IN PRIOR TO DRYWALL g STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO �S SPEAKER, WALL ® FLOOR MOUNTED DATA OUTLET; <br /> INSTALLATION AND FINAL TRIM PRIOR TO STORE TURNOVER, SECURITY VENDOR O D DENOTES NUMBER OF DATA PORTS <br /> © REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY TO STARBUCKS REQUIRES A MINIMUM TWO WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY SUPPLY AND INSTALL CATEGORY 5 LAN CABLE AND CONNECTORS FOR THE ® CEILING MOUNTED DATA OUTLET; <br /> GLOBAL NETWORK OPERATIONS CENTER (GNOC) VIA EMAIL GNOC@STARBUCKS.COM. VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES <br /> POS SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING s G SPEAKER, GROUND-MOUNTED C *D DENOTES NUMBER OF DATA PORTS <br /> INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY W/ DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME vC VOLUME CONTROL 0 WALL MOUNTED DATA OUTLET; <br /> OC CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT LANDLORD HAS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL *D DENOTES NUMBER OF DATA PORTS <br /> 1" INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S AMP SOUND SYSTEM AMPLIFIER FLOOR MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; <br /> FURNISHED AND INSTALLED (1) 12 CONDUIT INCLUDING PULL STRING FROM D ® P D DENOTES NUMBER OF TELEPHONE DATA PORTS <br /> THE TELEPHONE POINT OF PRESENCE TO THE STARBUCKS WORKROOM. NOTIFY SECURITY VENDOR FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CEILING MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; <br /> STARBUCKS CONSTRUCTION MANAGER (SEE SHEET G1.0) CONTRACTOR. ® LOW VOLTAGE CONTROL TRANSFORMER ®C *P *D DENOTES NUMBER OF TELEPHONE DATA PORTS <br /> IMMEDIATELY IF CONDUIT AND PULL STRING ARE NOT INSTALLED. THE DIEBOLD COMPANY R RELAY v WALL MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; <br /> CONTACT: STARBUCKS PROJECT MANAGEMENT TEAM © AT THE START OF CONSTRUCTION, STARBUCKS CM SCHEDULES DELIVERY OF P „D DENOTES NUMBER OF TELEPHONE DATA PORTS L <br /> PHONE: 206 318 6688 3 4 THICK PLYWOOD BACKBOARD <br /> �D ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY ❑ PUSHBUTTON STATION, ONE BUTTON m <br /> TELEPHONE/NETWORK CABLING VENOR AND THE SECURITY SYSTEM VENDOR. <br /> EMAIL: DOCC.STARBUCKS@DIEBOLD.COM A DATA CABLING TECHNICIAN FOR TWO DAYS PRIOR TO CONSTRUCTION END. S ZE AS INDICATED ON DRAWINGS O O <br /> TELEPHONE/NETWORK CABLING VENDOR SHALL BE SCHEDULED SUCH THAT CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO WEEKS PRIOR TO DELIVERY •• PUSHBUTTON STATION, Two BUTTON Tv FLOOR MOUNTED TELEVISION OUTLET <br /> O <br /> CABLING IS COMPLETE PRIOR TO ARRIVAL OF SECURITY SYSTEM VENDOR. AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE, ... PUSHBUTTON STATION, THREE BUTTON TV CEILING MOUNTED TELEVISION OUTLET <br /> CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY, DO NOT REFUSE DELIVERY. � C: � <br /> �E GENERAL CONTRACTOR SHALL SCHEDULE ON-SITE WORK PERFORMED BY THE NOTESE- @ DATA CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LAN CABLING AND WALL MOUNTED TELEVISION OUTLET '— .S N <br /> TELEPHONE/NETWORK CABLING VENDOR AND THE SECURITY SYSTEM VENDOR. <br /> THE TELEPHONE/NETWORK CABLING VENDOR SHALL BE SCHEDULED SUCH CONNECTIONS TO ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, AND E Lo <br /> THAT CABLING IS COMPLETE PRIOR TO ARRIVAL OF THE SECURITY A STARBUCKS CONTRACTS DIRECTLY WITH THE LANDLORD TO PROVIDE FOUR (4) MANAGER'S WORKSTATION. ,� U)) ,� <br /> ABBREVIATIONS AND MODIFIERS (SOME MAY NOT BE USED W SYSTEM VENDOR. CAT5 (WHITE) COMMUNICATION CABLES TO THE SPACE. ) uj � � � <br /> FOUR (4) CAT5 CABLES ARE DEDICATED TO STORE OPERATIONS/ @ DATA CABLING TECHNICIAN TO REMOVE PACKAGING, INSTALL AND TEST CASH AFF ABOVE FINISHED FLOOR SPST SINGLE POLE, SINGLE THROW WP WEATHERPROOF MODIFIER U <br /> COMMUNICATIONS. REGISTERS, CASH DRAWERS AND MANAGERS WORKSTATION. .. <br /> AFG ABOVE FINISHED GRADE DPST DOUBLE POLE, SINGLE THROW PT POKE—THROUGH MODIFIER Z M Q <br /> T-MOBILE T NOTES: NIC NOT IN CONTRACT 3PST THREE POLE SINGLE THROW H HORIZONTAL MOUNT MODIFIER STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING UNO UNLESS NOTED OTHERWISE 4PST FOUR POLE, SINGLE THROW HG HOSPITAL GRADE MODIFIER U U STARBUCKS POS SYSTEM DELIVERY AND INSTALLATION WITH THE DATA N.F. NON—FUSED SPDT SINGLE POLE, DOUBLE THROW IG ISOLATED GROUND MODIFIER06 <br /> MUSIC SYSTEM NOTES: CABLING VENDOR. THIS GROUP MAY BE CONTACTED AT: GFPE GROUND—FAULT PROTECTION OF EQUIPMENT DPDT DOUBLE POLE, DOUBLE THROW TR TAMPER—RESISTANT MODIFIER � � U <br /> NEWSTORE@STARBUCKS.COM ERMS ARC ENERGY REDUCING MAINTENANCE SWITCH3PDT THREE POLE DOUBLE THROW SP SURGE PROTECTION MODIFIER Q LO Q O <br /> ALL CABLING AND INFRASTRUCTURE TO SUPPORT THE T-MOBILE T-1 HOTSPOT ST SHUNT TRIP MODIFIER 4PDT FOUR POLE, DOUBLE THROW GFCI GROUND—FAULT CIRCUIT INTERRUPTER O 4"' <br /> OR WI-FI NETWORK SHALL BE FURNISHED AND INSTALLED BY T-MOBILE. GND GROUND EM EMERGENCY LIGHT MODIFIER MODIFIER - M W <br /> OA PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. EGC EQUIPMENT GROUNDING CONDUCTOR NL NIGHTLIGHT LUMINAIRE MODIFIER SR SHOW WINDOW RECEPTACLE MOUNTED WITHIN <br /> OA THE T-MOBILE T-1 CIRCUIT WILL BE ORDERED BY T-MOBILE AND COORDINATED CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. MOUNT GEC GROUNDING ELECTRODE CONDUCTOR +XX" MOUNTING HEIGHT MODIFIER 18 INCHES OF TOP OF SHOW WINDOW STORE #: 20685 <br /> THROUGH STARBUCKS HOTSPOT DEPLOYMENT TEAM. NOT ALL STORES WILL OWNER FURNISHED SPEAKERS WHERE SHOWN AND IN COORDINATION WITH AHJ AUTHORITY HAVING JURISDICTION CR CONTROLLED RECEPTACLE MODIFIER <br /> CH CLOCK HANGER RECEPTACLE <br /> HAVE THIS CIRCUIT INSTALLED AT THE NEW STORE OPENING DATE, BUT A ARCHITECTURAL PLANS AND DETAILS. FOLLOW MANUFACTURERS INSTALLATION NEC NATIONAL ELECTRICAL CODE (NFPA 70) use DEVICE WITH USB PORT(S) MODIFIER PROJECT#: 59335-039 <br /> CABLE EXTENSION FOR THIS CIRCUIT WILL BE PROVIDED BY STARBUCKS REQUIREMENTS. ISSUE DATE: CHECKSET <br /> TELEPHONE/NETWORK CABLING VENDOR AT THE SAME TIME AS THE <br /> TELEPHONE/NETWORK EXTENSIONS FOR FUTURE USE. DESIGN MANAGER: J.RAMOS <br /> PRODUCTION DESIGNER: <br /> CHECKED BY: GRS <br /> MCG PROJECT#: 21324 <br /> MCG PROJ. MANAGER: J.SPENCER <br /> MCG PROJ. SPECIALIST: <br /> Revision Schedule <br /> Rev Date By Description <br /> SHEET TITLE: <br /> ELECTRICAL NOTES, <br /> DETAILS, LEGENDS <br /> SCALE:AS SHOWN <br /> SHEET NUMBER: <br /> E-0004 <br />