My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3011
>
1600 - Food Program
>
PR0538752
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 1:37:02 PM
Creation date
1/11/2022 10:14:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0538752
PE
1624
FACILITY_ID
FA0022252
FACILITY_NAME
STARBUCKS COFFEE #20685
STREET_NUMBER
3011
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
10018010
CURRENT_STATUS
01
SITE_LOCATION
3011 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL GENERAL NOTES ., <br /> A. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON <br /> INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. <br /> THE CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO .. <br /> ADDITIONAL EXPENSE TO THE OWNER. <br /> B. THE CONTRACTOR SHALL VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS <br /> AGAINST THE CONTRACT DOCUMENTS,AND FAMILIARIZE HIMSELF WITH THE WORK <br /> PRIOR TO BIDDING AND START OF THE WORK. BY SIGNING THE CONTRACT,THE <br /> CONTRACTOR ACKNOWLEDGES THE SITE VISIT HAS BEEN COMPLETED AND THE <br /> EXISTING CONDITIONS ARE ACCEPTED. <br /> C. THE CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING EQUIPMENT, 0 <br /> DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC.THAT ARE NOT <br /> SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW (9)2020 STARBUCKS COFFEE COMPANY <br /> WORK. S I ARBUCKS <br /> O <br /> D. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR <br /> ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED 2401 UTAH AVENUE SOUTH <br /> TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR SEATTLE, WASHINGTON 98134 <br /> BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR <br /> EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED (206) 318-1575 <br /> SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2"INTO THE WALL <br /> OR FLOOR AND THE OPENING GROUTED SMOOTH. THESE DRAWINGS AND THE PROJECT MANUAL <br /> E. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> TO REMAINING EQUIPMENT, DEVICES,AND LUMINAIRES THAT ARE NOT BEING SOLE PROPERTY OF STARBUCKS <br /> REMOVED. CORPORATION,WHICH IS THE OWNER OF THE <br /> COPYRIGHT IN THIS WORK. THEY SHALL NOT BE <br /> F. ANY EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION THROUGHOUT REPRODUCED(IN WHOLE OR IN PART), SHARED <br /> CONSTRUCTION.AUTOMATIC SMOKE DETECTORS IN THE AREA OF CONSTRUCTION WITH THIRD PARTIES OR USED IN ANY MANNER <br /> SHALL BE DISCONNECTED AND TEMPORARILT REPLACED WITH HEAT DETECTORS WHEN ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> THE SPACE IS STAFFED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROVED PROJECT WITHOUT THE PRIOR WRITTEN <br /> FIRE SAFETY PROCEDURES OF THE OWNER AND THE LOCAL FIRE MARSHALL, BUT CONSENT OF STARBUCKS CORPORATION. <br /> SHALL BE REACTIVATED WHENEVER THE SPACE IS NOT OCCUPIED BY THE THESE DRAWINGS AND SPECIFICATIONS ARE <br /> CONTRACTOR.AUTOMATIC SMOKE DETECTORS SHALL BE PROTECTED FROM DUST AND <br /> DIRT ACCUMULATION BY REMOVING THE DEVICE FROM ITS BASE DURING THOSE INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> TIMES WHEN THE SYSTEM IS ALLOWED TO BE OUT OF OPERATION. PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> G. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING SUBJECT TO CHANGE AT ANYTIME)AND DO NOT <br /> DESIGN,ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN REFLECT ACTUAL SITE CONDITIONS. NEITHER <br /> CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 PARTY SHALL HAVE ANY OBLIGATION NOR <br /> AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATE PLENUM LIABILITY TO THE OTHER(EXCEPT STATED <br /> CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. LUMINAIRES THAT ARE ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY <br /> MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND ARE NOT EXECUTED BY BOTH PARTIES. <br /> REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. <br /> COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN ANY MILLWORK STARBUCKS TEMPLATE VERSION: i2020-01-31.1 <br /> WITH MILLWORK VENDOR PRIOR TO ROUGH-IN. <br /> H. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITH ANY MILLWORK ARCHITECT OF RECORD <br /> WITH MILLWORK VENDOR PRIOR TO ROUGH-IN. �0; <br />
The URL can be used to link to this page
Your browser does not support the video tag.