Laserfiche WebLink
? au *:O.i SAN J O A Q U I N Environmental Health Department <br /> pP..... ......... C <br /> J: <br /> Q i� <br /> COUNTY Jasjit Kang , REHS , Director <br /> cq iF0... Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> April 20 , 2022 Michelle Henry , REHS <br /> Merlin Bowen <br /> Gettler- Ryan , Inc . <br /> 6805 Sierra Court , Suite G <br /> Dublin , CA 94568 <br /> Re : ARCO 02093 SR0085128 <br /> 3425 Tracy Blvd , Tracy , CA 95376 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace manway lids on 91 tank and three 87 tanks <br /> • Replace spill containers on 91 tank and three 87 tanks <br /> • Replace overfill valves on 91 tank and three 87 tanks <br /> • Install tank bottom protectors on 91 tank and three 87 tanks <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust (csigov . org to arrange the following appointments (a 48 - hour <br /> notice is required for inspection appointments ) . <br /> a . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume <br /> shut off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> b . Verification that ball float(s ) , if installed , do not interfere with the installed flapper valve . <br /> c . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test <br /> ( or equivalent) . Proper drainage must also be verified . <br /> d . Since concrete will be broken near the UST , a secondary containment test must be <br /> performed on the 91 and three 87 tanks once concrete is poured in accordance with the <br /> manufacturer' s guidelines . <br /> Please be aware that the facility cannot receive fuel in the 91 and three 87 tanks prior to the <br /> EHD inspection and approval. <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468 -3420 F 209 464 -0138 1 www . sjgov . org /ehd <br />