Laserfiche WebLink
The addition of anothcr 218.5 acres to the Special Purpose plan would normally require <br /> approximately 393,300 gallons of water per day, according to water use estimates included in the <br /> San Joaquin: County Public Works Improvement Standards (1,800 gallons per day per acre of <br /> industrial use). However, the amendment of the 218.5 acres into the Special Purpose Plan is being <br /> proposed to accommodate a specific use, the ADT Auto Auction. The auto auction will consume <br /> much less water than typical industrial development of the land,since most of the land will be used <br /> for car storage. Engineers for ADT have calculated that the facility would consume approximately <br /> 57,760 gallons of water per day. <br /> The conceptual water delivery system, originally outlined in the Special Purpose Plan, would be <br /> modified to reflect the site plan for the ADT Auto Auction. The auto auction will use private water <br /> lines to serve the entire 218.5-acre site. Thus,the revised conceptual water system design would be <br /> revised so that the public water lines end at the entrance to the ADT parcel. The original alignments <br /> of the public loop road and public water lines to serve individual industrial lots would be deleted <br /> (Figure 9). <br /> Wastewater Service <br /> The terms of the services agreement between Prologis(King&Lyons)and the City of Tracy require <br /> the City to treat up to 319,000 gallons of wastewater from the business park. A permanent <br /> wastewater line was completed between the business park and the regional shopping mall at the <br /> Grant Line/1-205 interchange. Sewage is sent to the City's wastewater treatment plant adjacent to <br /> the Spreckels Sugar plant. <br /> At the time that the Special Purpose Plan was adopted in May, 1994,the City of Tracy had allocated <br /> all of the capacity of the City wastewater treatment plant to existing uses and planned growth. <br /> Prologis was able to receive a commitment from the City to treat up to 319,000 gallons per day after <br /> buying the sewage discharge rights from an industrial plant in the City which had gone out of <br /> business.The projected wastewater generation for full development of the entire 610-acre business <br /> park is expected to be between approximately 750,000 and 860,000 gallons per day (see Special <br /> Purpose Plan, page 57). The 128 acres within the 1994 Special Purpose Plan boundaries were <br /> estimated to generate 209,000 gallons per day. <br /> The amendment of 218.5 acres into the Special Purpose Plan requires the issuance of a"will serve" <br /> letter from Tracy, indicating that the City has the capacity to treat the additional amount of <br /> wastewater from the amendment area. An application to the City of Tracy requesting an amendment <br /> to the Services Agreement to the serve the additional land will be processed concurrently with the <br /> Special Purpose Plan Amendment. <br /> The addition of another 218.5 acres to the Special Purpose plan would normally require <br /> approximately 349,600 gallons of wastewater per day,according to wastewater generation estimates <br /> included in the San Joaquin County Public Works Improvement Standards (1,600 gallons per day <br /> per acre of industrial use). However, the amendment of the 218.5 acres into the Special Purpose <br /> Plan is being proposed to accommodate a specific use, the ADT Auto Auction. The auto auction <br /> will generate much less wastewater than typical industrial development of the land, since most of <br /> 93231-BO.spp00.wpd•224/00 -16- <br />