LEAK DETECTION <br /> T E C H N 0 L 0 G I E S LLC <br /> Exclusive Providers for MDleak® and PHDIeakT' Technologies <br /> 2765 East Wieding Rd Tucson, AZ 85718 Phone 520 . 207 . 4878 FAQ : 520 . 990 . 8965 • www.LeakDetect. net <br /> Procedure : <br /> 1 . A Proprietary Chemical Marker/Tracer is added to the liquid within the tank interstice during the j <br /> ELD pre-backfill pretest. <br /> 2 . Systems check : <br /> a. Prior to starting the test an evaluation of the accessible system components is completed. <br /> LDT will scan exposed components and identifying any leaks for the contractor who will <br /> make repairs . After the completion of the repairs the contractor may leave the site . <br /> b . Once all the accessible components with leaks are repair, LDT can begin testing the <br /> underground portion of the system . <br /> 3 . Testing : <br /> a. All secondary containments are sampled and analyzed for the background concentration. <br /> i . The tank interstice chemical marker concentration is analyzed and noted. <br /> ii . Pipeline secondary should be free of all chemical marker that are to be used during <br /> this phase of testing. <br /> b . A new Chemical Marker/Tracer is pumped throughout the systems primary; product, vent, <br /> vapor return piping and dry interstice tanks . <br /> c . Each component is pressurized to the working pressure of the individual component with <br /> the chemical marker. <br /> d. Once the primary component is pressurized with the Chemical Marker/Tracer gas the <br /> secondary containment surrounding the primary containment can be sampled. This <br /> sampling even includes tank sumps , pipelines , and dry tank interstice for primary tank leaks . <br /> e . If the Chemical Marker/Tracer is found in the secondary containment sample a leak is <br /> declared and the leak location will be identified . <br /> 4 . Tank Testing : <br /> a. During the day of testing the primary tank is to be maintained closed from the atmosphere <br /> b . Dry interstice tanks primaries are inoculated first <br /> i . Sampling of the tank interstice is performed for the chemical marker. <br /> c . Wet interstice tanks REQUIRE all liquids to be removed from the tank primary 72-hours <br /> before testing can begin . No liquid can be added or removed to the tank interstice during <br /> the 72-hour period. <br /> 5 . Spill Bucket Testing : <br /> a . Spill Buckets are pneumatically tested. A leak rate is calculated and could indicate a leak <br /> within the spill bucket. <br /> b . If a leak is detected the contractor will be directed to the leak and a repair of the spill bucket <br /> will be completed. <br /> I <br /> Author David Rabb 7of 8 <br /> Version 210505 <br />