Laserfiche WebLink
ENVIRONMENTAL QPIAA P0 S -t- <br />Analytical Chemists <br />October 11, 2010 <br />Tracy Material Recovery & Solid Waste Tr Lab ID <br />PO BOX 93 Customer <br />Tracy CA 95378 <br />Laboratory Report <br />STK1038457 <br />3-16455 <br />Introduction: This report package contains total of 6 pages divided into 3 sections: <br />Case Narrative (2 pages) : An overview of the work performed at FGL. <br />Sample Results (1 page) : Results for each sample submitted. <br />Quality Control (3 pages) : Supporting Quality Control (QC) results. <br />Case Narrative <br />This Case Narrative pertains to the following samples: <br />Sample Description Date ate <br />FGL Lab ID # <br />Matrix <br />Sampled ReDcei ed <br />3050 <br />The following note applies to Nickel, Chromium: <br />Compost Material 09/21/2010 09/21/2010 <br />STK1038457-001 <br />Com <br />Sampling and Receipt Information: The sample was performed by FGL using the following methods <br />(where applicable): <br />Bacteriological Sampling <br />Grab sampling for liquids <br />Composite sampling for liquids <br />Grab sampling for solids <br />Composite sampling for solids <br />- SOP:SOFS005 <br />- SOP:SOFSOIO <br />- SOP:SOFS015 <br />- SOP:SOFS020 <br />- SOP:SOFS025 <br />All samples were received, prepared and analyzed within the method specified holding times. All <br />samples arrived on ice. All samples were checked for pH if acid or base preservation is required (except <br />for VOAs). For details of sample receipt information, please see the attached Chain of Custody and <br />Condition Upon Receipt Form. <br />Quality Control: All samples were prepared and analyzed according to the following tables: <br />Inorganic - Metals QC <br />245.1 <br />09/24/2010:212062 All analysis quality controls are within established criteria. <br />09/23/2010:209951 All preparation quality controls are within established criteria, except: <br />3050 <br />The following note applies to Nickel, Chromium: <br />Office & Laboratory <br />435 Sample matrix may be affecting this analyte. Data was accepted based on the LC or CCV recovery. <br />6010B <br />09/24/2010:212045 All analysis quality controls are within established criteria. <br />Page 1 of 6 <br />Corporate Offices & Laboratory <br />Office & Laboratory <br />Office & Laboratory <br />Field Office <br />853 Corporation Street <br />2500 Stagecoach Road <br />563 E. Lindo Avenue <br />Visalia, California <br />Santa Paula, CA 93060 <br />Stockton, CA 95215 <br />Chico, CA 95926 <br />TEL: 559/734-9473 <br />TEL: 805/392-2000 <br />TEL: 209/942-0182 <br />TEL: 530/343-5818 <br />Mobile: 5591737-2399 <br />FAX 805/525-4172 <br />FAX: 209/942-0423 <br />FAX: 530/343-3807 <br />FAX: 559/734-8435 <br />CA NELAP Certification No. 01110CA <br />CA ELAP Certification No. 1563 <br />CA ELAP Certification No. 2670 <br />