Laserfiche WebLink
opnUuycG2 SAN JOAQUIN Environmental Health Department <br /> Q - <br /> N;. 1 COUNTY Jasjit Kang , REHS , Director <br /> NP <br /> < iFoa� Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> q ?� <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry , REHS <br /> June 16 , 2022 Elena Manzo , REHS <br /> James Otto <br /> LC Services <br /> 3887 N Valentine Ave <br /> Fresno , CA 93722 <br /> Re : Tracy 76 SR0085086 <br /> 2420 W Grant Line Rd , Tracy , CA 95377 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace dispensers with conversion frame installation <br /> • Replace monitoring panel <br /> • Convert contents of Tank# 10456027 - 003 from Diesel to E85 <br /> • Replace Tank# 10456027 - 003 ( new E85) : <br /> o drop tube with shut-off valve (flapper) <br /> o submersible turbine pump and leak detector <br /> o STP sump and interstitial sensor <br /> o in -tank probe , caps and adaptors <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust ( sigov . org to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments ) . <br /> a . Sensor functionality : Functionality of the monitoring system must be verified to ensure <br /> that monitoring has been restored to meet the requirements of Title 23 California Code <br /> of Regulations and the Health & Safety Code . A copy of the alarm history shall be <br /> printed prior to the replacing of the monitoring panel , and made available at the time of <br /> EHD inspection . <br /> b . Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs ) . Any potential leaks from piping and fuel filters must drain directly into <br /> UDCs . <br /> c . Visual inspection of the piping within the dispensers <br /> d . Leak detector test : leak detector must be tested to confirm that the device can detect a <br /> leak of 3 -gallons per hour at 10 psi . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www . sjgov . org /ehd <br />