COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 9:17:45 AM
Creation date
3/28/2022 12:39:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Received <br />4/8/2022 <br />From: Mike P. Barber <mbarber@sunwestengineering.com> <br />Sent: Friday, April 8, 2022 12:50 PM <br />To: Alaniz, John [EHD] <jalanizl@sjgov.org> <br />Cc: Pam Lawrence <plawrence@sunwestengineering.com>; Stephen G Wiedemann <br /><stephen.wiedemann@verizon.com>; Gritsko, Dennis <dennis.gritsko@verizon.com>; zachary.d.feingold@verizon.com; <br />Madeliene Garcia <mgarcia@sunwestengineering.com> <br />Subject: RE: [E] RE: Inspection Report HW/UST <br />Importance: High <br />CAUTION: This email is originated from outside of the organization. Do not click links or open attachments unless you recognize the <br />sender and know the content is safe. <br />Inspector Alaniz, <br />Please see responses in italicized below: <br />1. OBSERVATION: Leak detector testing was previously performed on 3/5/2020 and was completed on 6/21/2021, 3.5 <br />months past due. REGULATION GUIDANCE: These tests are required once every 12 months. CORRECTIVE ACTION: Take <br />all necessary precautions to ensure testing is performed in a timely manner. This is a Class II violation. <br />Response: Correct date for the 2021 Monitoring System Certification is 3/2/2021, not 3/5/2020. The Line leak <br />detector tester testing was performed on 6/21/2021 due to lack of calibrated line leak detector test equipment <br />availability. Subsequent line leak detector testing will coincide with the annual Monitoring System Certification <br />testing in March. <br />2. OBSERVATION: The 3/2/2021 monitoring system certification form submitted to the San Joaquin County <br />Environmental Health Department (EHD) on 4/6/2021 incorrectly stated that line leak detectors were not installed in the <br />underground storage tank system. REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days <br />of the tests. CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are <br />performed in a timely manner and are correct. Submit a corrective action statement to the EHD. This is a repeat <br />violation, Class II. <br />Response: Unchecked check box in section 7 "Check this check box if line leak detectors ARE NOT installed." <br />added note to section 9 "See August 21, 2021 leak detect testing" (see attached). <br />3. OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. A gross leak test <br />alarm occurred on 6/21/2021. The facility did not have any records showing the alarm was responded to and how it was <br />addressed. REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring <br />
The URL can be used to link to this page
Your browser does not support the video tag.