My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 9:17:45 AM
Creation date
3/28/2022 12:39:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ISO <br />9001:2015 <br />`A Before printing this message, please be sure it is necessary! <br />The information contained in this communication and any attachments is intended solely for the use of the individual or entity to whom it is addresses and others <br />authorized to receive it. It may contain confidential or legally privileged information. If you are not the intended recipient, you are hereby notified that any <br />disclosure, copying, distribution or taking any action in reliance on the contents of this information is strictly prohibited and may be unlawful. If you have received <br />this communication in error, please notify us immediately by responding to this email and then delete it from your system SunWest Engineering Constructors, Inc. <br />nor its affiliated is neither liable for the proper and complete transmission of the information contained in this communication nor for any delay in its receipt. For <br />more information on SWC, contact us at 1-888-588-8737 or visit us at www.sunwestengineering.com. <br />From: Feingold, Zachary (Zach)<zachary.d.feingold@verizon.com> <br />Sent: Friday, April 1, 2022 3:36 PM <br />To: Mike P. Barber <mbarber@sunwestengineering.com>; Madeliene Garcia<mgarcia@sunwestengineering.com> <br />Cc: Pam Lawrence <plawrence@sunwestengineering.com>; Stephen G Wiedemann <br /><stephen.wiedemann@verizon.com>; Gritsko, Dennis <dennis.gritsko@verizon.com> <br />Subject: Fwd: [E] RE: Inspection Report HW/UST <br />CAUTION: This email originated from outside of the organization. DO NOT CLICK links or open attachments unless you recognize the <br />sender and know the content is safe. <br />Mike and Madeliene, <br />Please see the attached UST inspection report. The following items were written up in the inspection report that need to <br />be addressed: <br />1. OBSERVATION: Leak detector testing was previously performed on 3/5/2020 and was completed on 6/21/2021, 3.5 <br />months past due. REGULATION GUIDANCE: These tests are required once every 12 months. CORRECTIVE ACTION: Take <br />all necessary precautions to ensure testing is performed in a timely manner. This is a Class II violation. <br />2. OBSERVATION: The 3/2/2021 monitoring system certification form submitted to the San Joaquin County <br />Environmental Health Department (EHD) on 4/6/2021 incorrectly stated that line leak detectors were not installed in the <br />underground storage tank system. REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days <br />of the tests. CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are <br />performed in a timely manner and are correct. Submit a corrective action statement to the EHD. This is a repeat <br />violation, Class II. <br />3. OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. A gross leak test <br />alarm occurred on 6/21/2021. The facility did not have any records showing the alarm was responded to and how it was <br />addressed. REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring <br />records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br />records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br />inventory readings and reconciliations. CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance <br />and monitoring records for the last three years on site and submit copies to the EHD. This is a repeat violation, Class II. <br />4. OBSERVATION: The designated operator failed to document the alarm from the attached alarm history on the <br />6/21/2021 designated operator inspection report and failed to check that it was responded to appropriately. The <br />missing alarm was a gross leak test alarm (6/21/2021). REGULATION GUIDANCE: During the inspection, the designated <br />operator shall review the alarm history since the previous inspection, check that each alarm was documented and <br />responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms <br />
The URL can be used to link to this page
Your browser does not support the video tag.