Laserfiche WebLink
SAN ,,] DAQ U I <br /> N Environmental Health Department <br /> c0uT IV <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FRANK BELLING 1 19901 S HARROLD AVE, ESCALON April 04, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 705 CFR 112.8(c)(1)Container not compatible with oil stored and/or storage conditions. <br /> OBSERVATION: Failed to use containers with material and construction compatible with material stored and <br /> conditions of storage such as pressure and temperature. One 10,000 gallon diesel tank installed inside a shed like <br /> structure was observed at the time of inspection, this tank was designed and constructed to be used as <br /> Underground Storage Tank and is not compatible with the use as Aboveground Storage Tank. <br /> REGULATION GUIDANCE: (c)(1)Not use a container for the storage of oil unless its material and construction are <br /> compatible with the material stored and conditions of storage such as pressure and temperature. <br /> CORRECTIVE ACTION: Immediately remove all oil stored in non-compatible containers. Store oil in containers <br /> with material and construction compatible with the material stored and conditions of storage such as pressure and <br /> temperature. Obtain properly constructed tank that is third-party listed for use as Aboveground Storage of <br /> Combustible or Flammable Liquids. Ensure that the SPCC plan is adequate for the facility. Submit proof of <br /> correction to the EHD. <br /> This is a Class II violation. <br /> 712 CFR 112.7(e), 112.8(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified <br /> personnel. <br /> OBSERVATION: Facility failed to ensure that tanks are inspected and tested by an appropriately qualified person in <br /> accordance with industry standards. None of the onsite tanks were tested by a qualified personnel to ensure <br /> compliance with this section. <br /> REGULATION GUIDANCE: 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular <br /> schedule and whenever you make material repairs.You must determine, in accordance with industry standards, <br /> the appropriate qualifications for personnel performing tests and inspections,the frequency and type of testing and <br /> inspections,which take into account container size, configuration, and design (such as containers that are: <br /> shop-built,field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). <br /> Examples of these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic <br /> testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing. You must keep <br /> comparison records and you must also inspect the container's supports and foundations. In addition, you must <br /> frequently inspect the outside of the container for signs of deterioration,discharges,or accumulation of oil inside <br /> diked areas. Records of inspections and tests kept under usual and customary business practices satisfy the <br /> recordkeeping requirements of this paragraph. <br /> 112.7(e) Inspections,tests, and records. Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility.You must keep these written <br /> procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector,with the <br /> SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph. <br /> CORRECTIVE ACTION: Immediately ensure that all tanks are inspected/tested by an appropriately qualified <br /> person in accordance with industry standards. Submit proof of correction/test results to the EHD. <br /> This is a Class II violation. <br /> FA0017320 PRO547601 SCO01 04/04/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 7 of 9 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />