; <br /> SAN x�JOAQU � Environmental Health Department <br /> � <br /> C0uNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FRANK BELLING 1 19901 S HARROLD AVE, ESCALON April 04, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 713 CFR 112.7(e), 112.8(c)(6) Failed to test or inspect each container for integrity based on industry standards. <br /> OBSERVATION: Facility failed to test/inspect each aboveground container for integrity based on industry <br /> standards. No SPCC plan is available that would discuss the specific testing requirements: 1. On a regular <br /> schedule. 2.After making material repairs. 3. Using non-destructive testing.4. Inspecting each container's <br /> supports,foundations, and outside for signs of deterioration, discharges, or accumulation of oil inside diked areas. <br /> REGULATION GUIDANCE: REGULATION GUIDANCE: 112.8(c)(6)Test or inspect each aboveground container <br /> for integrity on a regular schedule and whenever you make material repairs.You must determine, in accordance <br /> with industry standards,the appropriate qualifications for personnel performing tests and inspections,the frequency <br /> and type of testing and inspections,which take into account container size, configuration, and design (such as <br /> containers that are:shop-built,field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or <br /> partially buried). Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br /> testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br /> testing.You must keep comparison records and you must also inspect the container's supports and foundations. In <br /> addition, you must frequently inspect the outside of the container for signs of deterioration,discharges,or <br /> accumulation of oil inside diked areas. Records of inspections and tests kept under usual and customary business <br /> practices satisfy the recordkeeping requirements of this paragraph. <br /> 112.7(e) Inspections,tests, and records. Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility. You must keep these written <br /> procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector,with the <br /> SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph. <br /> CORRECTIVE ACTION: Immediately conduct the necessary integrity testing/inspection of all above ground <br /> containers based on industry standards,on a regular schedule, after making material repairs, using non-destructive <br /> testing, inspecting each container's supports,foundations, and outside for signs of deterioration, discharges, or <br /> accumulation of oil inside diked areas. Maintain testing and inspection records. Submit a copy of the test/ <br /> inspection results to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Conducted an Above Ground Petroleum Storage Act (APSA) inspection. A checklist was provided at the time of <br /> inspection a full report was provided (via email)on 4/14/2022. Complete and submit a copy of the Return to <br /> Compliance Certification form to the EHD with a statement documenting the corrective actions that have been or <br /> will be taken for each violation, and any supporting paperwork, by 5/14/2022. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> FA0017320 PR0547601 SCO01 04/04/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 8 of 9 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />