My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2022 2:31:59 PM
Creation date
4/25/2022 9:13:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />April 27, 2022 <br /> Facility Address: <br /> 1100 S MAIN ST, MANTECA <br /> Facility Name: <br /> MAIN STREET ARCO AM PM* <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 104 CCR 2632(d)(1), 2634(d) Failure to have an approved UST Monitoring Plan. <br />OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br />-Monitoring plan for the diesel tank incorrectly list the leak detector Manufacturer as "Fe Petro" and Model number <br />as MLD. The leak detector on site Manufacturer is "VMI" and Model number "99LD2000". <br />-Monitoring plan for the 91 tank incorrectly list the leak detector Model Number as MLD. The leak detector model <br />number is "STP MLD". <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br />System (CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br />EHD. <br />This is a minor violation. <br /> 112 CCR 2638, 2641(j), 2715(f) Failure to have properly qualified service technician test leak detection equipment every <br />12 months. <br />OBSERVATION: Annual monitoring system certification and leak detector testing were due by 03/2022 and was <br />completed on 4/27/2022, one month past due. <br />REGULATION GUIDANCE: These tests are required on March every year. <br />CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. <br />This is a repeat violation, Class II. <br /> 205 CCR 2712(i) Failure to have current UST Monitoring Plan readily accessible at the facility. <br />OBSERVATION: The accurate copy of the monitoring plans were not available for inspection. <br />REGULATION GUIDANCE: An accurate copy of these plans shall be accessible on site at all times. <br />CORRECTIVE ACTION: Immediately locate and retain a copy on site. <br />This is a minor violation. <br />FA0007464 PR0506504 SC001 04/27/2022 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 4 of 5 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.