TBTBPOCMFS <br />Point of Connection <br />Meter and backflow preventer <br />per Civil Engineer's plans, refer <br />to Civil plans for final location. <br />Mainline <br />Shown schematically. Install <br />along back of walk or curb as <br />feasible. Group valves in <br />shrub areas. <br />Master Valve and Flow Sensor <br />Master valve and flow sensor, <br />install downstream of backflow <br />prevention device. <br />Bubbler symbols are shown <br />diagrammatically, located <br />bubblers at each tree, typ. <br />Bubbler symbols are shown <br />diagrammatically, located <br />bubblers at each tree, typ. <br />(1) 4" sleeves <br />(3) 3" sleeve <br />Install quick coupler <br />adjacent to trash <br />enclosure <br />C <br />W <br />Controller <br />Locate controller on wall of the <br />trash enclosure. Extend electrical <br />supply to controller. Final location <br />to be determined in field. <br />Weather Sensor <br />Locate weather sensor on <br />eave of building in nearby <br />location with unimpeded <br />rainfall and sunlight and <br />connect to controller. <br />Irrigation Sleeves <br />Install sleeves prior to <br />placement of paving and final <br />sub-grade preparation. Refer to <br />Legend for size and quantity at <br />each location, typ. <br />3 4" <br />3 4" <br />3 4" <br />1" <br />3 4" <br />114" <br />1"3 4" <br />112" <br />3 4" <br />3 4" <br />3 4" <br />3 4"3 4" <br />114"114" <br />114" <br />114"114"114" <br />17.98 <br />1"52.02 <br />1" <br />66.16 <br />1" <br />72.04 <br />1" <br />83.59 <br />1" <br />17.09 <br />1" <br />FF F F F <br />F <br />F <br />FF <br />F F <br />114" <br />Commerce CourtCommerce CourtAdj. Retail <br />Proposed <br />Building <br />T <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION ARC PSI GPM RADIUS DETAIL <br />Hunter RZWS-SLEEVE-18-CV 25 360 20 0.25 3'H/L5.1 <br />18" long with 0.25 gpm bubbler, Check Valve, and 1/2" swing <br />joint. Install two (2) at each tree, locate on opposite sides of the <br />tree and adjacent to the root ball. <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL <br />Hunter ICZ-101-25-LF G/L5.1 <br />Drip Control Zone Kit. Globe valve with filter system, valve size <br />per valve callout. Pressure Regulation: 25psi. 150 mesh <br />stainless steel screen. <br />Toro T-FCH-H-FIPT C/L5.2 <br />Flush valve, plumbed to flush manifold at low point or at end of <br />supply line of each zone. Install in 6" round plastic valve box. <br />Area to Receive Drip Emitters <br />Hunter HE-B A/L5.2 <br />Point Source Drip Emitter with Self Piercing Barb with diffuser <br />cap. Install on 5/8" or 3/4” polyethylene supply tubing to each <br />plant. Install emitters equally around the plant at the rates <br />provided below. Install supply tubing min. 3" below grade with <br />staples 5’ oc max. Provide flush valve in 6" round plastic box at <br />the end of each assembly. Locate on uphill side of plant; evenly <br />space around root ball at locations with multiple emitters. <br />Emitter Notes: <br />20HE-B emitters (1 assigned to each 1 gal. plant) <br />05HE-B emitters (2 assigned to each 5 gal. plant) <br />20HE-B emitters (4 assigned to each 15 gal. plant) <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL <br />Hunter ICV-G F/L5.1 <br />Plastic Electric Remote-Control Valve, Globe Configuration, with <br />NPT Threaded Inlet/Outlet, size per plans <br />Hunter HQ-44LRC D/L5.1 <br />Quick coupler valve, yellow rubber locking cover, red brass and <br />stainless steel, with 1" NPT inlet, 2-piece body. <br />Nibco T-113-K C/L5.1 <br />Class 125 bronze gate valve, same size as mainline pipe <br />diameter at valve location. <br />Hunter ICV-G 1"E/L5.1 <br />Electric Plastic In-Line Master Valve. Standard Solenoid. Globe <br />Body Style. Size per plans. <br />Hunter IC-0600-M A/L5.1 <br />Controller, outdoor model, provide expansion modules for <br />required number of stations. Include options to work with flow <br />and weather sensors. Provide and connect to electrical supply. <br />Final location determined in field with Owner`s representative or <br />Architect. <br />Hunter WSS-SEN B/L5.1 <br />Wireless weather sensor with manufacturer-provided mounting <br />bracket. Verify compatibility with controller. Locate so that <br />sensor receives unimpeded sunlight and rainfall, connect to <br />controller. <br />Creative Sensor Technology FSI-T10-001 E/L5.1 <br />Creative Sensor Technology, 1” PVC flow sensor. Verify <br />compatibility with controller. <br />Point of Connection 2" <br />Meter and backflow, per civil engieneer`s plans. Design based <br />on 52 psi in street, verify and notify owner and landscape <br />architect if different and for resulting design modification, as <br />needed. <br />Irrigation Lateral Line: PVC Schedule 40 D/L5.2 <br />Irrigation Mainline: PVC Schedule 40 D/L5.2 <br />Pipe Sleeve: PVC Class 200 SDR 21 E/L5.2 <br />Install dbl. 3" (min.) sleeves at each location on the plan. For <br />pipes 2" and greater install sleeves at twice the diameter of the <br />pipe. <br />F <br />M <br />C <br />W <br />FS <br />POC <br />#" <br /># <br />Valve Number <br />Valve Size <br />Valve Flow <br />Valve Callout <br /># <br />IRRIGATION SCHEDULE <br />L3.1 <br />Irrigation <br />Plan <br />Checked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, Inc. <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />450 COMMERCE COURT <br />MANTECA, CA 95336 <br />11/13/2020 3:11:00 PMRSH <br />RSH <br />18-077 (SHLA 19-008) <br />PERMIT SUBMITTAL <br />06.02.2021 <br />MACHADO SPORTS COMPLEX <br />1020 MARSH CREEK <br />EBMA INVESTMENTS <br />MANTECA, CA, 95336 <br />No.Description Date By <br />S a m H a r n e d <br />L a n d s c a p e <br />A r c h i t e c t u r e <br />P O B o x 2 2 7 5 <br />O a k d a l e , C A 9 5 3 6 1 <br />w w w .h a r n e d l a .c o m <br />2 0 9 -3 8 0 -7 3 7 6 <br />07 June 2021 <br />NORTH <br />Notes: <br />1.See Sheet L7.1 for <br />WELO calculations and <br />notes, and valve table. <br />0'10'20'40' <br />scale: 1" = 20'-0"Matchline A - See Sheet L3.21.Contractor shall become familiar with the drawings, specifications, and site conditions prior to beginning work. <br />Should conflicting information be found in these documents or between these documents and site conditions, <br />notify the Landscape Architect before proceeding with the work in question. <br />2.All existing utilities, water lines, and fire hydrants shall remain connected and in full continuous operation unless <br />specifically directed otherwise. <br />3.Irrigation design is based on a minimum 80 psi and maximum 100 psi static water pressure at the point of <br />connection after the water meter. Verify prior to ordering materials or starting work. Notify the Landscape <br />Architect if water pressure differs from pressure on which the design is based. Variation from design pressure <br />may require changes and additions to the equipment specifications. <br />3.1.Booster Pump: If verified static pressure is less than minimum required design pressure, provide a booster <br />pump as appropriate to yield the required minimum pressure based on anticipated maximum and <br />minimum flows required for system to operate within water window requirements. <br />3.2.Pressure Regulator: If verified static pressure is more than maximum, design pressure, provide a pressure <br />regulator as appropriate to yield the required pressure based on anticipated maximum and minimum <br />flows required for system to operate within water window requirements. <br />4.Irrigation plan is diagrammatic. Actual routing of pipe and location of equipment shall be determined based on <br />field conditions and as directed by the Landscape Architect. Install pipe and equipment in landscape areas <br />wherever possible unless specifically noted otherwise. Stake layout of mainline and primary laterals for field <br />review and approval prior to trenching. Field adjust existing irrigation system as necessary. <br />5.Pipe Sizing: <br />5.1.Minimum pipe size shall be 3/4". <br />5.2.Unlabeled pipe segments shall be equal to the size of the segment immediately upstream. <br />5.3.In making adjustments to irrigation zone layouts Contractor shall be responsible to determine pipe sizes as <br />required to deliver water pressure required for each outlet device considering flow rate, elevation <br />changes, length of run, and other factors affecting pressure loss. Maximum flows in various pipe sizes <br />shall not exceed the following guidelines. Flows may may need to be significantly less than the <br />maximums stated below to off-set other factors affecting pressure loss: <br />5.3.1.3/4":up to 6 gpm. <br />5.3.2.1":6 to 8 gpm. <br />5.3.3.1-1/4":8 to 16 gpm. <br />5.3.4.1-1/2":16 to 23 gpm. <br />5.3.5.2":23 to 38 gpm. <br />5.4.Mainline pipe sizes shall not be changed without written approval of the Landscape Architect. <br />5.5.Lateral line pipe runs of lengths greater than the typical distance between outlet devices shall not be made <br />without written approval of the Landscape Architect. <br />6.Do not install the irrigation system as shown on the drawings when it is obvious in the field that obstructions, <br />grade differences or differences in the area dimensions exist that might not have been considered in the <br />engineering. Notify the Landscape Architect of all such conditions immediately upon discovery. In the event this <br />notification is not provided, the Contractor shall assume full responsibility for all revisions necessary in response <br />to field conditions with no additional compensation. <br />7. Controller(s): <br />7.1.Locate as directed. Extend electrical service to controllers and dedicate one breaker of proper size for <br />each controller. Provide one additional duplex outlet at each controller location. <br />7.2.Electrical service to controllers shall be completed by a licensed electrical contractor in accordance with all <br />applicable codes. <br />8.Sleeves: <br />8.1.All pipe under existing and proposed paving shall be installed in sleeves. <br />8.2.Sleeves are shown for contractor's convenience. Contractor shall be responsible to coordinate irrigation <br />sleeve locations and installation with other trades. <br />8.3.Extend all sleeves 18 inches beyond paving, cap and clearly mark by approved means to facilitate <br />recovery. <br />8.4.Install sleeves to accommodate future paving where indicated or as may be needed. <br />9.Spray Heads and Rotors: <br />9.1.Install perpendicular to grade unless otherwise noted in plans. <br />10.Drip Emitters: <br />10.1.Install drip supply lines minimum 3" below grade. <br />10.2.Located emitters 3"-6" from main trunk or stem. <br />10.3.Include bug-guard and galvanized stake(s) for each emitter. <br />11. Contractor to flush entire system and adjust all delivery devices and assemblies for complete coverage and <br />reduced over-spray, prior to project completion. <br />12.An irrigation audit shall be completed by a Certified Landscape Irrigation Auditor in conformance with the <br />jurisdictional Water Efficient Landscape Ordinance (WELO or MWELO). The audit shall be provided to the <br />jurisdictional agency for review and approval. <br />IRRIGATION NOTES <br />SUPPLEMENTAL IRRIGATION SYMBOL LEGEND <br />Break between drip areas on different circuits. <br />Symbol <br />Item Description <br />Losses (in psi) <br />Lateral 2.00 <br />Fittings 0.20 <br />Remote control valve 2.80 <br />Main line 0.79 <br />Master Valve 2.80 <br />Backflow 12.00 <br />Meter 0.40 <br />Elev. loss POC to valve 0.00 <br />Total losses:20.99 psi <br />CRITICAL CIRCUIT PRESSURE LOSS CALCULATIONS <br />Station: 4 <br />Station flow: 7.14 gpm <br />Available static <br />pressure at City supply: 52.0 psi <br />Pressure loss through system:20.99 psi <br />Available pressure:31.01 psi <br />Pressure required:25.0 psi <br />I have complied with the criteria of the water efficient landscape ordinance and applied <br />them accordingly for the efficient use of water in the landscape design plans. <br />WELO COMPLIANCE STATEMENT <br />Sam Harned <br />CLA #4881 <br />Date <br />07 June 2021 <br />6/8/2021, 1:58:25 PM <br />21-0396 <br />LUMEN ARCEO