My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COMMERCE
>
450
>
1600 - Food Program
>
PR0547667
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:24:52 AM
Creation date
5/12/2022 4:32:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547667
PE
1620
FACILITY_ID
FA0027137
FACILITY_NAME
COURTSIDE SPORTS MANTECA
STREET_NUMBER
450
STREET_NAME
COMMERCE
STREET_TYPE
CT
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
450 COMMERCE CT
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Bubbler symbols are shown <br />diagrammatically, located <br />bubblers at each tree, typ. <br />Irrigation Sleeves <br />Install sleeves prior to placement of <br />paving and final sub-grade <br />preparation. Refer to Legend for size <br />and quantity at each location, typ. <br />3 4" <br />3 4" <br />1" <br />3 4" <br />3 4" <br />3 4" <br />3 4" <br />3 4" <br />25.33 <br />1" <br />32.04 <br />1" <br />47.14 <br />1" <br />Mainline <br />Shown schematically. Install <br />along back of walk or curb as <br />feasible. Group valves in <br />shrub areas. <br />F <br />F <br />F <br />F <br />FF <br />F <br />Adj. Retail <br />Adj. Office <br />Proposed <br />Building <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION ARC PSI GPM RADIUS DETAIL <br />Hunter RZWS-SLEEVE-18-CV 25 360 20 0.25 3'H/L5.1 <br />18" long with 0.25 gpm bubbler, Check Valve, and 1/2" swing <br />joint. Install two (2) at each tree, locate on opposite sides of the <br />tree and adjacent to the root ball. <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL <br />Hunter ICZ-101-25-LF G/L5.1 <br />Drip Control Zone Kit. Globe valve with filter system, valve size <br />per valve callout. Pressure Regulation: 25psi. 150 mesh <br />stainless steel screen. <br />Toro T-FCH-H-FIPT C/L5.2 <br />Flush valve, plumbed to flush manifold at low point or at end of <br />supply line of each zone. Install in 6" round plastic valve box. <br />Area to Receive Drip Emitters <br />Hunter HE-B A/L5.2 <br />Point Source Drip Emitter with Self Piercing Barb with diffuser <br />cap. Install on 5/8" or 3/4” polyethylene supply tubing to each <br />plant. Install emitters equally around the plant at the rates <br />provided below. Install supply tubing min. 3" below grade with <br />staples 5’ oc max. Provide flush valve in 6" round plastic box at <br />the end of each assembly. Locate on uphill side of plant; evenly <br />space around root ball at locations with multiple emitters. <br />Emitter Notes: <br />20HE-B emitters (1 assigned to each 1 gal. plant) <br />05HE-B emitters (2 assigned to each 5 gal. plant) <br />20HE-B emitters (4 assigned to each 15 gal. plant) <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL <br />Hunter ICV-G F/L5.1 <br />Plastic Electric Remote-Control Valve, Globe Configuration, with <br />NPT Threaded Inlet/Outlet, size per plans <br />Hunter HQ-44LRC D/L5.1 <br />Quick coupler valve, yellow rubber locking cover, red brass and <br />stainless steel, with 1" NPT inlet, 2-piece body. <br />Nibco T-113-K C/L5.1 <br />Class 125 bronze gate valve, same size as mainline pipe <br />diameter at valve location. <br />Hunter ICV-G 1"E/L5.1 <br />Electric Plastic In-Line Master Valve. Standard Solenoid. Globe <br />Body Style. Size per plans. <br />Hunter IC-0600-M A/L5.1 <br />Controller, outdoor model, provide expansion modules for <br />required number of stations. Include options to work with flow <br />and weather sensors. Provide and connect to electrical supply. <br />Final location determined in field with Owner`s representative or <br />Architect. <br />Hunter WSS-SEN B/L5.1 <br />Wireless weather sensor with manufacturer-provided mounting <br />bracket. Verify compatibility with controller. Locate so that <br />sensor receives unimpeded sunlight and rainfall, connect to <br />controller. <br />Creative Sensor Technology FSI-T10-001 E/L5.1 <br />Creative Sensor Technology, 1” PVC flow sensor. Verify <br />compatibility with controller. <br />Point of Connection 2" <br />Meter and backflow, per civil engieneer`s plans. Design based <br />on 52 psi in street, verify and notify owner and landscape <br />architect if different and for resulting design modification, as <br />needed. <br />Irrigation Lateral Line: PVC Schedule 40 D/L5.2 <br />Irrigation Mainline: PVC Schedule 40 D/L5.2 <br />Pipe Sleeve: PVC Class 200 SDR 21 E/L5.2 <br />Install dbl. 3" (min.) sleeves at each location on the plan. For <br />pipes 2" and greater install sleeves at twice the diameter of the <br />pipe. <br />F <br />M <br />C <br />W <br />FS <br />POC <br />#" <br /># <br />Valve Number <br />Valve Size <br />Valve Flow <br />Valve Callout <br /># <br />IRRIGATION SCHEDULE <br />L3.2 <br />Irrigation <br />Plan <br />Checked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, Inc. <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />450 COMMERCE COURT <br />MANTECA, CA 95336 <br />11/13/2020 3:11:00 PMRSH <br />RSH <br />18-077 (SHLA 19-008) <br />PERMIT SUBMITTAL <br />06.02.2021 <br />MACHADO SPORTS COMPLEX <br />1020 MARSH CREEK <br />EBMA INVESTMENTS <br />MANTECA, CA, 95336 <br />No.Description Date By <br />S a m H a r n e d <br />L a n d s c a p e <br />A r c h i t e c t u r e <br />P O B o x 2 2 7 5 <br />O a k d a l e , C A 9 5 3 6 1 <br />w w w .h a r n e d l a .c o m <br />2 0 9 -3 8 0 -7 3 7 6 <br />07 June 2021 <br />NORTH <br />Notes: <br />1.See Sheet L7.1 for WELO calculations <br />and notes, and valve table. <br />0'10'20'40' <br />scale: 1" = 20'-0"Matchline A - See Sheet L3.1SUPPLEMENTAL IRRIGATION SYMBOL LEGEND <br />Break between drip areas on different circuits. <br />Symbol Item Description <br />6/8/2021, 1:58:25 PM <br />21-0396 <br />LUMEN ARCEO
The URL can be used to link to this page
Your browser does not support the video tag.