Laserfiche WebLink
L5.1 <br />Irrigation <br />Details <br />Checked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, Inc. <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />450 COMMERCE COURT <br />MANTECA, CA 95336 <br />11/13/2020 3:11:00 PMRSH <br />RSH <br />18-077 (SHLA 19-008) <br />PERMIT SUBMITTAL <br />06.02.2021 <br />MACHADO SPORTS COMPLEX <br />1020 MARSH CREEK <br />EBMA INVESTMENTS <br />MANTECA, CA, 95336 <br />No.Description Date By <br />S a m H a r n e d <br />L a n d s c a p e <br />A r c h i t e c t u r e <br />P O B o x 2 2 7 5 <br />O a k d a l e , C A 9 5 3 6 1 <br />w w w .h a r n e d l a .c o m <br />2 0 9 -3 8 0 -7 3 7 6 <br />07 June 202160", or as otherwiseapproved.18" min.Irrigation controller, per Irrigation <br />Schedule. Final location determined <br />in the field with owner. Securely bolt <br />or screw to wall. <br />110/120 VAC power supply and <br />rigid conduit. <br />Wiring to valves <br />Sch. 40 rigid PVC UL conduit for control <br />wiring (size as req'd). Install conduit during <br />building construction, cap to prevent debris <br />from entering open end. Coordinate as req'd <br />prior to pouring building foundation. Extend <br />conduit to controller with controller install. <br />Exterior wall, when occurs <br />Foundation, when occurs <br />Terminate conduit <br />in landscape area <br />Wall, may be interior or exterior, <br />see Irrigation Plan for location <br />NOTES: <br />1.Detail shows exterior and interior <br />wall mount conditions. Install <br />appropriate controller based on <br />project conditions. <br />2.Installation to conform to <br />manufacturer's recommendations <br />and per local governing codes. <br />3.All electrical to be installed by a <br />properly certified electrician. <br />CONTROLLER - WALL MOUNT <br />NTS <br />Sweep ell <br />Finish grade/ Finish surface, per plan <br />18" min. <br />A <br />328401-02 <br />Bracket arm attachment, <br />provided by manufacturer <br />Wall, building parapet, or other <br />similar feature as described on <br />Irrigation Plan <br />WEATHER SENSOR - WALL OR ROOF MOUNT <br />NTS <br />Weather sensor, per <br />Irrigation Schedule. <br />Securely attached bracket with anchor bolts and <br />wedge anchors into masonry or concrete, or <br />screws into wood or metal. Water seal all <br />penetrations into building wall. <br />NOTES: <br />1.Install per manufacturer's instructions. <br />2.Install sensor in location that receives <br />direct sunlight and unimpeded rainfall. <br />3.Confirm connection with controller <br />upon start-up. <br />4.Detail shows multiple connection <br />situations; install per specific project <br />situation, per plans. <br />WALL OR PARAPET MOUNT <br />EAVE MOUNT <br />Weather sensor, <br />per Irrigation <br />Schedule. <br />Bracket arm attachment, <br />provided by manufacturer <br />Roof, shown diagrammatically, <br />actual roof design may vary <br />Wood fascia <br />Securely attached bracket <br />with exterior grade coarse <br />thread wood screws <br />B <br />328401-05 <br />GATE VALVE - UP TO 3" <br />NTS Depth per sheetspecs or localcode (18" U.O.N.)Finish grade <br />PVC pipe <br />extension, length <br />as req'd <br />6" Sch. 80 PVC threaded <br />nipple, ea. side <br />3/4" drain rock <br />10" round plastic valve box. <br />Use green box for potable <br />water systems, purple for <br />non-potable systems. <br />Gate valve, line size. <br />See Irrigation Legend <br />for product info.8" min.Coupling (SxT)2"Common brick <br />support, min. 3 <br />Main line <br />C <br />328401-09 <br />Sch. 80 PVC nipple, <br />length as required <br />Quick coupler valve - <br />see plan for mftr and <br />model <br />QUICK COUPLER <br />NTS <br />(3) stainless steel clamps <br />#3 rebar stake x 30" <br />10" dia. valve box <br />2"Sch. 80 PVC ell, (3) total <br />Sch. 80 PVC nipple Common brick supports, <br />equally spaced, min. 2 <br />6" min.3 4" dia. drain rock <br />Main line, per plan <br />Sch. 80 nipple, length as <br />required, connect with <br />main line tee or ell <br />NOTES: <br />1. Valve box lids shall be tagged or branded with "q.c." <br />2. Mainline stub, nipples, & fittings shall match valve size. <br />D <br />328401-10 <br />MASTER VALVE AND FLOW SENSOR <br />NTS <br />3/4" dia. drain rock, min. 6" depth <br />Brick supports at corners <br />(typ.) <br />Rectangular plastic valve box, <br />per specs. <br />Waterproof wire connectors, <br />per specs <br />Control wires, provide 24"-30" <br />separated coil of ea. wire <br />(2) Sch. 80 PVC union (TxT) <br />Sch. 40 PVC apatper (SxT) <br />Main line from P.O.C 2"Finish grade <br />Rectangular plastic valve <br />box, per specs. <br />Master valve, per Irrigation Schedule <br />Flow sensor wires, per <br />manufacturer's <br />recommendations, <br />locate in 1" elec. conduit <br />to controller <br />3/4" dia. drain rock, min. 6" depth <br />Waterproof wire <br />connectors, per specs <br />Flow sensor, per Irrigation Schedule <br />Min. 10x pipe diameter. No <br />valves, reducers, or elbows <br />in this area. <br />Min. 5x pipe diameter. <br />No valves, reducers, <br />or elbows in this area. <br />PVC main line, with adapter <br />as required <br />Flow <br />Note: <br />1.Control wire shall be direct burial 14 AWG or <br />larger. <br />2.All wire runs shall be continuous without any <br />splices unless approved by the Owner's <br />Representative. Wire connections shall be made <br />using DBR/Y-6 connectors or approved equal. <br />3.All Sch. 80 PVC to Sch. 40 PVC threaded <br />connections shall be made using teflon tape. <br />4.Valve boxes shall be located in planting areas. <br />E <br />328401-01 <br />REMOTE CONTROL VALVE <br />NTS <br />3/4" dia. drain rock, <br />min. 6" depth <br />Brick supports at <br />4 corners <br />PVC main line <br />Sch. 40 or 80 PVC <br />tee or ell (SxT) <br />Sch. 80 PVC nipple <br />(length as required) <br />Sch. 80 PVC 90 ell (TxT) <br />Sch. 80 PVC nipples at <br />union valves, 3" min, typ. <br />PVC true union ball <br />valve <br />Remote control valve, <br />see Irrigation Schedule <br />for info <br />Rectangular plastic <br />valve box, per specs.2" (Planterareas)1" (turf)Water-proof tag, <br />provide station <br />number based on <br />plans <br />Waterproof wire <br />connectors, per specs <br />Control wires, provide <br />24"-30" separated coil of <br />ea. wire <br />PVC lateral pipe <br />PVC true union <br />ball valve <br />Note: <br />1.Control wire shall be direct burial 14 AWG <br />or larger. <br />2.All wire runs shall be continuous without any <br />splices unless approved by the Owner's <br />Representative. Wire connections shall be <br />made using DBR/Y-6 connectors or <br />approved equal. <br />3.All Sch. 80 PVC to Sch. 40 PVC threaded <br />connections shall be made using teflon tape. <br />4.Valve boxes shall be located in planting <br />areas. <br />F <br />328401-12 <br />Notes: <br />1.Control wire shall be direct burial 14 AWG or larger. <br />2.One valve per valve box only - no exceptions. <br />3.Valve boxes to be located in shrub areas wherever <br />possible, group valves together.2" at planterarea, 1" atturfPVC true union ball valve <br />Plastic jumbo rectangular <br />valve box, per specs.3"min.Finish grade <br />Sch. 80 PVC nipples <br />(min. 3" length) <br />Remote control valve, see Irrigation <br />Schedule for info <br />Control wires, provide 24"-30" <br />separated coil of ea. wire <br />Waterproof wire <br />connectors, per specs <br />Water-proof tag, <br />provide station number <br />based on design in <br />plans <br />Filter. May be Wye or Basket <br />style, based on specified valve <br />Pressure regulator, per <br />specified valve <br />Sch. 80 PVC union <br />(TxT) with short Sch. <br />80 PVC nipples <br />Sch. 40 PVC pipe or <br />80 PVC nipple <br />(length as required) <br />Sch. 80 PVC ell (TxT) <br />Sch. 40 or 80 PVC <br />tee or ell (SxT) <br />PVC main line PVC lateral line <br />3/4" dia. drain rock, min. 6" depth <br />Sch. 40 PVC male <br />adapter (SxT) <br />Brick supports at <br />4 corners <br />PVC outlet pipe, <br />same size as valve <br />for min. 24" to first <br />fitting <br />REMOTE CONTROL DRIP VALVE <br />1 1/2" = 1'-0"G <br />328401.01-14 <br />Plant pit <br />Root ball <br />Undisturbed <br />native soil <br />TREE ROOT WATERING SYSTEM <br />NTS 2"Tree root watering <br />assembly, locate <br />equidistant around <br />tree and adjacent <br />to root ball. See <br />Irrigation Schedule <br />for product info. <br />Set top of assembly <br />above FB, do not <br />cover with mulch <br />Soil sock,when <br />specified, see <br />Irrigation <br />Schedule <br />Lateral line <br />PVC fitting <br />Swing joint or <br />flexible assembly, <br />as comes with <br />specified model <br />Top of mulch layer <br />FG <br />Tree <br />Amended <br />backfill mix <br />H <br />328401-17 <br />6/8/2021, 1:58:25 PM <br />21-0396 <br />LUMEN ARCEO