My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COMMERCE
>
450
>
1600 - Food Program
>
PR0547667
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:24:52 AM
Creation date
5/12/2022 4:32:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547667
PE
1620
FACILITY_ID
FA0027137
FACILITY_NAME
COURTSIDE SPORTS MANTECA
STREET_NUMBER
450
STREET_NAME
COMMERCE
STREET_TYPE
CT
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
450 COMMERCE CT
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L5.2 <br />Irrigation <br />Details <br />Checked By: <br />Drawn By: <br />Project No.: <br />LDA Partners, Inc. <br />Designers & Architects <br />222 Central Court <br />Stockton, CA 95204 <br />209.943.0405 <br />www.ldapartners.com <br />Client: <br />Architect: <br />Project: <br />450 COMMERCE COURT <br />MANTECA, CA 95336 <br />11/13/2020 3:11:00 PMRSH <br />RSH <br />18-077 (SHLA 19-008) <br />PERMIT SUBMITTAL <br />06.02.2021 <br />MACHADO SPORTS COMPLEX <br />1020 MARSH CREEK <br />EBMA INVESTMENTS <br />MANTECA, CA, 95336 <br />No.Description Date By <br />S a m H a r n e d <br />L a n d s c a p e <br />A r c h i t e c t u r e <br />P O B o x 2 2 7 5 <br />O a k d a l e , C A 9 5 3 6 1 <br />w w w .h a r n e d l a .c o m <br />2 0 9 -3 8 0 -7 3 7 6 <br />07 June 2021 <br />DRIP FLUSH CAP <br />NTS 3" (2" min)Top dressing/ mulch layer <br />Finish grade <br />Adjust mulch to be just <br />under top of box, do not <br />completely cover lid <br />6" round plastic valve box <br />Compression ell <br />Drip tubing supply line <br />Trip tubing, 6"± <br />Flush cap or valve, per <br />Irrigation Schedule <br />Drain rock, min. 6" depth <br />C <br />328401.01-24 <br />NOTES: <br />1.See irrigation legend for mainline and lateral line pipe <br />size and type. <br />2.Direct burial control wires shall be installed in Sch. 40 <br />PVC electrical conduit if required. <br />3.2-wire irrigation wire shall be installed in Sch. 40 PVC <br />electrical conduit. <br />4.Detectable locator tape shall be located six inches (6") <br />above the entire mainline run. <br />24" min.12"in planting area18" in planting area36" underneath pavement6"Finish grade Paving <br />Lateral line <br />(non-pressurized line). <br />Detectable locator tape. <br />Pressurized line <br />(mainline). <br />Direct burial low voltage <br />control wires, bundled <br />and taped. <br />TRENCHING <br />NTS <br />Backfill trench with suitable <br />material, see specs. <br />D <br />328401-29 <br />24" min.12" min.3" min.Notes: <br />1.Install sleeves side-by-side when more than one <br />sleeve occurs in the same trench. <br />2.Irrigation wires shall be sleeved in separate Sch. 40 <br />PVC electrical conduit.12"Temporary riser marker, <br />cap and paint with <br />orange marking paint <br />Finish <br />grade <br />Temporary PVC <br />90°elbow. <br />Paving or other <br />hardscape element <br />Sch. 40 PVC sleeve <br />Irrigation PVC main or <br />lateral, install with sleeve <br />IRRIGATION SLEEVE <br />NTS 24" min.12" min.3" min.12"Redwood 2x4 or <br />4x4 marker <br />Finish <br />grade <br />Paving or other <br />hardscape <br />element <br />6" <br />min. <br />Temporary cap, <br />secure with <br />duct tape <br />Sch. 40 PVC sleeve <br />Irrigation PVC main or <br />lateral, install with sleeve <br />ALTERNATE MARKER <br />E <br />328401-26 <br />NOTES: <br />1.When planting on a slope, <br />locate majority of emitters <br />on up-slope side of plant. <br />2.Locate emitters 3"- 6" from <br />base of shrubs/ground <br />covers, and 6"- 9" from <br />tree trunks, unless <br />otherwise indicated. <br />3.Space emitters equally <br />around plant when <br />multiple emitters are <br />specified. <br />Bug plug, typ. at all <br />ends of 1/4" tubing <br />6" plastic stake at end <br />of ea. tube, elevate <br />end of tube just above <br />mulch level3", <br /> <br />U <br />. <br />O <br />. <br />N <br />fro <br />m <br /> <br />v <br />a <br />l <br />v <br />e <br />per <br />spec <br />s <br />PVC tee or ell, typ. <br />PVC lateral line <br />PVC to poly <br />tubing adapter <br />Poly drip tubing per plan <br />- bury 3" below grade; <br />tubing set above grade <br />under mulch is not <br />acceptable, U.O.N. <br />6" galv. steel <br />staple @ 4' o.c. <br />max spacing <br />Plant <br />RootballFinish grade <br />1/4" vinyl distribution <br />tubing, 30" max. length <br />Drip emitter, qty. and model <br />per Irrigation Schedule <br />Poly distribution tubing <br />lateral, as occurs <br />Sch. 40 PVC pipe riser <br />DRIP EMITTER ASSEMBLY <br />1" = 1"A <br />Detail not <br />used <br />6/8/2021, 1:58:25 PM <br />21-0396 <br />LUMEN ARCEO
The URL can be used to link to this page
Your browser does not support the video tag.