My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
INSTALL_2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 4:53:16 PM
Creation date
5/12/2022 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2001
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVES COUNTRY STORES OF CALIFORNIA #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
209
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Flexible Underground Piping Manual environ <br /> 3.4 Metallic Product Offset 4.2 Test Tubes <br /> This specialty fitting is used to These 36"long plastic tube assemblies <br /> radically offset the steel riser pipe to are designed to provide access to the <br /> accommodate certain dispensers beginning and end of the interstitial <br /> having pipe entry inlets significantly space of GeoFlex-D double wall pipe _ <br /> off the center line. This fitting has line for initial and periodic air pressure <br /> 1-1/2" NPT female threads on each testing. There are two types of test <br /> opening. tubes available for use. One type is <br /> used with test boots and fitted with a <br /> barbed elbow and stainless steel band <br /> clamp on the lower end for insertion <br /> and clamping into the test boot port.The other type,the coax test <br /> 3.5 Metallic Dual Adapters tube is used with the coax pipe adapter and fitted with a 1/4" NPT <br /> This metallic adapter is designed to male nylon threaded fitting for connection to the threaded test port. <br /> accommodate two flexible piping <br /> lines exiting a tank sump. This 4.3 Connector Tubes <br /> adapter has a 2" NPT female These short plastic tube assemblies are <br /> threaded opening at the top end and designed to reroute the interstitial space <br /> two downward facing openings of one GeoFlex-D flexible pipe section 1 <br /> which provide 1-1/2" NPT male around a metallic junction tee fitting to <br /> threads.Typically these adapters are the next GeoFlex-D flexible pipe section. <br /> part of a plumbing tree and fitted on They come fitted on each end with a <br /> the ends with conventional female 2" x 1-1/2" reducing elbows. barbed elbow and stainless steel band <br /> Dual adapters may also be used for 2" piping lines. clamp for insertion and clamping into <br /> the test boot port. Connector tubes are <br /> 4available t different lengths to <br /> .0 (GEOFLEXO) PIPE ACCESSORIES <br /> accommodate either 1-1/2", 2" or 3" <br /> There are a variety of accessory components which may be metallic junction tees for both swivel and barbed fittings. <br /> used with the GeoFlex piping system. <br /> NOTE: The connector tubes cannot be used with <br /> GeoRexS and coax fittings and couplings. <br /> 4.1 Standard Test Boots and Reducer Test Boots 4.4 Crossover Supports <br /> GeoFlex®-D piping fitted with either swivel couplings and These two piece supports are used <br /> fittings or barbed fittings can incorporate the use of rubber test to separate GeoFlex and GeoVent" <br /> boots and small diameter plastic tubing for purposes of flexible piping runs at all crossover <br /> providing access to and interconnecting of the interstitial space intersections, providing sufficient <br /> of the GeoFlex-D piping. One end of the rubber test boot support to prevent the upper pipe el"00 <br /> clamps down onto the outside of the green secondary jacket from deforming the lower pipe. <br /> and the other end of the boot is clamped onto the outside of the <br /> ferrule of the swivel pipe coupling (standard test boots)or onto <br /> the outside surface of the primary pipe when barbed fittings are <br /> used (reducer test boots).The test boot includes a rubber boot <br /> and two band clamps. 5.0 INSTALLER TOOLS <br /> NOTE: The test boots cannot be used with GeoFlex-S Environ offers a variety of Installer <br /> and coax fittings &couplings. Tools for installing contractors for <br /> faster installations. To insure proper <br /> installation and product warranty <br /> coverage, only Environ pipe <br /> coupling equipment and pipe <br /> fabricating tools should be used. <br /> 5.1 Pipe Cutter <br /> ��� The GeoFlex pipe cutter is designed <br /> to produce the clean and even pipe <br /> cuts which are necessary for proper <br /> coupling attachment. <br /> NOTE: A conventional fine <br /> tooth hand saw is also <br /> permitted to cut the pipe <br /> providing all edges are cleaned <br /> with either a knife or sandpaper. <br /> 6 <br />