My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
INSTALL_2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 4:53:16 PM
Creation date
5/12/2022 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2001
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVES COUNTRY STORES OF CALIFORNIA #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
209
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' JAN-22-1900 17:59 P.03 <br /> FE Petro, Inc. <br /> STP-MLD-HC Pipeline Leak Detector <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with PD= 100% and PFA:z 0%. <br /> Leak Threshold: 2.0 gph. A pipeline system should not be declared tight if the test <br /> result indicates a loss that equals or exceeds this threshold. <br /> Applicability: Gasoline, diesel, aviation fuel_ <br /> Other liquids may be tested after consultation with the manufacturer_ <br /> Specification: System tests rigid pipelines. <br /> Tests are conducted at operating pressure_ <br /> Pipeline Capacity:Maximum of 172 gallons. <br /> Waiting Time: None between delivery and testing. 11*f4pp <br /> None between dispensing and testing. <br /> Test Period: Response time is less than 30 seconds. <br /> System Features: Permanent installation on pipeline. <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration: System must be checked annually and calibrated if necessary in <br /> accordance with manufacturer's instructions. <br /> Comments: Test conducted using gasoline in 200 feet of 3.25 inch fiberglass <br /> pipe. <br /> FE Petro, Inc. Evaluator- Ken Wilcox Associates, Inc. <br /> 4805 Voges Rd Tel: (816) 443-2494 <br /> McFarland,W153558 Date of Evaluation: 1.1/7/2000 <br /> Tel: (608) 838-8786 <br /> TOTAL P.03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.