Laserfiche WebLink
OPW 61 SO 0 ERFILL PREVE TION VALVES <br /> Our Patented Design is the Features of the 61SO Series: <br /> Most Effective and the ♦Simple, Easy And Quick <br /> Most Versatile. Installation-No excavation or <br /> The OPW 61 SO Overfill Prevention special manholes required. <br /> Valve is designed to prevent the overfill *Economical -Costs a fraction of <br /> of underground storage tanks by pro- expensive,complicated and difficult <br /> viding a positive shut-off of product to install valves. <br /> delivery.The shut-off valve is an inte- ♦Furnished Complete - Supplied <br /> gral part of the drop tube used for grav- with new upper and lower drop- <br /> ity filling.The OPW 61SO allows easy tubes, mounting hardware and <br /> installation(without breaking concrete) thorough instructions for quick job <br /> and requires no special manholes. site time. <br /> The OPW 61SO is a two-stage shut- Completely Automatic Operation - <br /> off valve.When the liquid level rises to No prechecks to perform, no resets, <br /> about 95%of tank capacity,the valve and no overrides to be broken or <br /> mechanism is released closing automat- abused. <br /> ically with the flow.This reduces the ♦No Pressurization Of The Tank - <br /> flow rate to approximately 5 gpm Operates directly from liquid level. <br /> through a bypass valve.The operator ♦Will Accept A Dipstick For Gauging. <br /> may then stop the filling process and ♦Retrofits Directly-For both new <br /> disconnect and drain the delivery hose. and existing tanks with 3" or 4" fill <br /> As long as the liquid exceeds the 95% risers. <br /> level,the valve will close automatically *Quick Drain Feature- <br /> .ach time delivery is attempted. Automatically drains hose when <br /> If the delivery is not stopped and the head pressure is relieved. <br /> liquid rises to about 98%of tank capac- *gest Flow Rate In The Industry.* <br /> ity,the bypass valve closes completely. <br /> No additional liquid can flow into the Advantages of Overfill <br /> tank until the level drops below a reset <br /> point. Prevention Compared to <br /> Models of the 61SO are available to Overfill Warning Systems: <br /> yet virtually any UST application ♦Completely Automatic Operation- <br /> including two point,coaxial,poppeted Does not rely on the alertness or <br /> coaxial and remote fill.The 61SO-3000 speed of response of the delivery <br /> provides two point overfill protection attendant, for certainty of overfill <br /> for 3" riser pipes,and the 61SO-1000 prevention. <br /> and 6150-100C(CARB)feature a ♦Keeps The Top Of UST"Dry,"Per <br /> grooved tube design for use with tank EPA Requirements-Eliminating <br /> gauging systems.Methanol and CARB possible leaks at loose bung fittings <br /> v aoor tight)approved models are also and the need for double containment <br /> :able.The OPW 61SO is approved on vent lines. <br /> o) the New York City Fire Department. ♦Does Not Rely On Pressure In The <br /> (Approval#4902). UST To Stop Flow-Allowing faster <br /> fill times and reducing spill risk. <br /> NOTE: The OPW 61 SO is designed •Speeds Delivery Operations- <br /> `or use on tight fill gravity drop appli- Product flows unimpeded into the <br /> ations only. Do not use for pressure tank until the hose"kick"that <br /> 11 applications. accompanies the valve shut-off <br /> provides a clear signal that the liquid <br /> has reached the shut-off level. <br /> ♦Simple And Inexpensive Installation- *Test witnessed by Bowser-Morner, <br /> In both two-point and coaxial fill Inc., an independent laboratory. <br /> applications,no additional excava- Results available upon request. <br /> tion, manholes or vent piping is <br /> required. <br /> 1 Telephone:(513)870.3219*(800)422.1525*Fax:(513)870.9186*(800)411.3191 <br /> WIM <br /> "" ©1999 OPW Fueling Components*P.O.Box 405003*Gndnnati,Ohio 45240.5003*Printed in USA*TE61SOF•2/99 <br />