17 March 2020 <br />Project No. 14-3002 <br />Page 2 of 5 <br />Coast Guard and U.S. Environmental Protection Agency, 1985). Prior to mobilization, <br />each proposed boring location will be clearly marked, and a utility clearance obtained <br />through Underground Service Alert. <br /> <br /> <br />SURFACE SAMPLE COLLECTION <br /> <br />AGI proposes to collect one (1) additional surface sample in the former power plant area <br />and nine (9) surface samples around the outside perimeter of the former power plant area <br />to evaluate PCB impact. Surface samples will be collected between the surface and three <br />inches below surface grade (bsg) in the following locations: <br /> <br /> One sample will be collected beneath the former natural gas main located in the <br />northeast corner of the power plant area. <br /> Three samples will be collected in the field located to the north of the power plant <br />area between the subject property and 500 East Louise Avenue. <br /> Four samples will be collected in the stormwater basin to the south of the power <br />plant. Samples will be collected beneath the drainpipe outlets and at the toe of the <br />berm in the northwest corner of the basin. <br /> Two samples will be collected between the berm and the power plant along the <br />west side of the facility. One sample will be collected from discolored soil observed <br />in this location during the 05 February 2020 site meeting. <br /> <br />Proposed surface sample locations are illustrated in Figure 3. <br /> <br />Surface samples will be collected using a small shovel or trowel. Soil encountered will be <br />visually classified by AGI personnel in accordance with the USCS. Surface samples will <br />be hand-packed into precleaned and certified 4-oz, Teflon-lined closure, wide-mouth clear <br />glass sample containers (sample jars). Sample jars will be labeled with sample location, <br />depth, time, date and sampler's initials and then placed in a container with sufficient ice <br />and transported under chain-of-custody procedure to a California Environmental <br />Laboratory Accreditation Program (ELAP)-certified laboratory. <br /> <br /> <br />SOIL BORING ADVANCEMENT AND SAMPLING <br /> <br />AGI proposes to advance an additional nine (9) soil borings in the former power plant <br />area to evaluate PCB impact. Three (3) borings will be advanced to total depths of 5 feet <br />bsg and six (6) borings will be advanced to total depths of 10 feet bsg. Soil borings will <br />be advanced in the following locations: <br /> <br /> One boring will be advanced to 5 feet bsg in the former control room building.