My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
4400 - Solid Waste Program
>
PR0504201
>
CORRESPONDENCE_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 3:13:44 PM
Creation date
5/24/2022 12:09:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2020
RECORD_ID
PR0504201
PE
4430
FACILITY_ID
FA0000214
FACILITY_NAME
PILKINGTON NORTH AMERICA INC PLANT 10
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330-9739
CURRENT_STATUS
01
SITE_LOCATION
500 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
17 March 2020 <br />Project No. 14-3002 <br />Page 4 of 5 <br />location, depth, time, date and sampler's initials, and then placed in a container with <br />sufficient ice and transported under chain-of-custody procedure to a California ELAP- <br />certified laboratory. The samples will be pulverized at the laboratory to prepare them for <br />analysis. Proposed concrete sample locations are illustrated in Figure 3. <br /> <br /> <br />SURFACE WATER SAMPLE COLLECTION <br /> <br />During the February 2020 site meeting, standing water was observed in the former used <br />oil storage location. A surface water sample will be collected from standing water in this <br />area. The sample will be collected by dipping a 1-liter amber glass sample container in <br />the water. The sample will be labeled with location, time, date and sampler's initials, and <br />then placed in a container with sufficient ice and transported under chain-of-custody <br />procedure to a California ELAP-certified laboratory. The proposed sample location is <br />illustrated in Figure 3. <br /> <br /> <br />SAMPLE ANALYTICAL PROCEDURES <br /> <br />The water sample, surface samples and soil samples collected at 3, 5, and 7 feet bsg will <br />be analyzed by an ELAP-certified laboratory for the following constituents: <br /> <br /> Percent (%) moisture in accordance with ASTM D2216-05 (solid samples only). <br /> PCBs (dry weight) in accordance with EPA SW-846 Method 8082A; Arochlor 1268 <br />will be added to the list of congeners analyzed for PCBs. <br /> <br />Soil samples collected at 10 feet bsg will be held at the laboratory for potential PCB <br />analysis, if necessary. Soil samples collected at 10 feet bsg will be analyzed if PCBs are <br />detected in the 7-foot samples. The hold time for PCB analysis in soil samples is 14 days. <br /> <br />To clarify further, all surface samples and soil samples collected at 3, 5, and 7 feet bsg <br />will be analyzed for PCBs; the 10-foot samples will be analyzed if PCBs are detected in <br />the 7-foot samples. Soil samples collected at 5, 10, 15, and 20 feet bsg from the 15 <br />borings proposed in the Revised Additional Site Assessment Work Plan will be analyzed <br />for TPH. <br /> <br />Laboratory reports for analyses, testing methods and laboratory quality assurance/quality <br />control (QA/QC), and sample chain of custody documentation will be presented in a report <br />with findings and recommendations. <br /> <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.