Laserfiche WebLink
Ag DW REMOTE FILL 16 <br /> SUMP FACTORY UNISTRUCT <br /> RISER SUPPORT <br /> SWIVEL VAPOR G 23 24 10 FIBRE-LITE FILL - SPILL J 00 Lo <br /> ADAPTER & CAP T5-2 CONTAINMENT MANHOLE W/5 GALLON SPILL BUCKETS Q <br /> W <br /> SUMP SENSOR 31 0Q <br /> 71 1 " BONDED <br /> NEW 4" STAINLESS STEEL j FITTING (TYP.) [LO J <br /> PIPING FITTING ELBOWS j CONDUIT >o w <br /> m ZCC <br /> O c3 <br /> TEE, UNION, NIPPLE FOR " Q <br /> 30 1 <br /> CA H Z L0 <br /> REMOTE VAPOR BY G.C. VAPOR RISER J Q J (3) LL <br /> SWIVEL FILL 13 14 I <br /> ADAPTER & CAP 26 MINI HYDROSTATIC LL Q Z U Z <br /> SENSOR o CD F_ Q J <br /> 4" UNION FITTING (TYP.) > _ W � af> - O <br /> Z cp <br /> 4" MALE TERMINATION FILL RISER o o Q Q <br /> FITTING TYP. 138 - - -- - - -- --- ----- ---------------- � o c O <br /> (TYP.) i a_ 0- z O <br /> W 0 <br /> FF <br /> - - ------ ------------- ------ <br /> T5-2 - - --- --- T5-2 <br /> F <br /> I 03 <br /> 0 0 0 0 <br /> z O <br /> PRIMARY COUPLING (TYP.) 141 136 5x4 TEST REDUCER FITTING m m m Q U <br /> m <br /> G (TYP.) <br /> 76 4" ELECTROFUSION FIBERGLASSC"i �_ <br /> —� <br /> i ! ENTRY BOOT (TYP.) �f N <br /> ! <br /> H <br /> 4" COAXIAL "UPP" REMOTE 139 139 4" COAXIAL "UPP" REMOTE Z <br /> FILL VAPOR PIPING (TYP.) FILL PRODUCT PIPING (TYP.) <br /> ! <br /> ! <br /> a Plan View - Remote Fill (Tank #1-4) D NOT USED G NOT USED <br /> T5-2 SCALE: 1 "= l '-O" <br /> �T5-�2SCALE: NONE �T�5-2SCALE: NONE <br /> DUAL POINT FILL - SPILL 10 10" ABSOLUTE MIN. <br /> CONTAINMENT MANHOLE W/ (2) DISTANCE TO TOP EDGE <br /> 5 GALLON SPILL BUCKETS 18" TYP. OF SUMP NECK <br /> 2" CROWN <br /> Nu <br /> J N <br /> Q <br /> cn > OD <br /> 77 <br /> a W � 0) <br /> r, � <br /> pQ <br /> d a <br /> = w <br /> d <br /> _ 9 pJQ <br /> d <br /> 0 0) 0 <br /> 26 <br /> MINI HYDROSTATIC C1) Q <br /> SENSOR 0 ( <br /> U — <br /> UNISTRUT SUPPORT <br /> BRACKET <br /> 4" COAXIAL "UPP" 139 <br /> PIPING (TYP.) <br /> O <br /> LL <br /> 71 1 " BONDED FITTING <br /> (TYP.) <br /> SUMP SENSOR 31 16 DW REMOTE FILL SUMP <br /> NEW 4" STAINLESS STEEL PIPING <br /> FITTING ELBOWS, TEE, UNION, NIPPLE <br /> FOR REMOTE FILL/VAPOR BY G.C. <br /> B Elevation - Remote Fill (Tank #1-4) ('E_'*'� NOT USED ('H_'� NOT USED °;°;2022 <br /> 1aHE5[OVE7 GROUP,IH[, 7:36:15 AM <br /> T5-2 SCALE: 1 "=l '-O" T5-2 SCALE: NONE T5-2 SCALE: NONE FEsslp <br /> �= HAL P. GRUBB ?� <br /> Sheet Notes J 67814 70 <br /> 1 • - PIPE & CONDUIT PENETRATIONS: NP <br /> C / vALL PENETRATIONS OF THE TANK SUMPS SHALL BE SEALED WITH DOUBLE BULKHEAD FITTINGS SHALL BE INSTALLED PERPENDICULAR TO SUMP WALL TO 9TF OF CA �� <br /> ENSURE THE PROPER INSTALLATION OF ALL BULKHEAD FITTINGS AND RESULTANT WATER TIGHTNESS. ALL PIPING, CONDUIT AND GROUNDS THAT PENETRATE 05/27/22 <br /> THE SUMP SIDE WALLS MUST BE SEALED IN SUMPS. SUMPS SHALL BE HYDROSTATICALLY TESTED WITH STANDING WATER FOR A PERIOD OF 24 HOURS TO <br /> FIBRE-LITE FILL - SPILL 10 INSURE THAT THE SUMPS ARE WATERTIGHT. <br /> CONTAINMENT MANHOLE W/ 5 2' N Z Z <br /> - PIPING TESTING: <br /> GALLON SPILL BUCKETS TESTING OF THE SECONDARY CONTAINMENT PIPING IS REQUIRED. THE CONTAINMENT TERMINATION FITTING IN THE SUMP IS TO BE INSTALLED WITH THE <br /> VALVE TURNED DOWN. THE PIPING IS TO BE CONTINUOUSLY MONITORED BY VACUUM, PRESSURE OR HYDROSTATIC. THEREFORE THE VALVE UNLESS BEING <br /> SWIVEL VAPOR ADAPTER & 24 23 14 13 SWIVEL FILL ADAPTER TESTED SHOULD REMAIN CLOSED. <br /> 2" CROWN CAP (TYP.) 8c CAP (TYP.) 3. - SUMP SENSORS: 0 oN X <br /> SENSOR TO BE MOUNTED AT SIDE OF TANK WHERE VENT/VAPOR PIPING PENETRATES INTO THE SUMP IS MADE AND BELOW LOWEST m <br /> d PENETRATION FITTING WITHIN SUMP AREA. MOUNT SENSOR FLUSH TO LOWEST POINT IN SUMP BOTTOM. ALL TANK SUMP SENSORS SHALL BE 3 o <br /> a NON-DISCRIMINATING AND POSITION SENSITIVE. a o m <br /> 0 o v a o <br /> a Q d °a <br /> 4. - FILL AND VAPOR CAP HEIGHT TO GRADE: <br /> �o a THIS DIMENSION IS CRITICAL AND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK <br /> a a <br /> CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. <br /> U <br /> °a < 5. - DROP TUBE CRITICAL DIMENSION: p �' <br /> d _T. THIS DIMENSION IS CRITICAL AND MUST BE ADHERED TO. CONTRACTOR WILL BE REQUIRED TO REINSTALL AT OWN EXPENSE OR WILL BE BACK — v <br /> -1 CHARGED FOR EXPENSE TO CORRECT INCONSISTENCIES. <br /> U) o <br /> a p 6. - MANHOLE CROWNS: Q� 3 <br /> ALL MANHOLE OPENINGS ON THE TANK SLAB SHALL BE INSTALLED WITH A 2" X 18" RUN CROWN OF CONCRETE TO PREVENT WATER INTRUSION C = o <br /> Zwmma. INTO THE MANHOLE. 0 Im <br /> UNISTRUT SUPPORT BRACKET 7• - U.G. CONDUIT: <br /> ALL U.G. CONDUIT TO TANK SUMPS SHALL BE ROBROY RIGID STEEL PVC COATED SCHEDULE 40 (NO SUBSTITUTIONS). CONDUIT MINIMUM BURY LU <br /> " DEPTH IS 24 PER CODE. ALL JUNCTION BOXES SHALL BE CLASS 1 DIV. 2 RATED. ALL ELECTRICAL CONDUIT IN SUMPS SHALL INCLUDE A M <br /> 4 STAINLESS STEEL ° � � � � , <br /> RISERS (TYP.) °° SEAL-OFF ENTERING AND LEAVING. SEAL-OFFS SHALL BE INSTALLED 6" MIN. ABOVE HIGHEST PENETRATION IN SUMP. Q rn N o <br /> 8. - FILL & VAPOR RISER GROUNDING: m '' c: Q r <br /> 1 " BONDED FITTING (TYP.) 71 ALL FILL AND VAPOR RISERS SHALL BE GROUNDED TO PREVENT STATIC DISCHARGE. SEE DETAIL E ON SHEET E-4 FOR RISER GROUNDING DETAIL. t N r <br /> • 9. - STAINLESS STEEL FITTINGS: C �n +-� N L0 <br /> - CONTRACTOR TO PROVIDE ALL MISCELLANEOUS NPT FITTINGS AND NIPPLES FOR CONNECTIONS TO TURBINES, SIPHON SYSTEM m 0 Y o <br /> SUMP SENSOR 31 m AND VAPOR RECOVERY SYSTEM. ALL STAINLESS STEEL FITTINGS SHALL BE MANUFACTURED BY "STANDARD PIPE PRODUCTS" r o <br /> 139 4" COAXIAL "UPP" OR EQUAL SPECIFICATIONS AS FOLLOWS: 0 <br /> PIPING (TYP.) S.S. FITTINGS DIMENSIONS MATERIAL THREAD PRESSURE RATING <br /> DW REMOTE FILL SUMP 16 w <br /> 76 BONDED FITTING (TYP.) (TEES, ELBOWS) <br /> STAINLESS STEEL PIPING FITTING <br /> CLASS 150/PN 20 ASME B16.3 ASTM A- 182 ASME B. 1 20. 1 ASME B16.3 N <br /> NEW 4 <br /> ELBOWS, TEE, UNION, NIPPLE FOR S.S. UNIONS <br /> REMOTE FILL/VAPOR BY G.C. (TYP.) CLASS 150/PN 20 ASME B16.39 ASTM A- 182 ASME B. 1 20. 1 ASME B16.3 <br /> S.S. PIPE <br /> E <br /> c Section - Remote Fil (Tank #1-4) CLASS 150/PN 20 ASTM A733 ASTM A-312 ASME B. 1 20. 1 ASME B16.3 Ln <br /> CD <br /> 10. - CORROSION PROOF: 0 CD <br /> T5-2 SCALE: 1 "=l '-O" ALL TURBINE PUMP HEADS TO HAVE ADVANCED CORROSION PROOF PROTECTION WITH E-COATED FINISH. cv o <br /> F NOT USED z O <br /> T5-2 <br /> O N <br /> SCALE: NONE 3 ~ <br />