REST ROOM NOTES 0 <br /> W <br /> DISPENSER 1. REST ROOMS MUST COMPLY WITH ALL BUILDING (FEDERAL, STATE, <br /> II II 24 AND LOCAL) FIRE, AND HEALTH DEPARTMENT CODES. ADA ^� <br /> '.-PARTITION -PARTITIO REQUIREMENTS MUST ALSO BE MET IN BOTH RESTROOMS. <br /> II II 2. HOT WATER ACCESS IS REQUIRED AT ALL REST ROOM SINKS AND <br /> MOP SINKS. roup <br /> �j 39" - 41" II <br /> 3. PROVIDE AND INSTALL 3' X 2' MIRRORS IN REST ROOMS ABOVE Architects <br /> k MIRROR LAVATORY. <br /> I II W/ FRAME MIRROR 4. CONTRACTOR TO INSTALL SOAP DISPENSERS, PAPER TOWEL HOLDER, 16821 SE MCGILLIVRAY BLVD, <br /> I54" MIN 36" MIN, TOILET PAPER HOLDERS, DOOR CLOSERS AND EXHAUST FANS IN ALL STE 108 <br /> I zPh. 360 <br /> DOOR STOP 18' MIN � } <br /> 2" MIN. 24" MIN. ( RESTROOMS. VANCOUVER, WA 98683 <br /> 18" 5. INSTALL NEW TOILET PARTITIONS AS NEEDED. 834-6536 <br /> DIAPER CHANCE II � 42 MIN. SAX ( <br /> _ II II <br /> I S.S. GRAB BAR k 6. SEE SHEET A4.0 FOR RESTROOM ACCESSORIES FIXTURE SCHEDULE. e-mail: kmccrackenC�pmdginc.com <br /> I 2 ROLL TOILET II <br /> I T[SSU� HOLDER �I Ken McCracken,Architect <br /> -9 >< <br /> I ® I I Q <C INSULATE <br /> z z AROUND <br /> BASE PER FINISH I BASE PER FINISH PIPES <br /> SCHEDULE, TYP. I SCHEDULE, TYP. i� ''' rn "' 6' <br /> II �r GRAB BAR NOTES C <br /> A CIF0 <br /> 36" MAX. PAPER TOWEL 6" g" <br /> HOLDER 1. LOCATE CRAB BARS, ONE SIDE AND ONE BACK OF TOILET, 33" `> <br /> MENS ELEVATION 'A' MENS ELEVATION MENS ELEVATION C A MIN. MENS ELEVATION 'D' ABOVE AND PARALLEL TO THE FLOOR, EXCEPT WITH A TANK-TYPE KENNETH <br /> 17" MIN. TOILET WHICH OBSTRUCTS PLACEMENT, THE GRAB BAR MAY BE AS <br /> HIGH AS 36". DIAMETER OF GRAB BAR IS 1 1/4" TO 1 1/2", OR MCCRACKEN <br /> SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" SCALE. 1/2"=1'-0" SHAPE PROVIDES AN EQUIVALENT GRIPPING SURFACE. C-32095 <br /> 2. IF GRAB BARS ARE MOUNTED ADJACENT TO WALL, THE SPACE 'pe <br /> SOAP <br /> BETWEEN WALL AND BAR IS TO BE 1 1/2". </0 h�war:bid° <br /> I) DISPENSER 24„ II 3. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. �NSEDARCN� <br /> II'.PARTITION - II ,�RTITION <br /> 4. GRAB BARS AND ANY SURFACE ADJACENT TO THEM CANNOT HAVE <br /> II II ANY SHARP OR ABRASIVE ELEMENTS. EDGES ARE TO HAVE A <br /> II II lI MINIMUM RADIUS OF 1/8". <br /> 11 11 I 39 - 41" 5. GRAB BAR CAPACITY SHALL BE A MINIMUM 250 POUNDS. <br /> 11 11 I <br /> II II LOMIRROR MIRRORII <br /> 36" MIN. II II ``3 W/ FRAME I 54" MIN <br /> PAPER T I <br /> 12" MIN. 42 24" MIN. II II HOLDER DIAPER CHANGE _ ' MIN. 12" <br /> II II 18' DOOR STOP I <br /> 18" II II MIN lI � MAX. <br /> II LU <br /> //_2 <br /> j' II R LL DLE ACCESSORIES NOTES TISSUE HOLDER T <br /> II II II t <br /> I I � z z INSULATE AROUND BASE PER 1. WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES AND <br /> ® ® PIPES ¢ FINISH I SIMILAR DISPENSERS AND DISPOSAL FIXTURES ARE PROVIDED, AT W <br /> rn SCHEDULE, I LEAST ONE OF EACH TYPE IS TO BE LOCATED WITH ALL OPERABLE r ♦ <br /> III II "J " " Z J TYP. i PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM THE FLOOR. 2 V <br /> a, MINIMUM 30"x48" CLEAR FLOOR SPACE TO ALLOW FORWARD OR O <br /> 4 7T PARALLEL APPROACH TO ACCESSORIES. <br /> �6" 8" 36" MAX. 2. MOUNT MIRRORS WITH BOTTOM EDGE NO MORE THAN 40" FROM W <br /> AXJ MIN. FLOOR. Q <br /> WOMENS ELEVATION 'A' 17" MIN. WOMENS ELEVATION 'B' WOMENS ELEVATION 'C' WOMENS ELEVATION 'D' 3 LOCATE TOILET TISSUE DISPENSER ON WALL WITHIN 12" OF FRONT LUJI <br /> L <br /> EDGE OF TOILET SEAT. m <br /> U. <br /> SCALE: 1/2"=l'-O" SCALE: 1/2"=l'-O" SCALE. 1/2"=l'-O" SCALE: 1/2"=I'-O" �W/ <br /> 18" MIN. 18" MIN. n_ f.L <br /> PLUMBING FIXTURE SCHEDULE <br /> z FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.6 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET, FLUSH TANK WITH 12" ROUGH-IN. LAVATORY NOTES w <br /> 17" - 19" AMERICAN STANDARD CHAMPION 4 RIGHT HEIGHT #2002.014 OR EQUAL. PROVIDE SUPPLY & STOP. PROVIDE OPEN FRONT SEAT. AMERICAN STANDARD #5901,100 OR a o <br /> a F 1 EQUAL (NOTE: TRIP SHALL BE ON WIDE SIDE OF WATER CLOSET). <br /> r � <br /> I0 PROVIDE A CLEAR SPACE 30"x48" MIN. IN FRONT OF THE � <br /> LAVATORY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE <br /> I I w <br /> 20"X18" WALL HUNG ADA LAVATORY W/ FRONT OVERFLOW, CONCEALED HANGERS & 4„ CENTERS. AMERICAN STANDARD LUCERNE #0355.012 OR EQUAL. FAUCET SHALL BE SPACE UNDER LAVATORY. < a a <br /> ,< POLISHED CHROME-PLATED CAST BRASS BODY WITH 4" SPOUT, 4" BRASS WRIST BLADE, 0.5 GPM SPRAY AND POP-UP DRAIN. AMERICAN STANDARD MONTERREY <br /> r 2, INSULATE OR CONFIGURE HOT WATER SUPPLY AND DRAIN PIPING <br /> #5501.170 WITH #V05 AERATOR 0R EQUAL. INSULATE EXPOSED DRAIN & WATER PIPES WITH TRUEBRO LAV GUARD KIT #102 E-Z. UNDER LAVATORIES TO PREVENT CONTACT. <br /> 00 I CLEAR FLOOR I ( z <br /> SPACE FOR 00 CLEAR FLOOR CO m n 24" X 24" MOLDED STONE MOP SERVICE BASIN, WITH 3' DRAIN. FIAT #MSB-2424 OR EQUAL. PROVIDE SERVICE FAUCET WITH PAIL HOOK & INTEGRAL VACUUM BREAKER, 3. NO SHARP OR ABRASIVE ELEMENTS ARE ALLOWED UNDER <br /> z LAVATORIES. <br /> I LAVATORY I SPACE FOR ;_ "' MOP BRACKET, FLAT STAINLESS STEEL. STRAINER AND HOSE & BRACKET. FIAT #830 AA, 889 CC, 1453 BB & 832 AA OR EQUAL. <br /> FIXTURE I DRINKING I `� 4. FAUCET CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO J <br /> z BE OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING, <br /> I I FOUNTAIN I INSTALL NEW 10 & 20 GALLON WATER HEATER AS NOTED ON PLAN. SEE PLUMBING DRAWINGS FOR SPECIFICATIONS. PINCHING. OR TWISTING OF WRIST. THE FORCE REQUIRED TO <br /> L <br /> - ACTIVATE CONTROLS IS NOT TO EXCEED 5 LBS. LEVER OPERATED, <br /> __ I PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE <br /> TWO--STATION, WALL MOUNTED, ELECTRIC DRINKING FOUNTAIN, BARRIER-FREE ACCESS (ADA}, FRONT ONLY EASY TOUCH CONTROL, HIGH UNIT ON RIGHT, ELKAY EXAMPLES of ACCEPTABLE DESIGN. <br /> 30" MIN. - - #EZTLRDDC OR EQUAL. PROVIDE SUPPLY, STOP VALVE & TRAP. PROVIDE CANE APRON AS REQUIRED. <br /> 45" MIN, 8" 6, FURNISH AND INSTALL GREASE TRAP AS REQUIRED BY CODES. FURNISH AND INSTALL TRENCHING FOR FLOOR DRAINS AS REQUIRED BY CODES. 5. FOR AT CLOSING <br /> T VOL SECONRDS ALLOWED IF THE FAUCET REMAINS OPEN W Z Cf) ug <br /> "' (- <br /> ACCESSIBLE CLEARANCES SHUT-OFF VALVE ZURN 75751 WALL HUNG URINAL (3/4") WITH ZURN Z6003AV-ULF 1/8 GALLON-PER-FLUSH FLUSH VALVE AND ZURN Z-1222 PLATE TYPE SYSTEM URINAL CARRIER WITH URINAL NOTES W W Z � <br /> VACUUM BREAKER BEARING PLATE. COLOR WHITE. MOUNT AT ADA COMPLIANT HEIGHT. �R ` a ,Q <br /> C.W. MAKE-UP TOILET PARTITIONS AND URINAL SCREEN: FLOOR MOUNTED, OVERHEAD BRACED TOILET PARTITIONS, AND 24" URINAL SCREEN. COORDINATE WITH PM PRIOR TO ORDERING. <br /> SCALE: NOT TO SCALE v AML v <br /> r ' <br /> H.W. TO FIXTURES COLOR TO BE DETERMINED. f r <br /> THERMAL EXPANSION TANK SIZE PER <br /> MFG. RECOMMENDATIONS. 1_ PROVIDE STALL--TYPE OR WALL HUNG URINALS WITH AN ELONGATED a z <br /> RIM AT MAXIMUM HEIGHT 17". FLUSH CONTROLS TO BE HAND O <br /> OPERATED AND MEET SAME REQUIREMENTS AS FLUSH CONTROLS OF <br /> 5'-0" MIN. 5'-D" MIN. 18 18" TOILET AND TO BE NO MORE THAN 44" ABOVE FLOOR. N <br /> IDENTIEICATION TITLE 24 SIGN ADA SIGN 6 3/4„ 36" GRAB BAR 36" GRAB BAR 2 ALTHOUGH NOT EMPHASIZED IN REGULATIONS THE ACCESSIBLE <br /> SYMBOL (FOR WALL HUNG URINAL SHOULD BE MAXIMUM ELbNGATED RIM TYPE IF O <br /> PROVIDE DISCONNECT OR DISCONNECTION AVAILABLE. <br /> CALIFORNIA 1/4' THICK MEANS PER CODE REQUIREMENTS. N <br /> 3' TITLE 24 ONLY) SIGN NEW TEMPERATURE AND _ 32" MIN. 32" MIN, 3. WHERE URINALS ARE PROVIDED AT LEAST ONE SHALL HAVE A <br /> 30"x48" MIN. CLEAR SPACE IN FRONT OF URINAL. <br /> WATER HEATER PRESSURE RELIEF VALVE. ` Z 42" MIN. z 42" MIN. <br /> DISCHARGE FULL SIZE OF VALVE DISCHARGE w / <br /> PIPE TO MOPSINK OR FLOOR DRAIN AND I 0" MIN. N N <br /> TERMINATE NTH ELBOW TURNED DOWN. �" �� �, Z o U) N u7 cV <br /> z DIAMETER 30"x48- 5t a 32" MIN. <br /> MEN CLEAR / SCLEAR LL"'PACE J CLEAR z Q <br /> HOSE BIBB / <br /> GRADE <br /> 4 DEEP GALVANIZED. DRAIN PAN � \ -J� Q <br /> co <br /> INSTALL WATER HEATER ABOVE MOP SINK UPON 8" 20 <br /> �GA. STEEL STUD JOISTS SPACED TL O.G. SPANNING - - CDR' 60" MIN. DRINKING FOUNTAIN NOTES T <br /> ADA ROOM SURROUNDING WALLS. COORDINATE STRUCTURAL 32" MIN. °� <br /> r IDENTIFICATION SUPPORT FRAMING WITH GENERAL CONTRACTOR. p Z J <br /> 1" DRAIN LINE. ROUTE TO MOPSINK OR N CLEAR // <br /> SIGN TURNED DAWN AND TERMINATE WITH ELBOW % 6D"X60" <br /> LEVEL AND _ 24"MIN. 1 32"MIN 1. DRINKING FOUNTAINS ARE TO BE LOCATED WITHIN ALCOVES OR <br /> _ _ WOMEN * * * CLEAR POSITIONED SO AS NOT TO BE IN CORRIDOR OR WALK. <br /> `p L STRIKE SIDE OF Z z ~� �` 2_ WHEN ENFORCING AGENCY ALLOWS AN UNREASONABLE HARDSHIP, <br /> DOOR 8 0 - FOUNTAINS MAY BE LOCATED IN PATH OF TRAVEL BUT MUST HAVE <br /> 1 4" THICK - -- \ co A TEXTURED AREA FOR 1 FOOT AROUND FOUNTAIN, OR WING WALL <br /> SIGNS a FLUSH ACTIVATOR ON WILL BE REQUIRED ON EACH SIDE OF FOUNTAIN. <br /> PROVIDE AND INSTALL WALL MTD. „ <br /> CD <br /> MOP HOLDER 50 MOPS ALWAYS 18 WIDE SIDE _ I <br /> AREA FOR DRIP INTO MOP SINK. 3. THE BUBBLER CAN BE ACTIVATED BY HAND OPERATED LEVER WITHIN Project Number <br /> HARDWARE MULTIPLE ACCOMMODATION ROOMS 6" OF THE FRONT, PUSH BAR ALONG FRONT OR BY ANOTHER <br /> INSTALL FRP TO 48' A.F.F. APPROVED CONTROL EASILY OPERATED BY A PERSON WITH ry���-++�/� <br /> . . . ON TWO WALLS. FRONT APPROACH SIDE APPROACH DISABILITIES. THE TEXTURED SURFACE IS TO BE CLEARLY DGM1 1006.Q <br /> TOILET ROOM NOTES: IDENTIFIABLE BY A BLIND PERSON USING A CANE. <br /> UNISEX ,,, 2. CLEAR OPENING WIDTH OF 32" IF LOCATED AT THE END. 34" IF LOCATED AT 510E OF 4• WATER STREAM IS TO BE PARALLEL TO THE FRONT SIDE OF Sheet Name <br /> 1. CLEAR ACCESS A MIN. CF 44 IN WIDTH THROUGHOUT SANITARY FACILITY TO REACH COMPARTMENT. FOUNTAIN. <br /> SEE SHEET AI.1FOR OTHER ITEMS THE HANDICAPPED COMPARTMENT. (48" CLEAR @HINGE 510E APPROACH TO <br /> TO <br /> NOTES TO BE INSTALLED IN THIS AREA. COMPARTMENT). 3, COMPARTMENT DOOR PROVIDES MINIMUM 9" CLEARANCE FOR FOOTRESTS UNDERNEAEI-1 5, IN EXISTING BUILDING AND FACILITIES WHERE UNREASONABLE 2. THERE MUST BE A CLEAR SPACE OF SUFFICIENT SIZE TO INSCRIBE A 60" DIA, CIRCLE DOOR. HARDSHIP IS GRANTED, THE EXISTING FOUNTAINS MAY REMAIN. REST ROOM <br /> 1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. WITHIN THE SANITARY FACILITY ROOM AT A HEIGHT OF 27" A.F.E. DOORS OTHER THAN 4. INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR IS EOUiFPED WITH A LOOP OR HOWEVER, THE TEXTURED SURFACE OR WING WALLS WILL BE <br /> 2. DENTIFICATION SYMBOLS ARE TO BE CENTERED ON DOOR 60" ABOVE FLOOR AND THE TOILET COMPARTMENT DOOR MAY NOT ENCROACH MORE THAN 12 INTO CIRCLE. U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH IS A FLIP-OVER REQUIRED, DETAILSSTYLE, SLIDING, OR OTHER HARDWARE NOT REQUIRING TIGHT GRASPING OR TWISTING. <br /> ARE TO BE DISTINCTLY DIFFERENT FROM THE DOOR IN COLOR AND CONTRAST. I 3, WHERE 6 OR MORE STALLS ARE PROVIDED; 1 SHALL BE SfDE TRANSFER STALL AS <br /> ( � . ., 5. OPENING HARDWARE IS CENTERED BETWEEN 30' AND 44' ABOVE FINISH FLOOR. 6. A STANDARD HEIGHT DRINKING FOUNTAIN MUST BE PROVIDED WITH <br /> 3. BOTH TITLE 24 SIGNS AND ADR SIGNS ARE REQUIRED IN CALIFORNIA. SHOWN, AND 1 SHALL BE A 36" WIDE SEMI-AMBULATORY STALL 6. DOOR MAY SWING IN OR OUT. COMPLY WITH CLEAR SPACE REQUIREMENT FOR ALL AN ACCESSIBLE ONE. <br /> 4. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR. MOP SINK DOORS. <br /> 5, LETTERS & NUMBERS ON SIGNS SHALL BE RAISED 1/32" MIN., SHALL BE A MIN, OF HANDICAPPED COMPARTMENT DOOR: INTERIOR COMPARTMENT: <br /> 5/8" HIGH, A MAX. OF 2" HIGH, & SHALL BE SANS-SERIF UPPERCASE 1. EQUIPPED WITH AN AUTOMATIC CLOSING DEVICE (3 SECOND MINIMUM SWEEP TIMI FROM 1. FLUSH VALVE IS ON WIDE SIDE OF TOILET AREA. <br /> CHARACTERS ACCOMPANIED BY CONTRACTED GRADE 2 BRAILLE. OPEN POSITION OF 70 DEGREES TO A POINT 3" FROM THE LATCH). 2. 44" MAXIMUM FROM FLOOR TO FLUSH VALVE. <br /> Sheet Number <br /> 3. 5 LBS. MAXIMUM FORCE TO OPERATE VALVE. <br /> RESTROOM DOOR SIGNAGE W.H./MOP SINK DETAIL TOILET ROOMS 4. SEE 3/AD.2 FOR HEIGHTS OF GRAB BARS AND <br /> ACCESSORIES. <br /> SCALE: NOT TO SCALE NOT TO SCALE SCALE: 1/4"=1'-O" A5 -w0 <br /> REFERENCE SHEET <br />