30 June 2022 AdvancedGeo <br /> Project No. 22-6900 An Employee-Owned Company <br /> Page 4 of 15 <br /> leach lines, and four 42-inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 21470 Rose Clover Lane <br /> LOCATION: Adjacent property to east <br /> SEPTIC SYSTEM: 1) Permit date November 2011; new installation of septic system: <br /> 1,200-gallon concrete tank with two compartments, distribution box (D-Box), three 40- <br /> foot-long leach lines, and three 36-inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 606 South Reid Avenue <br /> LOCATION: Adjacent property to North <br /> SEPTIC SYSTEM: 1) Permit date May 1971; new installation of septic system: 1,200- <br /> gallon precast concrete tank with two compartments, distribution box (D-Box), two 50- <br /> foot-long leach lines, and one 36-inch diameter, 25-foot-deep seepage pit. <br /> ADDRESS: 617 South Reid Avenue <br /> LOCATION: Approximately 200 feet to northwest <br /> SEPTIC SYSTEM: 1) Permit date September 2007; new installation of septic system: <br /> 1,500-gallon concrete tank with two compartments, distribution box (D-Box), three 40- <br /> foot-long leach lines, and three 36-inch diameter, 25-foot-deep seepage pits. <br /> ADDRESS: 21477 Rose Clover Lane <br /> LOCATION: Approximately 250 feet to east <br /> SEPTIC SYSTEM: 1) Permit date November 2011; new installation of septic system: <br /> 1,200-gallon concrete tank with two compartments, distribution box (D-Box), three 40- <br /> foot-long leach lines, and three 36-inch diameter, 25-foot-deep seepage pits. <br /> 3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE <br /> The current residence on the property has three (3) bedrooms and utilizes the existing <br /> septic system 365 days per year. The existing septic system will not be altered from the <br /> current configuration. The average and reasonable maximum usage of wastewater for a <br /> three-bedroom home by residents is 100 gallons per day (gpd) for the first bedroom and <br /> 50 gpd for each additional bedroom for a total of 200 gpd. <br /> The new proposed septic system is planned to be located in the northeastern portion of <br /> the property over 100 feet away from the existing onsite domestic water well and the <br /> surrounding water wells. The proposed septic system will service the planned three- <br /> bedroom modular home to be developed on the property. The proposed septic system <br /> will be used by the three-bedroom residence 365 days per year. The average and <br /> reasonable maximum usage of wastewater for a three-bedroom home by residents is <br /> 100 gpd for the first bedroom and 50 gpd for each additional bedroom for a total of <br /> 200 gpd. <br />