My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002397
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICKE GROVE
>
11793
>
2600 - Land Use Program
>
UP-90-05
>
SU0002397
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2022 4:17:52 PM
Creation date
7/7/2022 9:51:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0002397
PE
2626
FACILITY_NAME
UP-90-05
STREET_NUMBER
11793
STREET_NAME
MICKE GROVE
STREET_TYPE
RD
City
LODI
ENTERED_DATE
10/26/2001 12:00:00 AM
SITE_LOCATION
11793 MICKE GROVE RD
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11312 Submersible Wastewater Pumps and Accessories <br /> and letting stand. After 24 hours, the tank shall be refilled to the soffit and the <br /> exfiltration rate shall be determined by measuring the water loss during the next two <br /> (2) hours. Any leakage shall be cause for rejection. After installation is completed and <br /> before backfilling, each tank shall be filled with water to a point 2" above the top of <br /> the tank and the water loss measured after a twenty four-hour period. After it has been <br /> determined that there is no leakage, test the access riser seam. Backfill to a minimum <br /> depth of 2" above the riser seam to prevent damage from hydrostatic uplift. Fill the <br /> tank to a point 2" above the riser seam (the field test period may be reduced to not <br /> less than two (2) hours). No tank will be accepted if there is any leakage over the two <br /> (2) hour period. <br /> B. RISERS & LIDS: <br /> 1. Risers: Risers shall be required for access to internal vaults and access into the septic <br /> tanks for septage pumping. All risers shall be constructed watertight. The risers shall <br /> be attached to the tanks such that a watertight seal is provided. Risers shall extend 3" <br /> above original grade to allow for settlement and to ensure positive drainage away <br /> from the access. Risers for inspection ports shall be a minimum of 18" in nominal <br /> diameter. Risers containing pumping assemblies or electrical splice boxes shall be a <br /> minimum of 24" in diameter and shall be of sufficient diameter to allow removal of <br /> internal vaults without removing splice boxes, etc. Risers shall be a minimum of 30" <br /> in nominal diameter when the depth of bury is 36" or greater. All other risers shall be <br /> a minimum of 24" in nominal diameter and shall vary in height depending on the <br /> depth of bury on the various tanks. Adhesive required to adhere the PVC or fiberglass <br /> risers to either fiberglass or ABS tank adapter shall be a two-part adhesive, Model <br /> MA320, SS115, SS140 or approved equal, or a single component adhesive Model <br /> ADH 100 or approved equal. If backfilling the same day is desired, a combination of <br /> Model MA320 and Model ADH 100 adhesives or approved equals should be used. To <br /> ensure product compatibility, a single manufacturer shall supply risers, lids, and <br /> attachment components. <br /> 2. Inlet Risers: Inlet risers (required only on two-compartment tanks and tanks with <br /> greater than 1500-gallon capacity) shall be Perma-Loc, Ultra-Rib, KOR FLO or <br /> engineer-approved equal. The material shall be PVC as per ASTM D-1784 and tested <br /> in accordance with AASHTO M304M-89. The risers shall be constructed of non- <br /> corrosive material and designed to be buried in soil. Risers shall have a minimum <br /> stiffness of 10 psi, when tested according to ASTM D2412. Risers shall be capable of <br /> withstanding a truck wheel load (54 square inches) of 2500 pounds for 60 minutes <br /> with a maximum vertical deflection of a 1/2 an inch. Risers shall extend to 3 inches <br /> above the ground surface to allow for settlement and shall have a minimum nominal <br /> diameter of 18 inches. <br /> 3. Outlet Risers: Outlet risers shall be Perma-Loc, Ultra-Rib, KOR FLO or engineer- <br /> approved equal. The material shall be PVC as per ASTM D-1784 and tested in <br /> accordance with AASHTO M304M-89. The risers shall be constructed of non- <br /> corrosive material and designed to be buried in soil. Risers shall have a minimum <br /> stiffness of 10 psi, when tested according to ASTM D2412. Risers shall be capable of <br /> withstanding a truck wheel load (54 square inches) of 2500 pounds for 60 minutes <br /> Micke Grove Zoo Wash Water and Septic Disposal System 11312-3 <br /> Siegfried Engineering, Inc. <br /> MESA Project LOCA 0701 <br />
The URL can be used to link to this page
Your browser does not support the video tag.