My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002397
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICKE GROVE
>
11793
>
2600 - Land Use Program
>
UP-90-05
>
SU0002397
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2022 4:17:52 PM
Creation date
7/7/2022 9:51:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0002397
PE
2626
FACILITY_NAME
UP-90-05
STREET_NUMBER
11793
STREET_NAME
MICKE GROVE
STREET_TYPE
RD
City
LODI
ENTERED_DATE
10/26/2001 12:00:00 AM
SITE_LOCATION
11793 MICKE GROVE RD
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11312 Submersible Wastewater Pumps and Accessories <br /> with a maximum vertical deflection of 1/2 an inch. Risers shall be at least 12 inches <br /> high, shall have a minimum nominal diameter of 24 inches for simplex pumping <br /> applications or 30 inches when used in a duplex pumping application and shall be <br /> factory-equipped with the following: <br /> a. Electrical and Discharge Grommets: When applicable, Orenco Systems®, Inc. <br /> EPDM grommets shall be installed by the manufacturer for discharge piping,vent <br /> piping, and/or the electrical conduit to assure a watertight seal. The manufacturer <br /> of the access risers shall install the grommets at the factory. <br /> b. Adhesive: When bonding to concrete or fiberglass grooves, a two-part adhesive, <br /> one pint required per 18" or 24" diameter riser and one quart required per 30" <br /> diameter riser, Model ADHP10 or ADHQ10, or approved equal shall be used. <br /> When bonding to a flanged riser tank adapter, either a two-part adhesive, Model <br /> MA320 or approved equal, or a single component adhesive Model ADH 100 or <br /> approved equal shall be used. <br /> 4. Riser-To-Tank Attachment: Risers shall be attached to tanks with one of the <br /> following attachment systems, or approved equal: (1) Orenco Systems®, Inc. Model <br /> RUBDKIT attachment kit; (2) Orenco Systems, Inc. Model PRTA24 tank adapter <br /> used with Model PRTA24BDKIT bolt down kit, and Model ADH100 and/or MA320 <br /> adhesives; (3) Orenco Systems, Inc. Model RRFTA tank adapter used with Model <br /> RRFTABDKIT bolt down kit and Model ADHP 10 adhesive; (4) Orenco Systems, <br /> Inc. Model PRTA30 tank adapter used with Model PRTA30BDKIT bolt down kit and <br /> Model ADH 100 and/or MA320 adhesives. All attachment components shall be <br /> constructed of waterproof, non-corrosive materials, such as PVC, ABS, fiberglass, or <br /> stainless steel. Adhesives and sealants shall be waterproof, corrosion resistant and <br /> approved for the intended application. The riser-to-tank connection shall be <br /> watertight and structurally sound. The riser-to-tank connection shall be capable of <br /> withstanding a vertical uplift of 5000 pounds to prevent riser separation due to tank <br /> settlement, frost heave, or accidental vehicle traffic over the tank. <br /> 5. Lids: One lid shall be furnished with each access riser. Lids shall be Orenco <br /> Systems®, Inc. Model FL24G-4BU or FL30G or engineer-approved equal, as <br /> appropriate, fiberglass with green non-skid finish, and provided with stainless steel <br /> bolts, and wrench. Manufacturer shall provide evidence that lids have been used <br /> successfully in continuous field service for a minimum of five years to demonstrate <br /> long-term integrity and suitability for the application. Lids shall be waterproof, <br /> corrosion resistant and UV resistant. Lids shall be flat, with no noticeable upward <br /> dome. A crown or dome of no more than 1/8" is allowable. Lids shall not allow water <br /> to pond on them. Lids shall have a green non-skid finish. Self-lubricating plastics, <br /> such as polyethylene, shall not be considered non-skid without addition of a non-skid <br /> coating. Lids shall form a watertight seal with the top of riser. Lids shall be capable of <br /> withstanding a truck wheel load (54 square inches) of 2500 pounds for 60 minutes <br /> with a maximum vertical deflection of 3/4 of an inch. Lids shall be provided with <br /> tamper-resistant stainless steel fasteners and a tool for fastener removal. Tamper- <br /> resistant fasteners include recessed drives, such as hex, Torx, and square. Fasteners <br /> that can be removed with common screwdrivers, such as slotted and Phillips, or <br /> Micke Grove Zoo Wash Water and Septic Disposal System 11312-4 <br /> Siegfried Engineering, Inc. <br /> MESA Project LOCA 0701 <br />
The URL can be used to link to this page
Your browser does not support the video tag.