Laserfiche WebLink
Lennar Homes of California Mountain House Creek, Parcel L, Tract 3424, Tracy <br /> 4943.410.103 Phase I Environmental Site Assessment <br /> 3.3.1.2 Other Properties <br /> The following databases include facilities listed within the appropriate ASTM search distances of <br /> the Property on Environmental Records sources. <br /> TABLE 3.3.1.2-1: Environmental Database Listings for Nearby Properties <br /> I STREET DATABASES <br /> DELTA EXPRESS INC 498 N ORINDA CT RCRA NonGen/NLR <br /> CHEVRON, MTN. HOUSE SITE#1, BYRON RD CPS-SLIC, CERS <br /> MTN. HOUSE <br /> CHEVRON, MTN. HOUSE SITE#2, BYRON RD CPS-SLIC, CERS <br /> MTN. HOUSE <br /> NEIGHBORHOOD E SCHOOL MOUNTAIN HOUSE SCH, ENVIROSTOR <br /> PARKWAY/BYRON ROAD <br /> MOUNTAIN HOUSE WEST BYRON ROAD VCP, ENVIROSTOR <br /> DEVELOPMENT SITE#3 <br /> PROPOSED QUESTA <br /> ELEMENTARY SCHOOL 650 ESPLANADE DRIVE SCH, ENVIROSTOR <br /> (NEIGHBORHOOD H) <br /> NEIGHBORHOOD G SCHOOL KELSO ROAD/BYRON ROAD SCH, ENVIROSTOR <br /> CHEVRON, MTN. HOUSE SITE #1 & #2, MTN. HOUSE (SL0607789794) - 0.21 Mile Northeast <br /> These two closed Cleanup Program Cases are related to the Chevron pipeline that extends <br /> through an easement along the Southern Pacific Railroad line parallel to Byron Road. The cases <br /> were closed on September 25, 2008. The impacts were isolated to a small area, and they included <br /> crude oil spills that impacted soil and groundwater. Site#1 exhibited an impacted area measuring <br /> approximately 200 feet by 150 feet. Site #2 exhibited an impacted area measuring approximately <br /> 100 feet by 75 feet. The crude oil had been at the site for at least 30 years, and the plume was <br /> considered stable or decreasing in size. The plume extends under the Byron Road right-of-way. <br /> Based on the immobility of the weathered crude oil and the proximity to the Property, these cases <br /> are unlikely to pose an environmental risk to the Property. <br /> CHEVRON, MTN. HOUSE SITE #3, MTN. HOUSE (SL0607718672) - 0.56 Mile East <br /> This closed Cleanup Program Case is related to the Chevron pipeline that extends through an <br /> easement along the Southern Pacific Railroad line parallel to Byron Road. DTSC originally <br /> managed the site, but the case was transferred to the Regional Water Quality Control Board <br /> (RWQCB). The case was closed on May 6, 2011. The impact was isolated to a small area and <br /> included a crude oil spill that impacted soil and groundwater. Site #3 exhibited an impacted area <br /> measuring approximately 400 feet by 425 feet. The crude oil had been at the site for at least <br /> 30 years, and the plume was considered stable or decreasing in size. A Soil and Groundwater <br /> Management Plan was created to manage any subterranean work in the future. The plume <br /> extends under the Byron Road right-of-way. Based on the immobility of the weathered crude oil <br /> and the proximity to the Property, this case is unlikely to pose an environmental risk to the <br /> Property. <br /> Based on the distances to the identified database sites, regional topographic gradient, and the <br /> EDR findings, it is unlikely that the above-stated database sites pose an environmental risk to the <br /> Property. Properties that are on the "Orphan Summary" list appear to be located beyond the <br /> ASTM recommended radius search criteria. <br /> tNGEO January 28, 2022 <br /> -Expect Excellence- <br />