Laserfiche WebLink
SAN J Q A W N Environmen Ldl Health Department <br /> COUNTY Jasjit Kang, REHS, Director <br /> Greatness -rows l7 e re• (OPY <br /> Muniappa Naidu,REHS,Assistant Director PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Willy Ng, REHS <br /> Melissa Nissim, REHS <br /> Steven Shih, REHS <br /> July 26, 2021 <br /> Thoeed Asghar PA2200033 <br /> Eclipse Capital Property <br /> 415 Beatrice Ct., Ste. H <br /> Brentwood, CA 94513 <br /> RE: Soil Suitability/Nitrate Loading Study <br /> 26090 N. Thornton Rd, Thornton <br /> APN 001-150-48, SR0083931 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed the Soil Suitability/Nitrate <br /> Loading (SSNL) Study, dated June 23, 2021 and has the following comments for your consideration. <br /> The SSNL was prepared to determine the suitability of the above noted parcel for onsite wastewater treatment <br /> system (OWTS) usage and the potential long-term impact of nitrate to groundwater. <br /> Based on the information provided, the EHD can make the following findings: <br /> 1. The Soil Suitability/Nitrate Loading Study supports the suitability for standard OWTS usage for the <br /> proposed development project on the above-mentioned parcel, pursuant to San Joaquin County <br /> Ordinance Code Title 9, Section 9-1105.2(d). <br /> 2. Percolation test conducted on June 21, 2021 yield percolation rate of 6.25 minutes/inch. At this rate, <br /> an eight-foot soil separation shall be required between bottom of dispersal field and groundwater. <br /> Groundwater at the site fluctuate from 8.6 to 16.5 feet below ground surface San Joaquin County <br /> Onsite Wastewater Treatment Standard table 1.10.2. <br /> 3. Prior to issuance of building permit, open, pump and backfill the septic tank permit number (2223) <br /> under permit and inspection by the Environmental Health Department (San Joaquin County <br /> Development Title, Section 9-1110.3 & 9-1110.4). <br /> 4. According to permit (90-2884), there are three monitoring wells at the site. The septic system shall be <br /> at least 100 feet from any wells including monitoring wells. <br /> If you have any questions please contact Naseem Ahmed, Senior Registered Environmental Health <br /> Specialist, at nahmed@sjgov.org or (209) 616-3018. <br /> Otevenih, RENS <br /> Program Coordinator <br /> c: LiveOak <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/ehd <br />