Laserfiche WebLink
IMPORTANT:Ensure that each individual who will be involved in shipping/transportation of hazardous material is current with required training(awareness,function- <br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations. <br /> Geosyntec Procedures: HS-135-Hazardous Materials Procedures <br /> Site-Specific Notes&Clarifications: <br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> E.1. AIR MONITORING ® Applicable Not Applicable, Not Anticipated <br /> Site-Specific Notes,Clarifications: Site specific COCl are not believed to be an exposure risk to workers installing the SVPs;however,VOCs will be monitored in the <br /> breathing zone using a PID.Air monitoring of worker breathing zone will be performed by Geosyntec personnel while the boring is being advanced. A photoionization <br /> detector with 11.7 eV lamp,properly calibrated in accordance with manufacturer's instructions,will be used for monitoring of volatile organic compounds(VOCs)in the <br /> worker breathing zone during these activities. Worker breathing zone readings will be recorded on no less than a 15-minute frequency. Background readings will also be <br /> recorded and any sustained(longer than 5 seconds)detection above background levels will result in work stoppage so that engineering controls can be instituted;this will <br /> consist of electrically powered fans for the displacement of VOCs from the breathing zone.If sustained(longer than 5 seconds)detections above background level are still <br /> detected after engineering controls are in place then work shall stop and either additional engineering controls shall be put in use before resuming work activities or the <br /> boring will be terminated. <br /> The primary VOC compound of concern is Propylene dichloride(1,2-dichloropropane)which has a ACGIH®2018 8 hour limit of 10 ppm. <br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List. <br /> ®VOCs 1❑Oxygen(02)—oxygen meter €❑Particulates-total dust meter <br /> ®Photoionization detector(PID): 11.7 eV ❑Lower Explosive Level(LEL)-LEL meter ❑%Methane—methane meter <br /> ❑Flame ionization detector(FID) ❑Hydrogen sulfide(H2S)—H2S detector €❑Calibration kit for each parameter <br /> ❑Colorimetricindicatortubes—describe above I❑Carbon monoxide(CO)—COdetector El other: <br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels sustained general work-area levels for LEL). <br /> 19.5-23% Acceptable to continue work without 02-focused respiratory protection. <br /> 02 ........................_.........-.............................._.......................................................................................................................................................-...........-..........-.................................................................-...........-...................................................................................................... <br /> F-1 <br /> <19.5% ISTOP WORK,ventilate to raise Oz to>19.5%for re-entry. For persistent hazard,contact Corp.H&S Dept. <br /> Ox en ...................................................................._.............1........................... <br /> (Oxygen) <br /> Yg ) >23.0% STOP WORK,ventilate to lower 02 to<23%for re-entry.For persistent hazard,contact Corp.H&S Dept. <br /> IMPORTANT: Confirm sufficient oxygen is present(min.8-12%)to ensure accurate LEL readings. <br /> .......- ............................................. ......... ........ ........ ....... .. ........ ..... .......... ......................................................... <br /> ❑ LEL(Lower <10%LEL Acceptable to continue working in work area continue to monitor LEL. <br /> ..... .... ........ ........ ....... .....I... ....... ....... ........ ...... ......... <br /> Explosive Limit) o STOP WORK. Implement controls(reposition workers,ventilate,contain/eliminate source,etc.);resume <br /> >10%LEL work ONLY when LEL readings are<10%,sustained. <br /> <1 ppm Acceptable to continue work without H2S-focused respiratory protection. <br /> _............_..........................................................A......................................................................................................................................................-..........-..............................................................................-...........-..........-.......... <br /> .......................................................................................... <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> H2S 1-10 ppm exposures to<1ppm,or use APR*with VOC/acid-gas cartridges(yellow);do not exceed MUC*for respirator <br /> F-1 type;confirm acceptability of respirator usage with Corp.H&S Dept. <br /> (Hydrogen Sulfide) - <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> >10 ppm exposures to<10ppm(with respirator),or<1ppm(without respirator). For persistent levels>10 ppm,STOP <br /> WORK,contact Corp.H&S Dept. <br /> CO i <25 ppm Acceptable to continue work without CO-focused respiratory protection. <br /> ❑ Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> (Carbon Monoxide) >25 ppm exposures to<25ppm. For persistent levels>25ppm,STOP WORK,contact Corp.H&S Dept. <br /> <150 In this Air Quality Index(AQI)range,it's acceptable to continue work without respiratory protection. <br /> WILDFIRESMOKE —.........................._................... ......... ........ .......... ............... ........ ........ ....... ...... ..... .-... ......... ................................ <br /> ❑ 151-500 Voluntary use of N95 respirator is appropriate. <br /> (AQI for PM 2.5) `----- <br /> _...............................-..............................................................._*.......................p p........................................P..........._.........._._.p..._........_........_........_........_........_........._........._.........._................................................................ <br /> >500 STOP WORK,or use APR with approval of Corp.H&S Dept. <br /> ❑ <OTHER> i.................._............................_.........._.........._............................................._........._..................................._........._......... <br /> SITE-DERIVED ACTION LEVELS—Sustained breathing zone action levels;derived based on site contaminants;REVIEW WITH CORP.H&S DEPT.REQUIRED. <br /> <1 ppm (Acceptable to continue work without VOC-focused respiratory protection. <br /> ............................._............ <br /> >1 Implement controls(reposition workers,ventilation,containment,eliminate source,etc.) to lower VOC <br /> VOCs ppmexposures to less than specified action level,or use APR*with approval of Corp.H&S Dept. <br /> .................._..........._............_._........................................................................................................................................................................................................................................................................................................................................................................................................._ <br /> ® (Volatile Organic Use APR*with VOC cartridges(yellow or black);do not exceed MUC**for respirator type;confirm <br /> Compounds) X to X ppm <br /> procedures for respirator usage with Corp.H&S Dept. <br /> .........._..........._.........................._.........._............. ............................................................................................................................................................................................ <br /> >X ppm STOP WORK. Implement controls,for persistent levels greater than action contact Corp H&S Dept. <br /> <X mg/m3 Accepta ................................................................................................................................................................ .........._.........._..........._..........._................................................................................................................ <br /> ... <br /> > m m3 Implement controls(water spray,reposition workers,ventilation containment,etc)to lower dust levels to <br /> F-1 AIRBORNE DUST _ g/ less than specified action level,or use APR*with approval of Corp.H&S Dept. <br /> ......._. ....._..........................._... ...._................................. .... .... ......... <br /> (Total Particulates) X to X mg/m3 Use APR*with particulate cartridges appropriate for the hazard,do not exceed MUC**for respirator type; <br /> €confirm procedures for respirator usage with Corp.H&S Dept. <br /> _........... ...........-...........-............_..........._-.............................................................................................................................. <br /> Visible Dust Use wetting methods to control.For persistent levels greater than action level,contact Corp H&S Dept. <br /> Geosyntec ProjectlTask Name:TR0712/GSH OxyChem-Stockton SVP Installation <br /> THA Date:06/25/2022 Page 14 <br /> consultants <br />