IMPORTANT:Ensure that each individual who will be involved in shipping/transportation of hazardous material is current with required training(awareness,function-
<br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations.
<br /> Geosyntec Procedures: HS-135-Hazardous Materials Procedures
<br /> Site-Specific Notes&Clarifications:
<br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING
<br /> E.1. AIR MONITORING ® Applicable Not Applicable, Not Anticipated
<br /> Site-Specific Notes,Clarifications: Site specific COCl are not believed to be an exposure risk to workers installing the SVPs;however,VOCs will be monitored in the
<br /> breathing zone using a PID.Air monitoring of worker breathing zone will be performed by Geosyntec personnel while the boring is being advanced. A photoionization
<br /> detector with 11.7 eV lamp,properly calibrated in accordance with manufacturer's instructions,will be used for monitoring of volatile organic compounds(VOCs)in the
<br /> worker breathing zone during these activities. Worker breathing zone readings will be recorded on no less than a 15-minute frequency. Background readings will also be
<br /> recorded and any sustained(longer than 5 seconds)detection above background levels will result in work stoppage so that engineering controls can be instituted;this will
<br /> consist of electrically powered fans for the displacement of VOCs from the breathing zone.If sustained(longer than 5 seconds)detections above background level are still
<br /> detected after engineering controls are in place then work shall stop and either additional engineering controls shall be put in use before resuming work activities or the
<br /> boring will be terminated.
<br /> The primary VOC compound of concern is Propylene dichloride(1,2-dichloropropane)which has a ACGIH®2018 8 hour limit of 10 ppm.
<br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List.
<br /> ®VOCs 1❑Oxygen(02)—oxygen meter €❑Particulates-total dust meter
<br /> ®Photoionization detector(PID): 11.7 eV ❑Lower Explosive Level(LEL)-LEL meter ❑%Methane—methane meter
<br /> ❑Flame ionization detector(FID) ❑Hydrogen sulfide(H2S)—H2S detector €❑Calibration kit for each parameter
<br /> ❑Colorimetricindicatortubes—describe above I❑Carbon monoxide(CO)—COdetector El other:
<br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels sustained general work-area levels for LEL).
<br /> 19.5-23% Acceptable to continue work without 02-focused respiratory protection.
<br /> 02 ........................_.........-.............................._.......................................................................................................................................................-...........-..........-.................................................................-...........-......................................................................................................
<br /> F-1
<br /> <19.5% ISTOP WORK,ventilate to raise Oz to>19.5%for re-entry. For persistent hazard,contact Corp.H&S Dept.
<br /> Ox en ...................................................................._.............1...........................
<br /> (Oxygen)
<br /> Yg ) >23.0% STOP WORK,ventilate to lower 02 to<23%for re-entry.For persistent hazard,contact Corp.H&S Dept.
<br /> IMPORTANT: Confirm sufficient oxygen is present(min.8-12%)to ensure accurate LEL readings.
<br /> .......- ............................................. ......... ........ ........ ....... .. ........ ..... .......... .........................................................
<br /> ❑ LEL(Lower <10%LEL Acceptable to continue working in work area continue to monitor LEL.
<br /> ..... .... ........ ........ ....... .....I... ....... ....... ........ ...... .........
<br /> Explosive Limit) o STOP WORK. Implement controls(reposition workers,ventilate,contain/eliminate source,etc.);resume
<br /> >10%LEL work ONLY when LEL readings are<10%,sustained.
<br /> <1 ppm Acceptable to continue work without H2S-focused respiratory protection.
<br /> _............_..........................................................A......................................................................................................................................................-..........-..............................................................................-...........-..........-..........
<br /> ..........................................................................................
<br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit
<br /> H2S 1-10 ppm exposures to<1ppm,or use APR*with VOC/acid-gas cartridges(yellow);do not exceed MUC*for respirator
<br /> F-1 type;confirm acceptability of respirator usage with Corp.H&S Dept.
<br /> (Hydrogen Sulfide) -
<br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit
<br /> >10 ppm exposures to<10ppm(with respirator),or<1ppm(without respirator). For persistent levels>10 ppm,STOP
<br /> WORK,contact Corp.H&S Dept.
<br /> CO i <25 ppm Acceptable to continue work without CO-focused respiratory protection.
<br /> ❑ Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit
<br /> (Carbon Monoxide) >25 ppm exposures to<25ppm. For persistent levels>25ppm,STOP WORK,contact Corp.H&S Dept.
<br /> <150 In this Air Quality Index(AQI)range,it's acceptable to continue work without respiratory protection.
<br /> WILDFIRESMOKE —.........................._................... ......... ........ .......... ............... ........ ........ ....... ...... ..... .-... ......... ................................
<br /> ❑ 151-500 Voluntary use of N95 respirator is appropriate.
<br /> (AQI for PM 2.5) `-----
<br /> _...............................-..............................................................._*.......................p p........................................P..........._.........._._.p..._........_........_........_........_........_........._........._.........._................................................................
<br /> >500 STOP WORK,or use APR with approval of Corp.H&S Dept.
<br /> ❑ <OTHER> i.................._............................_.........._.........._............................................._........._..................................._........._.........
<br /> SITE-DERIVED ACTION LEVELS—Sustained breathing zone action levels;derived based on site contaminants;REVIEW WITH CORP.H&S DEPT.REQUIRED.
<br /> <1 ppm (Acceptable to continue work without VOC-focused respiratory protection.
<br /> ............................._............
<br /> >1 Implement controls(reposition workers,ventilation,containment,eliminate source,etc.) to lower VOC
<br /> VOCs ppmexposures to less than specified action level,or use APR*with approval of Corp.H&S Dept.
<br /> .................._..........._............_._........................................................................................................................................................................................................................................................................................................................................................................................................._
<br /> ® (Volatile Organic Use APR*with VOC cartridges(yellow or black);do not exceed MUC**for respirator type;confirm
<br /> Compounds) X to X ppm
<br /> procedures for respirator usage with Corp.H&S Dept.
<br /> .........._..........._.........................._.........._............. ............................................................................................................................................................................................
<br /> >X ppm STOP WORK. Implement controls,for persistent levels greater than action contact Corp H&S Dept.
<br /> <X mg/m3 Accepta ................................................................................................................................................................ .........._.........._..........._..........._................................................................................................................
<br /> ...
<br /> > m m3 Implement controls(water spray,reposition workers,ventilation containment,etc)to lower dust levels to
<br /> F-1 AIRBORNE DUST _ g/ less than specified action level,or use APR*with approval of Corp.H&S Dept.
<br /> ......._. ....._..........................._... ...._................................. .... .... .........
<br /> (Total Particulates) X to X mg/m3 Use APR*with particulate cartridges appropriate for the hazard,do not exceed MUC**for respirator type;
<br /> €confirm procedures for respirator usage with Corp.H&S Dept.
<br /> _........... ...........-...........-............_..........._-..............................................................................................................................
<br /> Visible Dust Use wetting methods to control.For persistent levels greater than action level,contact Corp H&S Dept.
<br /> Geosyntec ProjectlTask Name:TR0712/GSH OxyChem-Stockton SVP Installation
<br /> THA Date:06/25/2022 Page 14