Laserfiche WebLink
ASEATING PLAN 1/4" = 1'-0"DWALL LEGEND TWHCFLOOR NOTES <br />BKEY NOTES <br /> ALL GENDER 1 <br /> ALL GENDER 2 <br />DINING <br />41 SEATS <br />STORAGE <br />KITCHEN <br />B <br />A4.1 <br />A <br />A4.0 <br />A <br />A4.1 <br />DIMENSIONS: <br />A. <br />B. <br />WINDOWS / DOORS: <br />A. <br />B. <br />FINISH SUBSTRATES: <br />A. <br />B. <br />C. <br />DECOR: <br />A. <br />B. <br />C. <br />D. <br />GENERAL: <br />A. <br />B. <br />C. <br />D. <br />ALL DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC. <br />DIMENSIONS. <br />DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE FROM FACE OF WALL <br />/ WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING. <br />SEE SHT. A1.1 FOR WINDOW TYPES AND DOOR SCHEDULE. <br />ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING. <br />PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN LIEU OF GYP. BD. <br />AT ALL WALLS EXCEPT SHEARWALL SURFACES, U.O.N. <br />ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE <br />SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. <br />ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE, U.O.N. <br />SEE A2.0 FOR SEATING PLAN AND DETAILS. <br />SEE A7.0 FOR FLOOR FINISHES. <br />SEE A8.0 - A8.3 FOR WALL FINISHES. <br />SEE A7.1 FOR CEILING FINISHES. <br />PROVIDE THREE FIRE EXTINGUISHERS - (2) 10 lb. BC and (1) 10 lb. K - TO COMPLY WITH LOCAL FIRE <br />CODE. LOCATE PER CFC 906.1 & DIRECTION OF FIRE MARSHALL OR LOCAL AUTHORIZING AGENT. <br />DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ON NON-BEARING <br />INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE. <br />ALL ATTACHMENTS MADE THROUGH STUCCO SHALL BE BUSHED TO PREVENT DAMAGE TO THE <br />FINISH. <br />ALL PENETRATIONS THROUGH STUCCO SHALL BE SEALED USING MFR'S. APPROVED METHOD. <br />TYPICAL NEW EXTERIOR WALL: <br />7/8" EXTERIOR STUCCO FINISH OVER (2) LAYERS GRADE "D" BUILDING <br />PAPER OVER 1/2" EXTERIOR GRADE SHEATHING OVER 2x6 STUDS @ <br />16" O.C. <br />TYPICAL NEW INTERIOR WALL: <br />2x4 WD STUDS (2X6 WHERE NOTED) AT 16" O.C. W/ 1/2" GYP. BD. <br />SUBSTRATE U.O.N. USE MOISTURE RESISTANT GYP. BD. BEHIND ALL <br />CERAMIC WALL TILE. U.O.N. <br />EXISTING INTERIOR WALL: <br />PATCH AND REPAIR, REFINISH/PAINT AS NECESSARY. SEE FINISH <br />SCHEDULE. <br />1 RI <br />2 RI <br />3 RI <br />4 RI <br />5 RI <br />9 RI <br />8 RI <br />7 RI <br />6 RI <br />10 RI <br />11 RI <br />12 RI <br />13 RI <br />14 RI <br />PATCH STUCCO AS NEEDED. <br />PROTECT KITCHEN EQUIPMENT DURING CONSTRUCTION . <br />EXISTING ELECTRICAL MAIN SWITCH BOARD. REFER TO ELECT. DWGS. <br />(E) WINDOWS AND STOREFRONT TO REMAIN, CLEAN AND REPAIR ANY DAMAGE. TYP. <br />CONSTRUCT PLYWOOD DUST BARRIER WITH LOCKING SWING GATE TO PROTECT KITCHEN <br />DURING CONSTRUCTION <br />GC TO VERIFY THERE ARE TWO EXISTING PORTABLE 2A-10BC FIRE EXTINGUISHERS WITH <br />MAXIMUM TRAVEL DISTANCE OF 75' BETWEEN THEM. IF NOT GC TO PROVIDE REQUIRED FIRE <br />EXTINGUISHERS AND MOUNT THEM WHERE DIRECTED BY THE FIRE INSPECTOR. <br />(E) WATER HEATER. <br />(E) CO2 TANK. RELOCATED. <br />RELOCATE (E) HANDWASH SINK. REUSE (E) PIPING. <br />(N) PICKUP WINDOW.. <br />NOT USED. <br />NEW INTERIOR WALL. REPLACE ANY DAMAGED TILES ON FLOOR. <br />OCCUPANCY SIGN: MAX OCCUPANCY 85. <br />ADA ENTRANCE CLEARANCES. <br />NOT USED. <br />E) ROOF LADDER TO REMAIN. <br />NOT USED. <br />(E) MOP SINK. REPAIR.RE-FINISH TILE SURROUND AND FLOOR. <br />(N) AIR CURTAIN ABOVE PICKUP WINDOW. <br />(N) WAINSCOT COVERING AND (E) CHAIR RAIL. <br />LOW DINING WALL. SEE A8.0. <br />15 RI <br />17 RI <br />REMODEL IMAGE (RI) <br />18 RI <br />19 RI <br />20 RI <br />21 RI <br />16 RI <br />KEYNOTE SYMBOL ON PLAN <br />EXIT <br />JAN. <br />PICKUP <br />HALLWAY <br />WAREWASHING <br />OFFICE <br />ENTRY <br />ENTRY <br />5 RI <br /> 19 RI <br />4 RI <br />4 RI <br />6 RI <br />6 RI <br />6 RI <br />7 RI <br />6 RI <br />2 RI <br />1 RI <br />12 RI <br />12 RI <br />9 RI <br />13 RI <br />16 RI <br />18 RI <br />20 RI <br />21 RI <br />21 RI <br />21 RI <br /> 21 RI <br />14 RI <br />14 RI <br />7'-5 1/2"9'-6 1/2"2'-7"4'-4"2'-7 1/2"14'-8 1/2"14'-0 1/2" <br />FOS <br />FOF <br />FOS <br />FOF <br />2 <br />A8.2 <br />COOKING <br />10 RI <br />A1-0 <br />FLOOR PLAN <br />REVISIONS <br />ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF PROJECT ARCHITECT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR, ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED.NORTH <br />W:\Data\Golden Gate Bell\21036_GGB_Tracy_STracyBlvd_30810\03_cd\_current\200_21036_A1-0_Floor Plan.dwg By: PMOSS Saved on:3/17/2022 5:02:12 PMRECORD DATES <br />DD SUBMITTAL <br />BLDG. SUBMITTAL <br />BID SET <br />CONTRACT SET <br />- <br />07/02/2021 <br />- <br />VMI JOB NUMBER <br />21036 <br />CLIENT <br />GOLDEN GATE BELL <br />3120 S. DURANGO DRIVE <br />LAS VEGAS, NV 89117 <br />Contact: Chris Czyz, (602) 714-3099 <br />SITE #30810 <br />PROJECT <br />TACO BELL REMODEL <br />915 S. TRACY BLVD. <br />TRACY, CA. 95376 <br />APN #TBD <br />ENDEAVOR <br />SUCCESSOR <br />637 5th Avenue San Rafael, CA 94901 <br />415-451-2500 415-451-2595 fax <br />www.vmarchitecture.com <br />Design ~ Planning ~ Interiors <br />N IA <br />T <br />AFOC <br />TE OFLI R <br />SL T <br />CEDD <br />No. C17928 <br />REN. 10/31/23UGHH AM <br />YHPURR <br />RW <br />DE <br />A <br />A <br />IECN S <br />E <br />CH <br />TI <br />NOTE - <br />NO CORE DRILL CHAIRS OR TABLES