My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
915
>
1600 - Food Program
>
PR0506843
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 12:46:05 PM
Creation date
10/18/2022 3:35:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0506843
PE
1624
FACILITY_ID
FA0007664
FACILITY_NAME
TACO BELL #30810
STREET_NUMBER
915
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202025
CURRENT_STATUS
01
SITE_LOCATION
915 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ASEATING PLAN 1/4" = 1'-0" <br />U-131 2 NEW MOUNTING PLATE 1 PER KIOSK TABLET <br />U-135 KIOSK TABLET PROVIDE DEDICATED CIRCUIT AND (2) TWO CAT 6 CABLES PER TABLET <br />U-136 VERIFONE (CREDIT CARD MACHINE)1 PER KIOSK TABLET <br />ENEW EQUIPMENT <br />2 NEW <br />2 NEW <br />U-130 1 NEW KIOSK TABLE 1 PER STORE <br />U-137 STORM AUDIO - NAV KEYPAD 1 PER KIOSK TABLET2 NEW <br />EQ #Count Description <br />RELATED KIOSK EQUIPMENT <br />S-287 FRUITESTA CART1 NEW SPG / ISS <br />REFRREFRREFRREFRREFRTWHREFR <br />REFR <br />REFR <br />FRYERS <br />FRYERS <br />MOBILE <br />PICKUP <br />CO2 <br />TANK <br />NEW PICKUP <br />HGRAPHIC VENDOR <br />NEW DOOR FRAMES <br />PAINT P-3 <br />NEW DOOR PANELS FINISH: <br />WILSONART "MOCHA ASH" <br />Y0665-12 HIGH PRESSURE <br />LAMINATE, (IDX) (L-2) <br />3'-0" <br />V.I.F.6'-8"V.I.F.SEE SHEET A2.1 DOOR <br />SCEDULE FOR MORE DETAILS <br />L-2 <br />IMPACT SPECIALTIES <br />JEN DAVIS <br />PHONE: (619) 481-9588 <br />EMAIL: JDAVIS@IMPACTSPECIALTIES.COM <br />1."HOLD" DIMENSIONS FROM FACE OF FINISH. <br />2.G.C. TO CONFIRM "HOLD" DIMENSIONS WITH EQUIPMENT <br />MFR/VENDOR. <br />3.TILE CHIPPING AROUND CORE DRILL HOLES FOR SEATING <br />WILL NOT BE ACCEPTED. <br />4.ALL DIMENSIONS FOR SEATING / CORE DRILL PLAN SHALL <br />BE FROM FACE OF GYP BD. <br />5.VERIFY ALL DIMENSIONS WITH SEATING VENDOR PRIOR TO <br />INSTALLATION. <br />6.REFER TO T1-0 SHEET FOR SCOPE OF WORK <br />RESPONSIBILITIES. <br />7.SEE INTERIOR ELEVATIONS A8-0 FOR LOCATION OF OWNER <br />SUPPLIED ARTWORK. <br />8.(H) - SYMBOL DENOTES A HIGH TABLE OR DINING COUNTER. <br />SYMBOL DENOTES A HANDICAP ACCESSIBLE TABLE. <br />CSEATING PLAN NOTES <br />DGRAPHIC VENDOR <br />BKEY NOTES <br />KEYNOTE SYMBOL ON PLAN <br />1.(N) SERVICE COUNTER SUPPLIED BY VENDOR INSTALLED <br />BY GC. <br />2.ADA CLEARANCE REQUIREMENTS. MAINTAIN 30" x 48" <br />CLEAR FLOOR SPACE FOR HANDICAP ACCESS. <br />3.36" MIN. LONG x 34" HIGH COUNTERTOP REQUIRED PER <br />ADA. <br />4.REINSTALL (E) DRINK STATION AND (E) ICE MACHINE ON <br />(E) SS TABLE. RECONNECT ELECTRICAL AND PLUMBING <br />AND OVERHEAD SYRUP LINES AS REQUIRED FOR <br />RECONNECTION. RELOCATE FLOOR SINK AS REQUIRED <br />PER HEALTH DEPT. <br />5.NEW 3 STREAM TRASH ENCLOSURE UNIT. <br />6.NEW HIGH CHAIR BY OWNER. (F-500) <br />7.(N) DIGITAL MENU BOARD. SEE A7.1 FOR ELECTRICAL <br />REQUIREMENTS. L-043 <br />8.GC TO VERIFY THERE ARE TWO EXISTING PORTABLE <br />2A-10BC FIRE EXTINGUISHERS AND ONE K EXTINGUISHER <br />WITH MAXIMUM TRAVEL DISTANCE OF 75' BETWEEN <br />THEM. IF NOT GC TO PROVIDE REQUIRED FIRE <br />EXTINGUISHERS AND MOUNT THEM WHERE DIRECTED BY <br />THE FIRE INSPECTOR. <br />9.RE-INSTALL (E) TABLE/CABINET AFTER FLOOR AND WALL <br />TILE WORK IS FINISHED SEE A8.0. <br />10.MAINTAIN 44" MIN. CLEAR PATH OF TRAVEL. <br />11.NEW TABLES & CHAIRS, REFER TO DECOR VENDOR <br />DRAWINGS. <br />12.INSTALL UNDER COUNTER CUP DISPENSER WITH <br />ANGLED BRACKETS. <br />13.NOT USED. <br />14.REWORK EXISTING POWER FOR POS ITEMS ON NEW <br />ORDER COUNTER. <br />15.NEW FLOOR AND WALL TILES IN RESTROOMS, SEE A8.1, <br />ENLARGED RESTROOM PLAN, FOR MORE DETAILS. <br />16.HOLES FOR POS CASH REGISTER POWER AND DATA LINE <br />SHOULD BE FIELD CUT BY GC PRIOR TO POS SETUP <br />(TYP). <br />17.EXISTING KITCHEN EQUIPMENT REINSTALLED IN SAME <br />LOCATIONS AFTER NEW FLOOR INSTALLED. <br />18.(N) WALL ART. SEE ELEVATIONS SHEET A8.0 FOR SIZE <br />AND LOCATION. <br />19.REPLACE (E) TILE FLOORING AT KITCHEN. SEE SHEET <br />A7.0, FINISH PLAN, FOR MORE DETAILS. <br />20.RE-INSTALL (E) ELECTRICAL HAND DRYER AFTER NEW <br />WALL TILE INSTALLED. <br />21.HUB TABLE POWER PROVIDED FROM CEILING. RUN FLEX <br />CABLE WIRING TO AND THROUGH CHASE DOWN TUBE <br />TO JUNCTION BOX ON UNDERSIDE OF TABLE. <br />22.(E) FRUITISTA FROZEN DRINK DISPENSER ON (N) CART <br />AND SHROUD. relocate to opposite wall <br />23.RE-INSTALL (E) FREE-STANDING WALK- IN COOLER / <br />FREEZER AFTER (N) FLOORING INSTALLED. <br />24.FOR EXTENT OF WALL TILE REFER TO INTERIOR <br />ELEVATIONS. <br />25.NEW CONDIMENT COUNTER BY DECOR VENDOR. <br />26.NEW ORDER KIOSKS ON LOW WALL AFTER WORK IS <br />COMPLETE. PROVIDE DATA AND POWER TO LOW WALL/ <br />KIOSK BY CHASE IN CONC SLAB (BEFORE NEW FLOOR <br />TILE INSTALLED IN DINING). <br />27.NEW DOORS SUPPLIED BY DECOR VENDOR WITH NEW <br />LAMINATE BOTH SIDES, INSTALLED BY GC. DOOR FRAMES <br />TO BE REPAINTED BY GC, SEE A8.0 . <br />28.NEW OCCUPANCY SIGN. OCCUPANCY "52 MAX". <br />29.NEW CORNER GUARD AT MURAL. <br />30. NEW RESTROOM ACCESSIBLE SIGNAGE. PER ADA <br />1/ADA-3. <br />31. SS END WALL COVER/GUARD. <br />32. RELOCATED HAND SINK. <br />33. NEW WALL. <br />34. RELOCATED DRINK SYRUP LINES. <br />35. RELOCATED CO2 TANK. <br />36. NEW MOBILE PICK UP CART. <br />37. NEW AIR CURTAIN. SEE <br /># <br />T-620e <br />25 <br /> ALL GENDER 1 <br />1 <br />2 <br />30 <br />27 <br />27 <br />17 <br />1 <br />5 <br />8 <br />8 <br />8 <br />5 <br />T-708e <br />18 <br />G-156 <br />18 <br />18 <br />G-156 <br />18 <br />18 <br />G-156 <br />18 <br /> ALL GENDER 2 <br />2 <br />2 <br />2 <br />2 <br />U-136 <br />U-135 <br />U-137 <br />U-136 <br />U-135 <br />U-137 <br />U-136 <br />U-135 <br />U-137 <br />U-136 <br />U-135 <br />U-137 <br />16 <br />36 <br />L403L403L403L403 <br />31 <br />T-613e <br />3 <br />14 <br />16 <br />22 <br />23 <br />21 <br />26 <br />28 <br />29 29 47 <br />15 <br />15 <br />9 <br />6 <br />19 <br />20 <br />20 <br />T-408 <br />T-901e (2) <br />T-409e <br />T-901e (2) <br />T-411e <br />T-901e <br />T-302be <br />T-302e <br />T-302be <br />T-302e <br />T-302be <br />T-302e <br />T-405e <br />T-901e <br />(2) <br />11 TYP. <br />T-405e(2)T-405e <br />T-901e <br />(4) <br />11 <br />TYP.T-901e <br />(4) <br />T-405e <br />T-901e <br />(2) <br />T-405e <br />T-901e <br />(4) <br />T-201e <br />(6)11 TYP. <br />T-401e <br />T-402e <br />3 <br />T-901e <br />(4)3'-8"103'-8" <br />10 <br />3'-8" <br />10 <br />11 TYP. <br />12 <br />14 <br />24 <br />32 <br />B-120 <br />33 <br />33 <br />35 <br />B-60X <br />37 <br />U-061 <br />U-100 <br />(2)T-620e <br />U-121 <br />U-070 <br />S-600 <br />S-580 <br />S-600S-550 <br />S-513 <br />S-573 <br />U-238 <br />U-239 <br />S-444 <br />S-443 <br />S-482 <br />S-489 <br />U-061 <br />U-100 <br />U-070 <br />U-121 <br />S-600 <br />S-513 <br />S-570 <br />S-443 <br />S-444 <br />S-482 <br />S-489 <br />U-238 <br />U-239 <br />FURNITURE/DECOR SCHEDULE <br />EQ #Count Description <br />D-700 4 22" x 22" x 28.5" H FREE STANDING TABLE BASE <br />D-703 7 22" x 5.5" x 28.5" H FREE STANDING TABLE BASE <br />T-302be 3 BENCH BACK REST - 48" <br />T-303be 1 BENCH BACK REST - 60" <br />T-402e 1 <br />EQUIPMENT SCHEDULE <br />EQ#Count Description <br />T-302e 3 BENCH SEAT - 48" <br />T-303e 1 BENCH SEAT - 60" <br />T-401e 1 HUB TABLE - 72" - HIGH TOP <br />T-405e 2 <br />T-201e 6 BARREL BARSTOOL - 29 PURPLE WOOD SEAT <br />T-408e <br />T-411e <br />T-505e <br />T-620e <br />T-506e <br />T-706e <br />T-708e <br />T-901e <br />HUB TABLE - 48" - LOW TOP <br />LAMINATE TABLE - 24" x 20" x 30" - 2 TOP <br />LAMINATE TABLE ADA - 24" x 48" x 30" - 4 TOP <br />SS TABLE - 24 DIA. x 30" - 2 TOP <br />COUNTER TOP - 48" x 20" x 30" <br />COUNTER TOP - 60" x 20" x 30" <br />CONDIMENT COUNTER - RECTANGLE <br />SINGLE STREAM TRASH ENCLOSURE <br />3 - STREAM TRASH ENCLOSURE <br />CHAIR - BLACK METAL FRAME, LAMINATE SEAT <br />4 <br />2 <br />1 <br />1 <br />1 <br />1 <br />26 <br />1 <br />T-613e POS COUNTER1 <br />ARTWORK SCHEDULE <br />EQ#Count Description <br />G-326 1 MURAL <br />G-156 1 28"X40" <br />L-043 4 43SL5D 22.7" x 38.2" DIGITAL QUEUE BOARD DISPLAY <br />B-60X 1 AIR CURTAIN -"MARS" - LPV30-1U - # E76000339 <br />B-120 1 PICKUP WINDOW - "QUIKSERV" - SC-4030 CALI (LEFT) <br />Z-XXX 1 FREE-STANDING MOBILE PICK UP CART <br />Z-XXX <br />2 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />RECIEPT PRINTER EPSON <br />RECIEPT PRINTER EPSON <br />CREDIT CARD READER <br />POS/ORDER ENTRY TERMINAL <br />CASH DRAWER BRACKETS #SU186075Y <br />KITCHEN MONITOR IBM, NCR & PAR <br />MONITOR CEILING MOUNTED BRACKET IBM, NCR & PAR <br />LID DISPENSER CAL-MIL ADA TB103 <br />NAPKIN DISPENSER TOR XPRESSNAP #5555100 <br />CUP DISPENSER A.J. ATUNES #DACS60 <br />SCALE EDLUND <br />ICE MAKER(DRINK MACHINE)MANITOWOC, KMS-1401MLJ <br />CARBONATOR CORNELIUS/REMCOR <br />BUNDLED SYRUP LINES CORNELIUS/REMCOR <br />S-254 <br />S-28X <br />S-349 <br />1 <br />1 <br />2 <br />CONTAMINATE RACK <br />STAGING COUNTER 30" x 60" <br />PICKUP STATION 30" x 42" <br />S-28X <br />S-254 <br />A2-0 <br />SEATING PLAN <br />REVISIONS <br />ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF PROJECT ARCHITECT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR, ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED.NORTH <br />W:\Data\Golden Gate Bell\21036_GGB_Tracy_STracyBlvd_30810\03_cd\_current\200_21036_A2-0_Seating and Equipment Plan.dwg By: PMOSS Saved on:3/18/2022 2:37:35 PMRECORD DATES <br />DD SUBMITTAL <br />BLDG. SUBMITTAL <br />BID SET <br />CONTRACT SET <br />- <br />07/02/2021 <br />- <br />VMI JOB NUMBER <br />21036 <br />CLIENT <br />GOLDEN GATE BELL <br />3120 S. DURANGO DRIVE <br />LAS VEGAS, NV 89117 <br />Contact: Chris Czyz, (602) 714-3099 <br />SITE #30810 <br />PROJECT <br />TACO BELL REMODEL <br />915 S. TRACY BLVD. <br />TRACY, CA. 95376 <br />APN #TBD <br />ENDEAVOR <br />SUCCESSOR <br />637 5th Avenue San Rafael, CA 94901 <br />415-451-2500 415-451-2595 fax <br />www.vmarchitecture.com <br />Design ~ Planning ~ Interiors <br />N IA <br />T <br />AFOC <br />TE OFLI R <br />SL T <br />CEDD <br />No. C17928 <br />REN. 10/31/23UGHH AM <br />YHPURR <br />RW <br />DE <br />A <br />A <br />IECN S <br />E <br />CH <br />TI <br />NOTE - <br />NO CORE DRILL CHAIRS OR TABLES
The URL can be used to link to this page
Your browser does not support the video tag.