Laserfiche WebLink
CONSTRUCTION NOTES1.CONSTRUCT SIDEWALKS WITH THE SLOPE 0.5% LESS THAN THE MAXIMUM ALLOWABLE ADA STANDARD.2.ALL CLEAR DISTANCES ARE "CLEAR" TO THE FACE OF FINISH AND/ OR VENEER.HAZARDS AND PROTRUDING OBJECTS1.MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A SINGLE, STATIONARYWHEELCHAIR AND OCCUPANT IS 30 INCHES BY 48 INCHES. MINIMUM CLEAR FLOOR OR GROUND SPACEFOR WHEELCHAIRS MAY BE POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT. FLOOROR GROUND SPACE FOR WHEELCHAIRS MAY BE PART OF THE KNEE SPACE REQUIRED UNDER SOMEOBJECTS.2.PROVIDE AN ADDITIONAL 12 INCHES WIDTH ON ONE SIDE FOR ALCOVES GREATER THAN 15 INCHES DEEPAND DESIGNED FOR SIDE APPROACH.3.PROVIDE AN ADDITIONAL 6 INCHES WIDTH ON ONE SIDE FOR ALCOVES GREATER THAN 24 INCHES DEEPAND DESIGNED FOR FRONT APPROACH.4.OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 INCHESABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4 INCHES INTO WALKS, HALLS,CORRIDORS, PASSAGEWAYS, OR AISLES.5.OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27 INCHES ABOVE THE FINISHED FLOORMAY PROTRUDE ANY AMOUNT.6.FREESTANDING OBJECTS MOUNTED ON POSTS / PYLONS MAY OVERHANG 12 INCHES MAXIMUM FROM 27INCHES TO 80 INCHES ABOVE THE GROUND OR FINISHED FLOOR.7.PROTRUDING OBJECTS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE ROUTE ORMANEUVERING SPACE.8.ANY OBSTRUCTION OVERHANGING A PEDESTRIAN WAY SHALL BE A MINIMUM OF 80 INCHES ABOVE THEWALKING SURFACE AS MEASURED TO THE BOTTOM OF THE OBSTRUCTION.PARKING1.SURFACE SLOPES OF ACCESSIBLE PARKING SPACES FOR THE PHYSICALLY DISABLED SHALL NOT EXCEED3/16 INCH PER FOOT (2% GRADIENT) IN ANY DIRECTION.2.DISABLED PARKING SPACES SHALL BE LOCATED SO AS NOT TO REQUIRE USERS TO WHEEL OR WALKBEHIND ANY OTHER NON-DISABLED OR DISABLED PARKING SPACE.3.IN EACH PARKING AREA, A BUMPER OR CURB SHALL BE PROVIDED AND LOCATED TO PREVENTENCROACHMENT OF CARS OVER THE REQUIRED WIDTH OF WALKWAYS.4.PARKING SPACES RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES SHALL BE IDENTIFIED BY AREFLECTIVE SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL ORSPACE, CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUEBACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 INCHES IN AREA AND, WHEN IN THE PATH OFTRAVEL, SHALL BE POSTED AT A MINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OF THE SIGN TO TOPOF SIDEWALK. SIGNS MAY ALSO BE CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKINGSPACE AT A MINIMUM HEIGHT OF 36 INCHES FROM THE PARKING SPACE FINISHED GRADE, GROUND, ORSIDEWALK (WHICHEVER IS HIGHEST).WALKS AND SIDEWALKS1.WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE NOT EXCEEDING 2% CROSSSLOPE AND SHALL NOT BE INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL WHICH EXCEED 1/4INCH, AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH. SURFACES SHALL BE SLIP RESISTANT.2.ANY OBSTRUCTION OVER WALKWAYS SHALL HAVE A CLEAR VERTICAL CLEARANCE OF 80 INCHES. ANOBJECT SHALL NOT PROTRUDE INTO WALKWAY MORE THAN 4 INCHES.3.WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVER POSSIBLE. GRIDOPENINGS WITHIN GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS SHALL BE LIMITED TO1/2 INCH IN THE DIRECTION OF THE TRAFFIC FLOW.4.WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL(5%), IT SHALL COMPLY WITH THE PROVISIONS OF PEDESTRIAN RAMPS.5.A LEVEL AREA, 2% MAX SLOPE, SHALL BE PROVIDED AT ALL DOORS. REFER TO ENTRANCE NOTES BELOWAND ACCESSIBLE DETAILS FOR CLEAR SPACE REQUIREMENTS.6.WARNING CURBS, MINIMUM 6 INCHES IN HEIGHT, SHALL BE PROVIDED FOR ANY ABRUPT LEVEL CHANGEADJACENT TO WALKWAYS EXCEPT AT ADJACENT STREET OR DRIVEWAY / PARKING STALL.AACCESSIBILITY NOTES7.HANDRAILS AT THE TOP OF STAIRWAYS SHALL EXTEND A MINIMUM OF 12 INCHES OF LEVEL DISTANCEBEYOND THE TOP NOSING. HANDRAILS AT THE BOTTOM OF STAIRWAYS SHALL EXTEND A MINIMUM OFTREAD WIDTH PLUS 12 INCHES BEYOND THE BOTTOM NOSING BEFORE THEY ARE RETURNED. AT THEBOTTOM, THE HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE WIDTH OF ONE TREAD FROMTHE BOTTOM RISER. THE REMAINDER OF THE EXTENSION SHALL BE HORIZONTAL (LEVEL).8.WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF THE STAIR RUN WOULD CREATE AHAZARD, THE EXTENSION SHALL BE MADE AT RIGHT ANGLES, ON THE FACE OF A RETURNING WALL.WHERE THE STAIRS ARE CONTINUOUS THE HANDRAIL SHALL BE CONTINUOUS AND NEED NOT EXTEND OUTINTO THE LANDING.9.ALL HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS.10.ALL HANDRAILS PROJECTED FROM A WALL SHALL HAVE AN ABSOLUTE CLEARANCE OF 1-1/2 INCHESBETWEEN THE WALL AND THE HANDRAIL.11.THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4 INCH NOR MORE THAN 1-1/2 INCHOUTSIDE DIAMETER IN CROSS-SECTION (1-1/2" STD. PIPE IS ACCEPTABLE) DIMENSION OR THE SHAPESHALL PROVIDE AN EQUIVALENT SMOOTH GRIPPING SURFACE WITH NO SHARP CORNERS.RAMPS1.ALL RAMPS USED AS EXITS AND ANY PATH OF TRAVEL HAVING A SLOPE GREATER THAN 1:20 (5%) SHALLCOMPLY WITH THE REQUIREMENTS OF THIS SECTION. RAMPS SHALL HAVE THE LEAST POSSIBLE SLOPE.2.PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCES TO A BUILDING SHALL HAVE A MINIMUM WIDTH OF 48INCHES.3.ALL RAMPS IN AREAS ACCESSIBLE TO PERSONS WITH DISABILITIES ON A PATH OF TRAVEL OR SERVINGEXITS SHALL HAVE A 1:12.5 (8.0%) MAXIMUM SLOPE WITH CROSS SLOPES NO GREATER THAN 1:65 (1.5%).4.THE LEVEL LANDING WIDTH OF ANY RAMP SHALL EXTEND PAST THE STRIKE EDGE OF ANY DOOR OR GATEAS SHOWN ON DETAILS.5.DOORS STANDING IN ANY POSITION SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP TO LESSTHAN 42 INCHES OR THE REQUIRED WIDTH BY MORE THAN 3 INCHES WHEN FULLY OPEN (CA. ONLY).6.ALL CURB RAMPS SHALL BE PROVIDED WITH TRUNCATED DOMES TO COMPLY WITH THE MINIMUMREQUIREMENTS OF A.D.A.A.G. AND THE LATEST CA-24 ACCESS REQUIREMENTS.7.HANDRAILS ARE REQUIRED ON RAMPS WHEN THE SLOPE EXCEEDS 1:20 (5%). HANDRAILS AT RAMPS SHALLRUN ALONG BOTH SIDES OF A RAMP, BE CONTINUOUS THE FULL LENGTH, HANDRAILS SHALL EXTEND AMINIMUM OF 12 INCHES OF LEVEL DISTANCE BEYOND THE TOP AND BOTTOM OF THE RAMP. HANDRAILEXTENSIONS SHALL RETURN TO THE LAST SUPPORT OF THE HANDRAIL.8.THE HANDRAIL GRIP SURFACE AT RAMPS SHALL BE MOUNTED BETWEEN 34 INCHES AND 38 INCHES ABOVETHE RAMP SURFACE.9.RAMPS WITH A RISE GREATER THAN 6 INCHES SHALL HAVE HANDRAILS ON BOTH SIDES.10.GUARDS SHALL BE LOCATED ALONG OPEN SIDED WALKING SURFACES, STAIRWAYS, RAMPS AND LANDINGSTHAT ARE LOCATED MORE THAN 30 INCHES ABOVE THE FLOOR OR GRADE BELOW. GUARDS SHALL BE 42INCHES HIGH, MEASURED VERTICALLY ABOVE ADJACENT WALKING SURFACE. GUARDS SHALL HAVEBALUSTERS OR ORNAMENTAL PATTERN SUCH THAT A 4-INCH-DIAMETER SPHERE CANNOT PASS THROUGHANY OPENING.BABY CHANGING TABLE (WHEN PROVIDED)1.BABY CHANGING TABLES WHEN DEPLOYED SHALL NOT OBSTRUCT THE REQUIRED WIDTH OF ANACCESSIBLE ROUTE EXCEPT CAN PROJECT MAXIMUM 4" BETWEEN 27" & 80" ABOVE FINISH FLOOR.CHANGING TABLES SHALL NOT BE LOCATED TOILET COMPARTMENTS THAT ARE WHEELCHAIR ACCESSIBLEWITHIN A MULTIPLE ACCOMMODATION TOILET FACILITY.SANITARY FACILITIES (GENERAL)1.ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32 INCH CLEAR, UNOBSTRUCTEDOPENINGS.2.ALL SINKS, FAUCET CONTROLS, AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND ANDSHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TOACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. LEVER-OPERATED, PUSH TYPE, ANDELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSINGVALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.3.LAVATORIES SHALL BE MOUNTED WITH A MINIMUM DISTANCE OF 18 INCHES FROM A WALL OR PARTITIONTO THE CENTER OF THE FIXTURE. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE FRONT OF THEHIGHER OF THE RIM OR COUNTER SURFACE NO HIGHER THAN 34 INCHES ABOVE THE FLOOR.4.DOORS TO ACCESSIBLE TOILET ROOMS SHALL NOT ENCROACH INTO THE CLEAR FLOOR SPACE REQUIREDFOR ANY FIXTURE.10.A CLEAR SPACE, MEASURED FROM THE FLOOR TO A HEIGHT OF 27 INCHES ABOVE THE FLOOR, WITHIN THESANITARY FACILITY ROOM, OR SUFFICIENT SIZE TO INSCRIBE A CIRCLE OF A DIAMETER NOT LESS THAN 60INCHES, OR A CLEAR SPACE NO LESS THAN 56 INCHES BY 63 INCHES IN SIZE SHALL BE PROVIDED. DOORSOTHER THAN THE DOOR TO THE DISABLED TOILET COMPARTMENT, IN ANY POSITION, MAY NOT ENCROACHINTO THIS SPACE BY MORE THAN 12 INCHES. THIS CLEAR SPACE MAY INCLUDE KNEE AND TOECLEARANCE SPACE UNDER FIXTURES.11.AN ACCESSIBLE INDIVIDUAL TOILET STALL SHALL PROVIDE AT LEAST 59 INCHES CLEAR FLOOR SPACEFROM THE REAR WALL FOR FLOOR MOUNTED WATER CLOSETS AND 56 INCHES CLEAR FLOOR SPACEFROM THE REAR WALL FOR WALL MOUNTED WATER CLOSETS.12.FOR ACCESSIBLE TOILET STALLS WITH DOORS ON THE END WALL, THERE MUST BE 48 INCHES CLEARFROM THE FRONT-MOST POINT OF THE WATER CLOSET. THE SPACE BETWEEN THE CLEAR FLOOR SPACEAND THE 48 INCHES IN FRONT OF THE WATER CLOSET IS CONSIDERED MANEUVERING SPACE. DOORSMAY SWING INTO THE MANEUVERING SPACE.13.FOR ACCESSIBLE TOILET STALLS WITH DOORS ON THE SIDE WALL THERE MUST BE 60 INCHES CLEARFROM THE FRONT-MOST POINT OF THE WATER CLOSET. THE SPACE BETWEEN THE CLEAR FLOOR SPACEAND THE 60 INCHES IN FRONT OF THE WATER CLOSET IS CONSIDERED MANEUVERING SPACE. DOORSMAY SWING INTO THE MANEUVERING SPACE.14.FOR ACCESSIBLE TOILET STALLS WITH IN-SWINING DOORS, THE END WALL MUST BE AT LEAST 36 INCHESBEYOND THE REQUIRED CLEAR FLOOR SPACE.15.WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC CLOSINGDEVICE, AND A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WHEN LOCATED AT THE END AND34 INCHES WHEN LOCATED AT THE SIDE WHEN THE DOOR IS POSITIONED AT AN ANGLE OF 90 DEGREESFROM ITS CLOSED POSITION. DOOR SHALL HAVE A 9 INCH MINIMUM CLEAR OPENING FROM FINISH FLOORTO BOTTOM OF DOOR.16.ACCESSIBLE WATER CLOSET DOOR SHALL BE EQUIPPED ON THE INSIDE AND OUTSIDE WITH HANDLES OFA LOOP OR U-SHAPED DESIGN AND LOCATED IMMEDIATELY ABOVE THE LATCH. THE LATCH SHALL BE AFLIP OVER, SLIDING OR OTHER HARDWARE SO AS NOT TO REQUIRE GRASPING OR TWISTING.17.EXCEPT FOR DOOR OPENINGS, A CLEAR UNOBSTRUCTED ACCESS NOT LESS THAN 44 INCHES SHALL BEPROVIDED TO ALL WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY THE DISABLED.18.TOE CLEARANCE SHALL EXTEND AT LEAST 6" BEYOND AT LEAST ONE SIDE PARTITION OF AN ACCESSIBLETOILET STALL UNLESS THE COMPARTMENT IS GREATER THAN 66 INCHES WIDE. THE UNDERSIDE OF ALLPARTITIONS SHALL BE SMOOTH AND FREE FROM SHARP EDGES OR ABRASIVE SURFACES.TOILET ROOM GRAB BARS1.GRAB BARS SHALL BE LOCATED ON ONE SIDE AND THE BACK OF THE PHYSICALLY DISABLED TOILET STALLOR COMPARTMENT AND SHALL BE SECURELY ATTACHED 33 INCHES MINIMUM AND 36 INCHES MAXIMUMABOVE AND PARALLEL TO THE FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE.2.SIDE GRAB BARS SHALL BE AT LEAST 42 INCHES LONG WITH THE FRONT END POSITIONED AT LEAST 54INCHES FROM THE REAR WALL AND THE BACK END NO LESS THAN 12 INCHES FROM THE REAR WALL.GRAB BARS AT THE BACK STALL SHALL NOT BE LESS THAN 36 INCHES LONG AND EXTEND A MINIMUM OF 12INCHES FROM THE CENTERLINE OF THE WATER CLOSET ON ONE SIDE AND A MINIMUM OF 24 INCHES FROMTHE CENTERLINE OF THE WATER CLOSET ON THE OTHER SIDE.3.THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4 INCHES OR THESHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF THE GRAB BARS ARE MOUNTEDADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL BE 1-1/2 INCHES.4.GRAB BARS AND ANY WALL OR OTHER SURFACE ADJACENT TO THEM SHALL BE FREE OF ANY SHARP ORABRASIVE ELEMENTS.5.GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.6.GRAB BARS SHALL BE DESIGNED TO SUPPORT A 250 POUND FORCE AT ANY POINT.ADDITIONAL REQUIREMENTS1.THE BOTTOM OF RECEPTACLE OUTLET BOXES SHALL BE NOT LESS THAN 15 INCHES ABOVE THE FLOOR2.THE ELECTRICAL BOX OF SWITCHES INTENDED TO BE USED BY OCCUPANTS OF A ROOM OR AREA TOCONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATINGEQUIPMENT, SHALL BE NOT LESS THAN 36 INCHES NOR MORE THAN 48 INCHES (MEASURED TO TOP)ABOVE THE FLOOR OR WORKING PLATFORM.3.THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48 INCHES ABOVE THELEVEL OF THE ADJACENT FLOOR, WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK.4.INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THATARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS.5.THE SYMBOL, SPECIFIED ABOVE, SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUESHALL BE EQUAL TO COLOR NO 15090 IN FEDERAL STANDARD 595A.DISABLED ACCESSIBILITY NOTES AND DETAILS IN DRAWINGSADA-1, ADA-2, AND ADA-3 ARE INTENDED TO SHOW GENERALACCESSIBLE COMPLIANCE AND NOT ALL NOTES OR DETAILSMAY BE APPLICABLE TO THIS PROJECT.REFER TO PROJECT-SPECIFIC PLANS AND SHEETS FOR EXTENTOF WORK REQUIRING COMPLIANCE WITH ACCESSIBILITYREQUIREMENTS.SEE PROJECT-SPECIFIC PLANS AND SHEETS FOR SPECIFICDETAILS AS APPLICABLE.IN NO CASE ARE REQUIREMENTS ON ADA-1, ADA-2, OR ADA-3 TOBE OVER-RIDDEN.ENTRANCES AND DOORS1.ALL PRIMARY ENTRANCES AND EXTERIOR GROUND FLOOR EXIT DOORS TO BUILDINGS AND FACILITIESSHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED.2.ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITHADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS.3.AT ALL TACTILE DOOR SIGNS, A CLEAR FLOOR SPACE AT LEAST 18 INCHES BY 18 INCHES CENTRED ON THESIGN AND CLEAR OF ANY DOOR SWINGS SHALL BE PROVIDED.4.EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT THEINSTALLATION OF A DOOR NOT LESS THAN 36 INCHES IN WIDTH, AND NOT LESS THAN 80 INCHES IN HEIGHT.DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE MOUNTED SO THAT THECLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32 INCHES.5.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED SHALL HAVE A TYPE OF LEVER HARDWARE,PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGEWITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.6.LEVER HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 INCHES AND 44INCHES MAXIMUM ABOVE THE FLOOR.7.THE FLOOR OR LANDING LENGTH ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVELAND CLEAR AT LEAST 60 INCHES IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48 INCHESOPPOSITE THE DIRECTION OF THE DOOR SWING AS MEASURED AT RIGHT ANGLES TO THE FACE OF THEDOOR IN THE CLOSED POSITION. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE WHICH THEDOOR SWINGS SHALL EXTEND A MINIMUM OF 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FORDOORS WITH LATCH SIDE APPROACH AND 36 INCHES FOR DOORS REQUIRING HINGE SIDE APPROACH.REFER TO ACCESSIBLE DETAILS FOR ADDITIONAL CLEARANCE REQUIREMENTS ON SHEET ADA-2.8.THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF THEDOORWAY. CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE LEVELED WITH A SLOPE NOGREATER THAN 1:2.9.THE BOTTOM 10 INCHES OF ALL DOORS (EXCEPT AUTOMATIC AND SLIDING) SHALL HAVE A SMOOTHUNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUTCREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10 INCHHIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR WHICH WILL ALLOW THEDOOR TO BE OPENED BY A WHEELCHAIR FOOTREST.10.THE MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. FOR ALL EXTERIOR AND INTERIORDOORS. SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THECENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOROPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THEMAXIMUM EFFORT TO OPERATE THE DOOR MAY NOT EXCEED 15 LBS.STAIRWAYS1.STAIRWAYS SHALL HAVE INTERMEDIATE HANDRAILS LOCATED IN SUCH A MANNER THAT ALL PORTIONS OFTHE STAIRWAY WIDTH REQUIRED FOR EGRESS CAPACITY ARE WITHIN 30 INCHES OF A HANDRAIL.2.STAIR RISER HEIGHTS SHALL BE 7 INCHES MAXIMUM AND 4 INCHES MINIMUM. THE RISER HEIGHT SHALL BEMEASURED VERTICALLY BETWEEN THE LEADING EDGES OF ADJACENT TREADS. RECTANGULAR TREADDEPTHS SHALL BE 11 INCHES MINIMUM MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OFTHE FOREMOST PROJECTION OF ADJACENT TREADS AND AT RIGHT ANGLE TO THE TREADS LEADING EDGE.3.THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR, AND ALL EXTERIOR STAIRTREADS, SHALL BE MARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE ANDPLACED PARALLEL TO, AND NOT MORE THAN, 1 INCH FROM THE NOSE OF THE STEP OR LANDING TO ALERTTHE VISUALLY IMPAIRED. THE STRIPE SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT ASTHE TREADS OF THE STAIR.4.WHERE STAIRS OCCUR OUTSIDE OF A BUILDING, THE UPPER APPROACH AND ALL TREADS SHALL BEMARKED BY A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2 INCHES WIDE AND PLACED PARALLELTO, AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OR LANDING TO ALERT THE VISUALLYIMPAIRED. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE TREADS OFTHE STAIR. A PAINTED STRIP SHALL BE ACCEPTABLE.5.ALL STAIR TREAD SURFACES SHALL BE SLIP RESISTANT.6.HANDRAILS AT STAIRWAYS SHALL BE 34 INCHES TO 38 INCHES ABOVE THE NOSING OF THE TREADSMEASURED TO THE TOP OF THE HANDRAIL.TOILET ROOM IDENTIFICATION SYMBOLS1.DOOR MOUNTED SIGNAGE1.1.(MEN'S) - EQUILATERAL TRIANGLE 1/4 INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEXPOINTING UPWARD.1.2.(WOMEN'S) - 12 INCH DIAMETER CIRCLE 1/4 INCH THICK.1.3.(UNISEX) - 12 INCH DIAMETER CIRCLE 1/4 INCH THICK WITH 1/4 INCH THICK TRIANGLE SUPERIMPOSEDWITHIN THE CIRCLE.1.4.THE COLOR AND CONTRAST OF THE SIGN DISTINCTLY CONTRASTS WITH THE DOOR COLOR.1.5.SIGNS ARE CENTERED ON THE DOOR 60 INCHES FROM THE FLOOR.2.WALL MOUNTED SIGNAGE2.1.THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS INSTALLED ON THE WALL ADJACENT TO THELATCH SIDE OF THE DOOR. THE BORDER DIMENSIONS OF THIS PICTOGRAM SHALL BE A MINIMUM OF6 INCHES IN HEIGHT. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLELEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THERIGHT.2.2.DESCRIPTION AS TO TOILET ROOM USAGE (I.E. MEN'S TOILET ROOM, ETC.) IS PLACED DIRECTLYBELOW THE SYMBOL OF ACCESSIBILITY.2.3.THE CHARACTERS AND BACKGROUND OF THE SIGN IS EGGSHELL, MATTE, OR OTHER NON-GLAREFINISH AND THE COLOR AND CONTRAST OF THE SIGN DISTINCTLY CONTRASTS WITH THE COLOR ANDCONTRAST OF THE WALL.2.4.SIGNS WITH RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THEFINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST LINE OFBRAILLE AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASUREDFROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. MOUNTING LOCATION SHALLBE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUTENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR.2.5.LETTERS AND NUMERALS ARE RAISED 1/32 INCH, ARE SANS-SERIF UPPERCASE CHARACTERS, ARE AMINIMUM 5/8 INCH HIGH AND A MAXIMUM OF 2 INCHES HIGH, AND ARE ACCOMPANIED BY GRADE 2BRAILLE.TOILET ROOM FIXTURES AND STALLS1.THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUMMEASURED TO THE TOP OF THE SEAT.2.THE CENTER LINE O THE ACCESSIBLE WATER CLOSET SHALL BE 17 INCHES MINIMUM AND 18 INCHESMAXIMUM FROM SIDE WALL OR PARTITION.3.TOILET AND URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BEMOUNTED ON THE OPEN (WIDE) SIDE OF THE TOILET STALL, NO MORE THAN 44 INCHES ABOVE THE FLOOR.THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS.4.WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR SPACE 30 INCHES WIDE BY 48INCHES LONG IN FRONT OF THE URINAL. AT LEAST ONE URINAL WITH A RIM PROJECTING A MINIMUM OF13.5 INCHES FROM THE BACK OF THE FIXTURE AND A MAXIMUM OF 17 INCHES ABOVE THE FLOOR SHALLBE INSTALLED.5.A CLEAR FLOOR SPACE 30 INCHES WIDE BY 48 INCHES LONG SHALL BE PROVIDED IN FRONT OF ALAVATORY TO ALLOW FORWARD APPROACH. SUCH CLEAR SPACE SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE UNDERNEATH LAVATORY.6.LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29 INCHES FROM THE FLOOR TO THEBOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30INCHES IN WIDTH WITH 8 INCHES MINIMUM DEPTH AT THE TOP. TOE CLEARANCE SHALL BE THE SAMEWIDTH AND MINIMUM OF 9 INCHES HIGH FROM THE FLOOR AND A MINIMUM OF 11 INCHES DEEP FROM THEFRONT OF THE LAVATORY.7.HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED.THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.8.MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE REFLECTIVE SURFACE NOT MORE THAN 40INCHES FROM THE FLOOR. LOCATE SOAP DISPENSERS, PAPER TOWEL DISPENSERS, SANITARY NAPKINDISPENSERS AND WASTE RECEPTACLES WITH ALL OPERABLE PARTS NOT MORE THAN 40 INCHES FROMTHE FLOOR.9.TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL 7 INCHES MINIMUM AND 9 INCHES MAXIMUMFROM THE FRONT EDGE OF THE TOILET SEAT. THE DISPENSER OUTLET MUST BE BELOW THE GRAB BARAND 19 INCHES MINIMUM ABOVE THE FLOOR.TOTAL PARKING SPACES PROVIDEDMINIMUM ACCESSIBLE SPACES REQUIRED*1TO 25126TO50251TO75376TO1004101TO1505151TO2006201TO3007301TO4008401TO5009501TO1000 = 2% OF TOTAL1001AND OVER20+ 1 FOR EACH 100, ORFRACTION THEREOF,OVER 10001 MAX.2TRANSITION BETWEEN FLOOR FINISHESLEVEL CHANGES1/4" MAX.19THRESHOLDS AND TRANSITIONS3" = 1'-0"1/2" MAX. PILE HEIGHT THRESHOLDCOMPRESSED CARPET, 1/4" MAX BELOW THRESHOLDFINISHED FLOOR, EVEN HEIGHTTHRESHOLDTHRESHOLD1/4" MAX.1/2" MAX.1 MAX.21/4" MAX.1/2" MAX.CREQUIRED PARKINGBADDITIONAL NOTEDREQUIRED SEATINGFRONT APPROACHES - EXTERIOR DOORS24" MIN. EXTERIOR,18" MIN. INTERIOREXTERIORVESTIBULEINTERIORNOTES:1.CLEAR SPACES MUST BELEVEL TO PREVENTWHEELCHAIRS FROMROLLING WHEN THEOCCUPANT RELEASES THEWHEEL GRIPS TO REACHFOR THE DOOR. 1/4" PERFOOT (1.5%) SLOPE ISALLOWED FOR DRAINAGE.2.WHERE DOORS OPENONTO, BUT NOT INTO ACORRIDOR, THE REQUIREDLEVEL AREA BEYOND THEDOORS MAY BE A MINIMUMOF 48".PULL SIDE12" MIN. IF DOOR HASBOTH A LATCHAND A CLOSER8MANEUVERING CLEARANCES AT DOORS1/4" = 1'-0"60" MIN.DOOR WIDTHPLUS 18" MIN.48" MIN.54" PREFERRED,48" MIN.PUSH SIDEPULL SIDE12" MIN. IF DOOR HASBOTH A LATCHAND A CLOSER60" MIN.DOOR WIDTHPLUS 24" MIN.48" MIN.54" PREFERRED,48" MIN.PUSH SIDE60" MIN.PULL SIDEPUSH SIDE18" MIN.24" MIN.60" MIN.HINGE-SIDE APPROACHES - ALL DOORS36" MIN.DOOR WIDTHPLUS 36" MIN.24" MIN.44" MIN. <br />48" MIN. IF DOOR <br />HAS BOTH A <br />LATCH AND A <br />CLOSER <br />EXTERIORDOORFRONT APPROACHES - INTERIOR DOORSINTERIORDOORPULL SIDE60" MIN.DOOR WIDTHPLUS 24" MIN.24" MIN.PUSH SIDE60" MIN.24" MIN.44" MIN. <br />48" MIN. IF DOOR <br />HAS BOTH A <br />LATCH AND A <br />CLOSER <br />LATCH-SIDE APPROACHES - ALL DOORSRAMP LANDING AT DOOR60" MIN.RAMPPULL SIDE42" MIN.60" MIN.RAMPPUSH SIDE60" MIN.12" MIN. IF DOOR HASBOTH A LATCHAND A CLOSERDOORS AT ENTRANCE VESTIBULE48" MIN.12" MIN.18" MIN.48" MIN.48" MIN.12" MIN.34" CLR.24" MIN.ACCESSIBILITYSIGN ON STRIKESIDE OF DOOR,MOUNTED ONWALL ORSIDELITEEXITINSIDE VIEW - SINGLE DOORDOOR NOTES:BOTTOM RAIL:A.MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, EITHER ATTACHED PANEL OR BOTTOM RAIL.HARDWARE:A.OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT.B.OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT REQUIRING GRASPING) MOUNTED 34" TO 44" A.F.F.C.MAXIMUM 5 LBS. EFFORT TO OPERATE EXTERIOR DOOR, 5 LBS. FOR INTERIOR DOORS.SIGNAGE:A.MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN SWING OF DOOR.B.IF ACCESSIBILITY OR EXIT SIGN OCCURS ON SIDELITE, PLACE A MATCHING OR BLANK PANEL ON OPPOSITE SIDE.C.SIGNS WITH RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE BASELINE OF THE LOWEST LINE OF BRAILLE AND 60INCHES MAXIMUM MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS.EXIT SIGN NOTES:LETTERS/NUMERALS SHALL BE RAISED 1/32", UPPER CASE SANS SERIF TYPE ON CLEAR PHOTOPOLYMERPLAQUE AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST5/8" HIGH, BUT NO HIGHER THAN 2".INTERNATIONAL SYMBOLOF ACCESSIBILITYENTRANCE SIGN (PLACED ONEXTERIOR OF BUILDING)EXIT SIGN (PLACED ONINTERIOR OF BUILDING)6"6"LETTERINGRAISE 1/32"CORRESPONDINGGRADE 2 BRAILLEMIN. 3/8", <br />MAX. 1/2" <br />0.200" O.C.0.100" O.C. INTERDOT SPACING0.100" O.C.0.200" O.C. INTERCELL SPACING0.025" <br />HEIGHT0.059" DIA.7ACCESSIBILE ENTRANCES AND SIGNAGE3/16" = 1'-0"GRADE 2 BRAILLE STANDARD DIMENSIONS:DOT BASE DIAMETER .059"DOT HEIGHT (ROUNDED ON TOP) .025"DOT SPACING WITHIN THE SAME CELL.10" O.C.DOT SPACING BETWEEN CELLS.20" O.C.ALL TACTILE EXIT SIGNS ARE IN ADDITION TO ILLUMINATED EXIT SIGNS. AT WALLS SECURE SIGN WITH VINYLFOAM TAPE. AT STOREFRONT LOCATIONS ATTACH SIGN TO GLASS WITH MASTIC CLEAR DOUBLE FACEDTAPE AND BEHIND THE SIGN MOUNT A FROSTED VINYL SHAPE OF SAME CONFIGURATION AS SIGN ONEXTERIOR FACE OF GLASS TO EXACTLY ALIGN WITH SIGN.EXIT48" MIN.60" MAX. <br />10" MIN.3" MIN.OUTSIDE VIEW - SINGLE DOOR60" AFFCENTER SIGN10" MIN.SIDELITE WHERE OCCURSEXIT SIGN WITH BOTH TACTILE ANDBRAILLE LETTERS ON STRIKE SIDE OFDOORS ON WALL OR SIDELITE10" MIN.ACCESSIBILITYSIGN ON STRIKESIDE OF DOOR,MOUNTED ONWALL ORSIDELITE60" AFF <br />CENTER SIGN SIDELITE WHERE OCCURSEXIT SIGN WITH BOTH TACTILE ANDBRAILLE LETTERS ON RIGHT SIDE OFDOORS ON WALL OR SIDELITEOUTSIDE VIEW - PAIR OF DOORSEXIT10" MIN.3" MIN.48" MIN. <br />60" MAX.INSIDE VIEW - PAIR OF DOORS5% OF SEATING AND STANDING SPACES AT DINING SURFACES SHALL BE ACCESSIBLE. REFER TO FIXTUREPLAN, DWG. A-1.1 FOR DISBURSEMENT OF ACCESSIBLE SEATING.TOTAL NUMBER OF SEATSMINIMUM ACCESSIBLE SEATS REQUIRED1TO 20121TO40241TO60361TO80481TO1005101TO1206121TO1407141TO1608161TO1809181TO20010*FOR EVERY SIX OR FRACTION OF SIX ACCESSIBLE PARKINGSPACES, AT LEAST ONE SHALL BE "VAN ACCESSIBLE".REVISIONSALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH, THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF PROJECT ARCHITECT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR, ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED.W:\Data\Golden Gate Bell\21036_GGB_Tracy_STracyBlvd_30810\03_cd\_current\011_21036_ADA-1.dwg By: DHAMMOND Saved on:10/26/2021 11:11:18 AM <br />RECORD DATESDD SUBMITTALBLDG. SUBMITTALBID SETCONTRACT SET-07/02/2021-VMI JOB NUMBER21036CLIENTGOLDEN GATE BELL3120 S. DURANGO DRIVELAS VEGAS, NV 89117Contact: Chris Czyz, (602) 714-3099SITE #30810PROJECTTACO BELL REMODEL915 S. TRACY BLVD.TRACY, CA. 95376APN #TBDENDEAVORSUCCESSOR637 5th Avenue San Rafael, CA 94901415-451-2500 415-451-2595 faxwww.vmarchitecture.comDesign ~ Planning ~ InteriorsN <br />IATAFOCTEOFLIRS L <br />TCEDDNo. C17928REN. 10/31/23UGHH <br />A MYHPURRRWDEAAI <br />E <br />C <br />NSECHTIADA-1ACCESSIBILITYENTRANCEDETAILS