REFRIGERATION SCHEDULERS <br />RM <br />C FURNISHED AND INSTALLED BY REFRIG. CONTRACTOR. <br />FURNISHED AND INSTALLED BY RACK MANUFACTURER. <br />CM FURNISHED AND INSTALLED BY CASE/COIL MANUFACTURER. <br />RMC <br />CMC <br />FURNISHED BY RACK MANUFACTURER, INSTALLED BY REFRIGERATION CONTRACTOR. <br />FURNISHED BY CASE/COIL MANUFACTURER, INSTALLED BY REFRIGERATION CONTRACTOR. <br />LEGEND *REFRIG. LINE ROUTE **DEFROST TYPE <br />E <br />N <br />R <br />S <br />U <br />EXISTING <br />NEW <br />RELOCATE <br />SURPLUS <br />USED <br />U/O <br />O.H. <br />M <br />B <br />OVERHEAD W/ <br />OVERHEAD <br />MAIN <br />BRANCH <br />TRENCH <br />PORTION IN <br />(2-PIPE) <br />TO <br />EL <br />HG <br />ELECTRIC DEFROST <br />HOT GAS DEFROST <br />TIME OFF DEFROST1" <br />1/2" <br />3/4" <br />INSULATION FOR REFRIGERANT LINES ARMAFLEX OR <br />RUBATEX <br />MED. TEMP <br />(SUCTION) <br />LOW TEMP <br />(SUCTION) <br />MED & LOW <br />TEMP <br />(LIQUID) <br />X <br />X <br />HEAT <br />RECLAIM <br />DISCHARGE <br />LINE <br />NOTE: INSULATION VALUES SHOWN ARE TYPICAL. <br />X X <br />1. REFRIGERATION CONTRACTOR TO INSTALL 18" X 24" PLANS ON THE WALL NEAR SYSTEM, (1) EACH FOR R-1, R-2 & R-3. <br />SECURE NEAR SYSTEM WHERE PLANS CAN EASILY BE READ. COVER PLANS W/ 1/8" PLEXI-GLASS FOR PROTECTION. <br />CONTACT ARCHITECT OF RECORD FOR CLEAN SET OF PLANS. <br />2. HIGH PRESSURE CONTROL SETTINGS FOR R-448A AT 344 Ibs FOR PARALLEL SYSTEMS. REFRIGERATION CONTRACTOR TO <br />CHECK AND ADJUST DURING SYSTEM START UP. <br />3. REFRIGERATION CONTRACTOR TO FIELD INSTALL SYSTEM SHIPPED LOOSE ITEMS, BALL VALVES, CHECK VALVES, <br />STRAINERS, ETC.. <br />4. REFER TO REFRIGERATION SPECIFICATIONS AND EQUIPMENT MANUALS FOR INSTALLATION, TESTING, AND START-UP <br />INFORMATION. <br />HUSSMANN SINGLE CONDENSING UNITS (OUTDOOR) <br />CONDENSING UNIT TO BE FURNISHED W/ THE FOLLOWING: <br />1.COPELAND COMPRESSOR. (RE:SCHEDULE FOR MODEL) <br />2.CONTROLS FOR LOW & HIGH OIL PRESSURE. <br />3.PARAGON TIMECLOCK FOR DEFROST, OR EQUIVALENT. <br />4.VERTICAL RECEIVER (AS REQUIRED) <br />5.SUCTION FILTER & LIQUID DRIER. <br />6.SUCTION ACCUMULATOR. <br />7.CONTROL PANEL CONTAINING COMPRESSOR & DEFROST BREAKERS & CONTACTORS. <br />(RE:SCHEDULE FOR SIZING) <br />8.VIBRATION ELIMINATORS, DISCHARGE MUFFLERS, & SUCTION ACCUMULATORS. <br />9.SHIP LOOSE LIQUID SOLENOID & T-STAT (RE:SCHEDULE) <br />COILS <br />KRACK COOLER/FREEZER COILS <br />(RE:SCHEDULE FOR MODEL NUMBERS). <br />COILS TO BE FURNISHED WITH THE FOLLOWING: <br />1.ALCO, DANFOSS, OR SPORLAN THERMAL EXPANSION VALVES. <br />2. EC MOTORS <br />REFRIGERANT (RE: SCHEDULE) <br />CASES <br />(RE:SCHEDULE FOR MODEL NUMBERS). <br />CASES TO BE FURNISHED WITH THE FOLLOWING: <br />1.ALCO, DANFOSS, OR SPORLAN THERMAL EXPANSION VALVES. <br />2.ALCO ALLS PRESSURE STABILIZERS OR EQUIVALENT HEAT EXCHANGER <br />EC MOTORS, OR EQUIVALENT <br />THE CONTRACTOR IS TO PROVIDE, BUT NOT LIMITED TO, THE FOLLOWING. REFER TO THE <br />REFRIGERATION SPECIFICATIONS FOR MORE INFORMATION. <br />REFRIGERATION INSULATION (RE:SCHEDULE FOR SIZE) <br />REFRIGERANT PIPING <br />1.BETWEEN EVAPORATORS AND CONDENSING UNITS. <br />2.BETWEEN COILS. <br />FURNISHED BY REF. CONTRACTOR <br />FURNISHED BY OWNER <br />EQUIPMENT SCHEDULE AND SPECIFICATIONS SCHEDULE OF GENERAL NOTES <br />ABBREVATIONS <br />INSTALLATION CODE <br />LEGEND AND REMARKS <br />REMOTE REFRIGERATION CASES / EVAPORATOR COILS DISTRIBUTED COOLING DESIGN REFRIGERANT PIPING CASE / COIL ELECTRICAL REQUIREMENTS <br />CONDENSING UNIT REFERENCE NUMBERCOMPRESSOR/CONDENSING UNIT CONDENSING UNIT <br />ELECTRICAL <br />REMARKS <br />SYSTEMREFERENCENUMBERFIXTUREREFERENCEDESIGNATIONSFIXTURE <br />DESCRIPTION <br />CASE AND <br />COOLER SIZE <br />MANUFACTURER, <br />QUANTITY, <br />AND MODEL NO. <br />RE: MANUFACTURERS <br />LEGEND DEFROSTTYPEDESIGN EVAPORATORTEMPERATURE °FDISCHARGE AIRTEMPERATURE °FRACK (OR CU) SUCTIONTEMPERATURE °FMBH REQUIREMENTSFOR COOLER OR CASESTOTAL MBHREQUIREMENTSCOIL DESIGN TD °FCOIL ACTUAL TD °FSUCTION PIPINGSUCTION RISER PIPINGLIQUID PIPINGSYSTEMREFERENCENUMBERCASE / COIL FAN MOTOR AMPS <br />(115 V FROM STORE PANEL) <br />CASE & CANOPY LIGHTS <br />(115 V FROM STORE PANEL)CASE DEFROST (208V-1Ø OR 3Ø FROM RACK PANEL) <br />WALK IN COIL FAN AMPS <br />(208-1-60 FROM CONDENSING UNIT <br />PANEL) <br />WALK-IN EL DEFROST <br />(208-1-60 FROM <br />COND UNIT PANEL) <br />DEFROST CONTROL <br />(FED FROM CU PANEL)RMC RMC CMC RMC CM ELECTRICAL <br />CONDENSING UNIT SUCTIONTEMPERATURE °FCOMPRESSOR <br />MODEL NO.COMPRESSOR UNITHORSEPOWERCONDENSING UNITCAPACITY @ 105F AMB (MBH)REFRIGERANTDESIGN AMBIENT TEMPERATURE °FRECEIVER CAPACITY (LBS)MCA @ 208-230/3/60MOP @ 208-230/3/60MOPDNO. OTHER CASESNO. OTHER CASESNO. 8' CASESNO. 12' CASESTOTAL LENGTH (OR DR QTY)AMPS PEROTHER CASEAMPS PER8' CASEAMPS PER12' CASETOTAL AMPS PERSYSTEM BY CIRCUITAMPS PEROTHER CASEAMPS PER8' CASEAMPS PER12' CASETOTAL AMPS PERSYSTEM BY CIRCUIT AMPS PER OTHER CASE AMPS PER OTHER CASEAMPS PER8' CASEAMPS PER12' CASETOTAL AMPS PERSYSTEM BY CIRCUITPHASENO. OF COILSFAN AMPSPER COILTOTAL FAN AMPSPER SYSTEMVOLTAGE/PHASECOIL DEFROST AMPS(PER COIL)TOTAL AMPS DEFROSTVOLTAGE/PHASEMIN 208V CIRCUITAMPERES (1 phase)DEFROST&CONTROLMAIN BREAKERLIQUID AND ISOLATION BALLVALVESLIQUID LINE SOLENOID (208V)INSTALLED AT CU.HEAT EXCHANGERTHERMOSTAT (208V)THERMALEXPANSION VALVENO. OF CONTROL WIRESLIQUID LINE SOLENOID (208V)NO. CONTROL WIRES DEFROSTTERMINATION VIA KLIXONWIRING DIAGRAM REFERENCENUMBERCIRCUIT REFERENCE NUMBERCONDENSING UNIT MODEL NO. <br />amps Ø amps Ø amps Ø amps Ø <br />A1 FRZR REACH IN FF/IC 2DR 6DK CASE 1 2 HUSS 1 RLTM EL -20 -12 -23 2.3 2.3 5/8 1/2 1/2 A1 2.96 3.0 0.36 0.4 6.72 1PH 6.7 1PH 20-2P ••••2 2 R6-2 A1 CU1 -23 <br />TECUMSEH ARGUS OUTDOOR CONDENSING <br />UNIT <br />MODEL - ASHR2460ZFAFG1 <br />TECUMSEH AWA2450 <br />WEIGHT = 196LBS <br />DIMENSION = 28.4"L x 28.4"W x 18"H <br />MOUNTING HOLE DIM = 27.6"L x 23.9"W <br />1-1/2 2.7 R448A 105 8.5 <br />REFRIGERATION CONTRACTOR <br />TO FIELD INSTALL LSOLs AT <br />CONDENSING UNITS. <br />INNOVATOR DRS <br />EL CONTRACTOR TO FIELD INSTALL THE DEFROST <br />BREAKER/CONTACTOR FOR EL DEFROST CIRCUIT <br />7.7 13.5 20 <br />A2 BEER-BEV <br />COOLER <br />BEVERAGE/BEER COOLER W/ 14 DISPLAY DRS <br />1/4 COOLER BOX 432 SQ FT KRACK 1 GLD36A-135-TDB TO +25 +35 +23 12.4 12.4 10.0 9.3 7/8 3/4 1/2 A2 2.7 2.7 •••••2 R6-1 A2 CU2 +23 <br />TECUMSEH ARGUS OUTDOOR CONDENSING <br />UNIT <br />MODEL - ASHR9512ZFAFG1 <br />TECUMSEH AWA9512 <br />WEIGHT = 234LBS <br />DIMENSION = 39.9"L x 28.5"W x 21.5"H <br />MOUNTING HOLE DIM = 39.1"L x 25.2"W <br />1-1/2 12.8 R448A 105 23.3 10.6 18.3 20 <br />CUs TO HAVE FACTORY <br />INSTALLED TIME CLOCK AND <br />RECEIVER HEATER. LSOL <br />SHIPPED LOOSE. <br />A3 BEER-BEV <br />COOLER <br />BEVERAGE/BEER COOLER W/ 14 DISPLAY DRS <br />1/4 COOLER BOX 432 SQ FT KRACK 1 GLD36A-135-TDB TO +25 +35 +23 12.4 12.4 10.0 9.3 7/8 3/4 1/2 A3 2.7 2.7 •••••2 R6-1 A3 CU3 +23 <br />TECUMSEH ARGUS OUTDOOR CONDENSING <br />UNIT <br />MODEL - ASHR9512ZFAFG1 <br />TECUMSEH AWA9512 <br />WEIGHT = 234LBS <br />DIMENSION = 39.9"L x 28.5"W x 21.5"H <br />MOUNTING HOLE DIM = 39.1"L x 25.2"W <br />1-1/2 12.8 R448A 105 23.3 10.6 18.3 20 <br />A4 BEER-BEV <br />COOLER <br />BEVERAGE/BEER COOLER W/ 14 DISPLAY DRS <br />1/4 COOLER BOX 432 SQ FT KRACK 1 GLD36A-135-TDB TO +25 +35 +23 12.4 12.4 10.0 9.3 7/8 3/4 1/2 A4 2.7 2.7 •••••2 R6-1 A4 CU4 +23 <br />TECUMSEH ARGUS OUTDOOR CONDENSING <br />UNIT <br />MODEL - ASHR9512ZFAFG1 <br />TECUMSEH AWA9512 <br />WEIGHT = 234LBS <br />DIMENSION = 39.9"L x 28.5"W x 21.5"H <br />MOUNTING HOLE DIM = 39.1"L x 25.2"W <br />1-1/2 12.8 R448A 105 23.3 10.6 18.3 20 <br />A5 BEER-BEV <br />COOLER <br />BEVERAGE/BEER COOLER W/ 14 DISPLAY DRS <br />1/4 COOLER BOX 432 SQ FT KRACK 1 GLD36A-135-TDB TO +25 +35 +23 12.4 12.4 10.0 9.3 7/8 3/4 1/2 A5 2.7 2.7 •••••2 R6-1 A5 CU5 +23 <br />TECUMSEH ARGUS OUTDOOR CONDENSING <br />UNIT <br />MODEL - ASHR9512ZFAFG1 <br />TECUMSEH AWA9512 <br />WEIGHT = 234LBS <br />DIMENSION = 39.9"L x 28.5"W x 21.5"H <br />MOUNTING HOLE DIM = 39.1"L x 25.2"W <br />1-1/2 12.8 R448A 105 23.3 10.6 18.3 20 <br />A6 ISL-1 GRAB-N-GO ISLE MERCHANDISER - END CASE 2 8 HUSS 1 IM-05-E4-R TO +25 +32 +23 10.6 10.6 7/8 5/8 1/2 A6 0.3 0.3 0.6 0.6 ••••2 R6-3 A4 CU6 +23 <br />TECUMSEH ARGUS OUTDOOR CONDENSING <br />UNIT <br />MODEL - ASHR9512ZFAFG1 <br />TECUMSEH AWA9512 <br />WEIGHT = 234LBS <br />DIMENSION = 39.9"L x 28.5"W x 21.5"H <br />MOUNTING HOLE DIM = 39.1"L x 25.2"W <br />1-1/2 12.4 R448A 105 23.3 10.6 18.3 20 <br />SC1 SELF <br />CONTAINED ICEE SLUSH BEVERAGE DISPENSER ICEE RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC1 <br />REFRIGERATION CONTRACTOR TO INSTALL SELF-CONTAINED FIXTURES. <br />ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL REQUIREMENTS AND <br />INSTALL ELECTRICAL AS REQUIRED. PLUMBING CONTRACTOR TO <br />VERIFY CONDENSATE DRAIN REQUIREMENTS AND INSTALL AS <br />REQUIRED. <br />SC2 SELF <br />CONTAINED ICEE SLUSH BEVERAGE DISPENSER ICEE <br />561-ID ICEE RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC2 <br />SC3 SELF <br />CONTAINED ICEE SLUSH BEVERAGE DISPENSER ICEE <br />774-ID ICEE RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC3 <br />SC4 SELF <br />CONTAINED ICE DRINK BEVERAGE DISPENSER CORNELIUS 621058656 COR RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC4 <br />SC5 SELF <br />CONTAINED SCOTSMAN ICE NUGGET MACHINE N0622/N0622A-1 SCOT RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC5 <br />SC6 SELF <br />CONTAINED MILK SHAKE MAKER F'REAL <br />FRE B6 RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC6 <br />SC7 SELF <br />CONTAINED TWO 4' REFRIGERATED WORK TABLE RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC7 <br />SC8 SELF <br />CONTAINED 300LB SC CUBER ICE MACHINE WITH STORAGE SCOTSMAN <br />CU3030/CU3030MA-1 SCOT RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC8 <br />SC9 SELF <br />CONTAINED TRAULSEN 3DR UPRIGHT FREEZER TRA G31310 TRA RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC9 <br />SC10 SELF <br />CONTAINED GENERIC ICE CHEST LEER RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC10 <br />SC11 SELF <br />CONTAINED SOFT SERVE COUNTER TOP STO E131 STO RE: MANUFACTURER CUTSHEETS FOR ELECTRICAL REQUIREMENTS SC11 <br />DESIGN CONDITIONS <br />ELECTRICAL <br />SERVICE OUTSIDE DESIGN INSIDE DESIGN ELEVATION <br />DB WB <br />208 V ASHRAE AMBIENT USE 105.0°F DRY BULB 75.0°F STORE ELEVATION 82 FT <br />3 PH RELATIVE HUMIDITY 55%CORRECTION FOR ELEVATION 1.00 <br />60 HZ ASHRAE STATION DRY BULB 101.1°F (FOR AIR-COOLED CONDENSERS) <br />724290 WET BULB 73.2°F <br />WINTER 30.3°F <br />REGISTEREDP R O F E S SION <br />A <br />L <br />E <br />NGI <br />NEERJAR E D H .MIL <br />L <br />E <br />RST <br />A <br />TEOF C A L I F O R N IAM <br />ECHA N I C A LProject:21STAN01Phone: 208.288.2181 <br />SHEET TITLE <br />SHEET NO. <br />SUBMITTAL <br />CAD SAVED NAME: <br />PROJECT NO. <br />DRAWN BY: <br />CHECKED BY: <br />OWNER: 21.03.19 <br />BUILDING DEPT: 21.05.14 <br />O.T.B.: <br />DATES <br />REVISIONS: <br />DATE#REVISION BY <br />SAFEWAY FUEL CENTER #005519533 S. MOUNTAIN HOUSE PKWY.MOUNTAIN HOUSE, CA 953812007730004 <br />--www.stantec.comTEL. 1383 North McDowell Blvd. Suite 250Petaluma, CA 94954707.765.1660Architecture Inc.- <br />05 / 17 / 2021 <br />R4 <br />REFRIGERATION <br />SCHEDULES