R6 <br />0 <br />0R600MYO 2X MYO 2X <br />MYO 3X MYO 3X <br />ROOF JOISTS <br />SHOWN DASHED, <br />TYP <br />RE: GENERAL <br />NOTES FOR <br />MOUNTING INFO <br />MONOPOINT FOR <br />DECOR, RE: <br />INTERIORS DWGS <br />ALIGN OUTSIDE EDGE <br />OF MYO FIXTURES <br />MOUNT CLX FIXTURES <br />TIGHT TO BOTTOM OF <br />JOISTS, TYP <br />MONOPOINT FOR <br />"BOTTLECAP," RE: <br />INTERIORS DWGS <br />SUSPENDED HARD <br />LID, RE: ARCH & <br />INTERIORS DWGS <br />~ <br />FINISHED FLOOR <br />DIMMING SWITCH BANK ELEVATION <br />(e) <br />REGISTER <br />AREA <br />SERVICE <br />AREA <br />(d1,d2) <br />DAYLIGHT <br />LIGHTINGAREA <br />STOCK <br />NORTH <br />SOUTH <br />WEST EAST <br />1 ELECTRICAL LIGHTING FLOOR PLAN SCALE: 1/4" = 1'-0" <br />A.PRIOR TO ROUGH-IN, THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE <br />EXACT LOCATION OF ALL LIGHT FIXTURES / EXIT SIGN LOCATION / PLACEMENT <br />WITH THE CITY OF STAR FIELD BUILDING INSPECTOR PRIOR TO ROUGH <br />INSPECTION APPROVAL: ALL CONFLICTS SHALL BE REPORTED TO THE <br />ENGINEER/ARCHITECT. <br />B.ALL FIXTURES INSTALLED OUTDOORS SHALL BE RATED FOR DAMP/WET <br />LOCATIONS AS REQUIRED. THE CONTRACTOR SHALL COORDINATE DAMP/WET <br />LOCATION RATING PER CEC ARTICLE 410.10(A). ALL INSTALLATIONS SHALL <br />CONFORM TO CEC ARTICLE 410, ALL SUB ARTICLES. <br />C.PROVIDE EXIT SIGNS FOR ALL EXITS DESIGNATED BY THE CODE STUDY PLAN. <br />REFER TO ARCHITECTURAL CODE PLANS FOR LOCATIONS AND <br />REQUIREMENTS. <br />D.ALL EXIT AND EMERGENCY LIGHTS SHALL BE CONNECTED TO UNSWITCHED <br />CIRCUIT LEG AHEAD OF ALL SWITCHES/CONTACTORS/RELAYS. <br />E.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION <br />OF ALL LIGHT FIXTURES. VERIFY EXACT LOCATION OF ALL WALL MOUNTED <br />LIGHT FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN. <br />F.VERIFY EXACT MOUNTING HEIGHT OF ALL WALL MOUNTED LIGHT FIXTURES <br />WITH ARCHITECT PRIOR TO ROUGH-IN. <br />G.VERIFY EXACT MOUNTING HEIGHT OF EXTERIOR LIGHT FIXTURES WITH <br />ARCHITECTURAL EXTERIOR ELEVATIONS. <br />H.ALL LIGHTING FIXTURES TO BE PROVIDED BY OWNER AND INSTALLED BY <br />ELECTRICAL CONTRACTOR. <br />I.IT IS ASSUMED THAT ANY OUTLET, SWITCH, RECEPTACLE, DEVICE, FIXTURE <br />OR PANEL MAY BE RELOCATED WITHIN A TEN (10) FOOT RADIUS OF THE <br />INDICATED LOCATION WITHOUT ADDITIONAL CHARGE TO THE OWNER. <br />J.CONDUIT AND WIRING SHOWN FOR REFERENCE ONLY. IT IS THE <br />RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE THE NUMBER <br />OF CONDUCTORS REQUIRED FOR HOT-LEGS, NEUTRAL, AND GROUNDING AT <br />EACH DEVICE FOR PROPER BRANCH CIRCUITING SHOWN FOR EACH AREA OR <br />ROOM. <br />1.THE ELECTRICAL CONTRACTOR TO PROVIDE LOCAL ACUITY SENSOR SWITCH <br />WST PDT WH WALL MOUNTED OCCUPANCY SENSOR. ELECTRICAL <br />CONTRACTOR TO FIELD VERIFY FINAL LOCATION PRIOR TO ROUGH-IN. <br />2.LINE DENOTING FROM THE VERTICAL GLAZING FOR DAYLIGHT ZONE. <br />3.CEILING MOUNTED EMERGENCY EGRESS LIGHT. ELECTRICAL CONTRACTOR <br />SHALL FIELD VERIFY FINAL LOCATION PRIOR TO ROUGH-IN. <br />4.PROVIDE LOCAL LIGHTING SWITCHES (TYPICAL OF 4). VERIFY EXACT <br />REQUIREMENTS WITH OWNER AT JOBSITE. <br />5.DAYLIGHT BOUNDARY PHOTOCELL: ELECTRICAL CONTRACTOR TO <br />COORDINATE WITH AXIOM EMS AND PROVIDE DAYLIGHT PHOTOCELL SENSOR <br />TO DETECT NATURAL SUNLIGHT AND AUTOMATICALLY DIM ALL GENERAL <br />LIGHTING WITHIN ITS SPECIFIC BOUNDARY. COORDINATE WITH AXIOM EMS <br />FOR COMPLETE REQUIREMENTS AND CONTROLS. <br />6.TIMECLOCK FOR LIGHTING CONTROLS AND CONTACTORS, ELECTRICAL <br />CONTRACTOR TO COORDINATE WITH POWER INTEGRITY FOR ANY APPLICABLE <br />REQUIREMENTS AND ENSURE TO PROVIDE AS APPLICABLE FOR A COMPLETE <br />AND FUNCTIONAL INSTALLATION PRIOR TO INSTALLATION. <br />7.PROVIDE LIGHTING SWITCH BANK (IN A FLUSH MOUNTED BOX WITH <br />CONCEALED CONDUITS) SEE DETAIL PER THIS SHEET. COORDINATE LOCATION <br />WITH OWNERS REPRESENTATIVE PRIOR TO INSTALLATION. <br />8.PROVIDE FIXTURE AS A NIGHT LIGHT (UNSWITCHED) FOR CONTINUOUS ON <br />OPERATION. <br />9.PROVIDE AN UNSWITCHED PHASE "HOT' CONDUCTOR AND CIRCUIT THROUGH <br />EMERGENCY INVERTER(S). PROVIDE 2#12 & #12 GR. IN 3/4" CONDUIT TO <br />EMERGENCY INVERTERS FOR CONTINUOUS CHARGING. PROVIDE ACUITY EAC <br />ISSM TYPE INVERTER AND FIELD COORDINATE LOCATION WITH OWNERS <br />REPRESENTATIVE PRIOR TO ROUGH-IN. <br />10.INVERTERS TO PROVIDE EMERGENCY LIGHTING POWER UPON LOSS OF <br />NORMAL POWER. MOUNT INVERTER ABOVE ACCESSIBLE CEILING AND WIRE TO <br />CIRCUIT INDICATED AHEAD OF ANY CONTROLS. PROVIDE ACUITY EAC IIS 125 <br />SM TYPE INVERTER. <br />11.CIRCUIT THROUGH PHOTOCELL ON/TIMECLOCK OFF. <br />12.PROVIDE MOTION SENSING CONTROLS PER CALIFORNIA BUILDING ENERGY <br />EFFICIENCY STANDARDS SECTION 130.2(c)3. <br />(DANFOSS PHOTOCELLS) PHOTOSENSOR <br />FOR DAYLIGHT ZONE SHALL <br />AUTOMATICALLY ADJUST THE LIGHT <br />OUTPUT OF ALL CONNECTED LUMINAIRES <br />BASED ON THE DAYLIGHT LEVEL IN THE <br />SPACE. <br />TOGGLE SWITCH FOR MANUAL ON/OFF <br />LIGHTING CONTROL. SUBSCRIPT <br />INDICATES WHICH FIXTURES ARE TO BE <br />CONTROLLED BY WHICH SWITCH. <br />(ACUITY CONTROLS: CMR PDT9)CEILING <br />MOUNT LINE VOLTAGE DUAL <br />TECHNOLOGY SENSOR, EXTEDED RANGE <br />360 COVERAGE. <br />(ACUITY CONTROLS: WSD-SA-WH) <br />SWITCHES LABELED 'OS' SHALL TURN <br />OFF ALL CONNECTED LUMINAIRES <br />WITHIN 30 MINUTES OF SPACE BEING <br />VACANT. <br />AUTO DIMMING <br />CEILING SENSOR <br />LINE VOLTAGE <br />CEILING SENSOR <br />LIGHTING CONTROL DEVICE SCHEDULE <br />GENERIC <br />SWITCH <br />OCCUPANCY <br />SENSOR <br />KEYED NOTES <br />LIGHTING GENERAL NOTES <br />SHEET TITLE <br />SHEET NO. <br />SUBMITTAL <br />O.T.B.: <br />DATES <br />REVISIONS: <br />DATE#REVISION BY <br />www.stantec.comTEL. 1383 North McDowell Blvd. Suite 250Petaluma, CA 94954707.765.1660Architecture Inc.R <br />ENGINEERING, INC <br />OBISON <br />19401 40TH AVE W., SUITE 302 <br />LYNNWOOD, WA 98036 <br />206-364-3343 tel <br />CONTACT: MARK MANGLICMOT <br />5/14/21 <br />E1.0 <br />OWNER: 21.03.19 <br />BUILDING DEPT: <br />CAD SAVED NAME: <br />PROJECT NO. <br />DRAWN BY: <br />CHECKED BY: <br />2007730004 <br />ELECTRICAL <br />LIGHTING FLOOR <br />PLAN